-- RunaBriguglio - 19 Jun 2010

shell set @02:55

IDLCTRL00 |ALW| 8968|2010-06-19 02:55:15.267826| MAIN > Delta command modal filtering for reducing peak force to 0.15 [N]
IDLCTRL00 |ALW| 8969|2010-06-19 02:55:15.463746| MAIN > Maximum mode index used to apply flat -> # 303
IDLCTRL00 |ALW| 8972|2010-06-19 02:55:15.693041| MAIN > COMM MAX [m] 7.52928e-05
IDLCTRL00 |ALW| 8973|2010-06-19 02:55:15.693206| MAIN > FORCE MAX [N] 0.187772

ventilation doors are closed

shell RIP (internal control), master-dump and saved: meas/adsec_calib/master/MASTERDGN_DATA_20100619_073023.sav

analizing the data, no actuator jump was found

shell rip, data dumped in /meas/adsec_calib/master/MASTERDGN_DATA_20100619_083028.sav

the error was not identified

08:42 shell rip

FASTDGN00 |WAR| 13110558|2010-06-19 08:42:27.946515| FUNCTWARNING > FunctWarning CHCURRAVERAGE-0113 -0.701068
FASTDGN00 |ERR| 13110559|2010-06-19 08:42:27.962074| FUNCTEMERGENCYST > CHCURRAVERAGE-0000 = -0.8 [/home/aoacct/releases/src2/DiagnApp/Funct.h:248]
FASTDGN00 |INF| 13110560|2010-06-19 08:42:27.962125| ADAM > Adam: disabling coils...
FASTDGN00 |ERR| 13110561|2010-06-19 08:42:28.061564| ADAM > Adam: coils disabling failed

dump saved in master/MASTERDGN_DATA_20100619_084228.sav

shell ripped dump saved in meas/adsec_calib/master/MASTERDGN_DATA_20100619_114248.sav

FASTDGN00 |ERR| 13358176|2010-06-19 11:42:48.834819| FUNCTEMERGENCYST > CHCURRAVERAGE-0000 = -0.8 [/home/aoacct/releases/src2/DiagnApp/Funct.h:248]
FASTDGN00 |INF| 13358177|2010-06-19 11:42:48.834872| ADAM > Adam: disabling coils...
FASTDGN00 |ERR| 13358178|2010-06-19 11:42:48.934751| ADAM > Adam: coils disabling failed
All error have been identified: the AdamWatchdog was not disabled, so that the unit unexpectedly was powered off

accelerom data: all data collected here have been taken in Open Loop

Open Loop Closed Loop windSpeed Elevation Note
20100619_031011 20100619_033632 2.5 60  
20100619_033318 20100619_033826      
20100619_034323 20100619_035903      
20100619_034900 20100619_040747      
20100619_041428   2 60  
20100619_041450        
20100619_041545        
20100619_041800   2.4 60  
20100619_042116   1.8 80 Telescope moving
20100619_042229   3.4    
20100619_042430        
20100619_043821   2.5    
20100619_044249   3.8    
  20100619_045218 4.1 74  
  20100619_050219 4.5    
  20100619_051232 3.5    
20100619_052511   2.3 68  
20100619_052626       telescope moving
20100619_052723        
20100619_052907   1.9    
20100619_053125        
  20100619_054300      
  20100619_054711 0.6    
  20100619_055121      
  20100619_055833     picco 50 Hz
  20100619_055901      
20100619_060511        
20100619_060547   2.25 70  
  20100619_061306      
20100619_061306        
20100619_062627        
20100619_063411        
20100619_063701        
20100619_064425        
20100619_064445        
  20100619_064651 1.2 78  
  20100619_070540      
  20100619_072304     waffel noise
20100619_074829        
20100619_075205   0.9 80  
20100619_080512        
20100619_082519   0.6 83  
  20100619_090913 1.6    
  20100619_100011      
  20100619_100028      
  20100619_100038      
         
Topic revision: r4 - 19 Jun 2010, RunaBriguglio
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding Foswiki? Send feedback