Fri Jan 28 11:33:40 2011 No variables in Alarm for family: CHCURRAVERAGE No variables in Alarm for family: CHDISTAVERAGE No variables in Alarm for family: CHINTCONTROLCURRENT Fam: CHDISTRMS in Alarm over indexes: * No variables in Alarm for family: CHCURRRMS No variables in Alarm for family: MODES No variables in Alarm for family: CHNEWDELTACOMMAND No variables in Alarm for family: CHFFCOMMAND No variables in Alarm for family: CHFFPURECURRENT Adam watchdog not expired. Ethernet connection watchdog on Switch BCU not expired. Ethernet connection watchdog on Crate BCU not expired. Watchdog expired for DSP ID: 040 041 042 043(#004)- Consider the dsp boards replacement Distance theshold check passed with no issues found. Temperature check passed with no issues found. OVERCURRENT probability for TOTAL PUSH CURRENT: 0.0% OVERCURRENT probability for TOTAL PULL CURRENT: 0.0% OVERCURRENT probability for SINGLE CRATE TOTAL CURRENT: 0.0%

The board 6-7 (from 0) crate 1 has to be substituted with a new one (MX)(SN:245,142 to double check)

-- MarcoXompero - 28 Jan 2011
Topic revision: r3 - 07 Mar 2011, ArmandoRiccardi