Late start because clouds.
Open dome at about 9:15 UT
Collimated with Z5=-30.65 and Z6=+79.936
Closed loop short time before 2010-06-26 07:50:20.851562
Rip:
FASTDGN00 |ERR| 3280258|2010-06-26 07:51:29.719115| FUNCTEMERGENCYST > CHCURRAVERAGE-0028 = 0.8 [/home/aoacct/releases/src2/DiagnApp/Funct.h:248]
FASTDGN00 |INF| 3280259|2010-06-26 07:51:29.719189| ADAM > Adam: disabling coils...
FASTDGN00 |INF| 3280260|2010-06-26 07:51:29.719944| ADAM > Adam: coils succesfully disabled
set and flat
2010-06-26 07:56:29.605335 reacquiring the star:
bad coma, trying another flattenning command for ASM
2010-06-26 08:06:06.701965 collimation reached the range limits. No possible to proceed
TO changes the global offsets to restore a better zero of collimation
2010-06-26 08:16:11.750359 Changed star and start collimating
Collimated with Z5=-110.35 and Z6=105.68
Closed loop at 2010-06-26 08:24:54.185865
Dump della master:
082814
082851
083104
083245
084008 (possibile offset di tilt nel mezzo dell'acquisizione)
084022
2010-06-26 08:44:21.712800: vento dritto in cupola
strehl > 80% senza S&A
084804
2010-06-26 08:54:43.759769: vento dritto in cupola
085522 (offset di tilt nel mezzo dell'acquisizione)
085554
2010-06-26 08:57:37.422089: aperto il loop per cambiare il ricostruttore
2010-06-26 08:58:40.949775: ripartito il loop
vento a 40deg rispetto alla cupola
091036
091433
091604
2010-06-26 09:01:16.322509 aperto il loop (prima save-skip permanente) (e' possibile che il tracking_num sia sbagliato, piu' vecchio del vero)
2010-06-26 09:25:14.896985: reacquire and recollimating the star
2010-06-26 09:29:28.831955: Collimated with Z5=-45.35 and Z6=15.821
2010-06-26 09:36:29.429599: loop is closed (veli in arrivo)
2010-06-26 09:38:48.849476: qualche colpetto di skip-frame ogni tanto
094018
2010-06-26 09:46:39.550935: da queste parti persa luce per veli
2010-06-26 09:56:54.097309: Fine osservazioni: nuvoloso
--
ArmandoRiccardi - 26 Jun 2010