"Retracted swing-arm" detected by error (false detection)
the false detection caused a RIP of the shell
adsecarb.R |ERR| 36764|2010-10-19 01:18:33.449487| MAIN > Swing arm not deployed! Resting the shell.
adsecarb.R |INF| 36765|2010-10-19 01:18:33.697344| COMMANDHANDLER > forceRest(): disabling coils
again later:
adsecarb.R |ERR| 44653|2010-10-19 07:37:39.441390| MAIN > Swing arm not deployed! Resting the shell.
adsecarb.R |INF| 44654|2010-10-19 07:37:39.679100| COMMANDHANDLER > forceRest(): disabling coils
It requires investigation on the source of the missing variable. Where the connection was lost? AOS? OSS?
AdSecArb?
--