-- RunaBriguglio - 26 May 2010

03:17 shell set @47deg elevation

IDLCTRL00 |ALW| 23654|2010-05-26 03:17:05.910289| MAIN > Maximum mode index used to apply flat -> # 586
IDLCTRL00 |ALW| 23658|2010-05-26 03:17:06.101755| MAIN > COMM MAX [m] 7.54265e-05
IDLCTRL00 |ALW| 23658|2010-05-26 03:17:06.101755| MAIN > . FORCE MAX [N] 0.194184

04:30 close loop

FASTDGN00 |WAR| 5204631|2010-05-26 06:45:07.093034| FUNCTWARNING > FunctWarning CHCURRAVERAGE-0466 -0.706591
FASTDGN00 |WAR| 5204632|2010-05-26 06:45:07.104899| FUNCTWARNING > FunctWarning CHCURRAVERAGE-0466 -0.732943
FASTDGN00 |WAR| 5204633|2010-05-26 06:45:07.117086| FUNCTWARNING > FunctWarning CHCURRAVERAGE-0466 -0.743337
FASTDGN00 |WAR| 5204634|2010-05-26 06:45:07.128816| FUNCTWARNING > FunctWarning CHCURRAVERAGE-0466 -0.749213
FASTDGN00 |WAR| 5204635|2010-05-26 06:45:07.144224| FUNCTWARNING > FunctWarning CHCURRAVERAGE-0466 -0.768374
FASTDGN00 |WAR| 5204636|2010-05-26 06:45:07.158631| FUNCTWARNING > FunctWarning CHCURRAVERAGE-0466 -0.733316
FASTDGN00 |WAR| 5204637|2010-05-26 06:45:07.172752| FUNCTWARNING > FunctWarning CHCURRAVERAGE-0466 -0.718773
FASTDGN00 |WAR| 5204638|2010-05-26 06:45:07.184871| FUNCTWARNING > FunctWarning CHCURRAVERAGE-0466 -0.73581
FASTDGN00 |INF| 5204639|2010-05-26 06:45:07.192446| FAST > Processed 72 cycles of 7638 vars in 1 s ( 72 Hz). HW frame rate 1e+03 [DiagnApp.cpp:775]
FASTDGN00 |INF| 5204640|2010-05-26 06:45:07.192477| MAIN > Writing RTDBvars for OFFLOADMODES [FastDiagnostic.cpp:1181]
FASTDGN00 |INF| 5204641|2010-05-26 06:45:07.192606| MAIN > HighOrder offload averaging 4 [FastDiagnostic.cpp:1208]
FASTDGN00 |INF| 5204642|2010-05-26 06:45:07.196666| MAIN > CurrPiston -0.0483228 Ref Force -0.0259198 Ref Force Mean -0.0495757 [FastDiagnostic.cpp:1226]
FASTDGN00 |WAR| 5204643|2010-05-26 06:45:07.200252| FUNCTWARNING > FunctWarning CHCURRAVERAGE-0466 -0.774622
FASTDGN00 |WAR| 5204644|2010-05-26 06:45:07.214377| FUNCTWARNING > FunctWarning CHCURRAVERAGE-0466 -0.788338
FASTDGN00 |ERR| 5204645|2010-05-26 06:45:07.225496| FUNCTEMERGENCYST > CHCURRAVERAGE-0466 = -0.797764 [/home/aoacct/releases/src2/DiagnApp/Funct.h:248]
FASTDGN00 |INF| 5204646|2010-05-26 06:45:07.225545| ADAM > Adam: disabling coils...
FASTDGN00 |INF| 5204647|2010-05-26 06:45:07.226227| ADAM > Adam: coils succesfully disabled
FASTDGN00 |WAR| 5204648|2010-05-26 06:45:07.228319| FUNCTWARNING > FunctWarning CHINTCONTROLCURRENT-0466 -0.524086
FASTDGN00 |ALW| 5204649|2010-05-26 06:45:07.233887| MAIN > dumpadsecdiagnhistory succesfully sent to masterdiagnostic [FastDiagnostic.cpp:1296]

shell set again @74deg elevation

shell ripped, due to wrong manual modes offload to hexapod

IDLCTRL00 |ALW| 25977|2010-05-26 06:49:43.412534| MAIN > Maximum mode index used to apply flat -> # 267
IDLCTRL00 |ALW| 25980|2010-05-26 06:49:43.680940| MAIN > COMM MAX [m] 7.53473e-05
IDLCTRL00 |ALW| 25980|2010-05-26 06:49:43.680940| MAIN > . FORCE MAX [N] 0.184244FASTDGN00 |WAR| 5298416|2010-05-26 07:53:48.634674| FUNCTWARNING > FunctWarning CHINTCONTROLCURRENT-0021 0.392151
FASTDGN00 |WAR| 5298417|2010-05-26 07:53:48.641063| FUNCTWARNING > FunctWarning CHINTCONTROLCURRENT-0021 0.420594
FASTDGN00 |WAR| 5298418|2010-05-26 07:53:48.649618| FUNCTWARNING > FunctWarning CHINTCONTROLCURRENT-0021 0.443473
FASTDGN00 |WAR| 5298419|2010-05-26 07:53:48.657035| FUNCTWARNING > FunctWarning CHCURRAVERAGE-0335 -0.713589
FASTDGN00 |WAR| 5298420|2010-05-26 07:53:48.666694| FUNCTWARNING > FunctWarning CHCURRAVERAGE-0335 -0.749372
FASTDGN00 |ERR| 5298421|2010-05-26 07:53:48.676796| FUNCTEMERGENCYST > CHCURRAVERAGE-0028 = 0.8 [/home/aoacct/releases/src2/DiagnApp/Funct.h:248]
FASTDGN00 |INF| 5298422|2010-05-26 07:53:48.711394| ADAM > Adam: disabling coils...
FASTDGN00 |INF| 5298423|2010-05-26 07:53:48.713828| ADAM > Adam: coils succesfully disabled
FASTDGN00 |WAR| 5298424|2010-05-26 07:53:48.720267| FUNCTWARNING > FunctWarning CHCURRAVERAGE-0335 -0.717272
FASTDGN00 |ERR| 5298425|2010-05-26 07:53:48.722857| FUNCTALARM > FunctAlarm CHINTCONTROLCURRENT-0046 0.768268
FASTDGN00 |ALW| 5298426|2010-05-26 07:53:48.728002| MAIN > dumpadsecdiagnhistory succesfully sent to masterdiagnostic [FastDiagnostic.cpp:1296]
FASTDGN00 |WAR| 5298427|2010-05-26 07:53:48.735395| FUNCTWARNING > FunctWarning CHCURRAVERAGE-0021 0.758267


set again @72deg elevation

then ripped again

FASTDGN00 |WAR| 5312480|2010-05-26 07:57:56.832647| FUNCTWARNING > FunctWarning CHINTCONTROLCURRENT-0051 -0.309611
FASTDGN00 |WAR| 5312481|2010-05-26 07:57:56.841481| FUNCTWARNING > FunctWarning CHINTCONTROLCURRENT-0051 -0.324651
FASTDGN00 |WAR| 5312482|2010-05-26 07:57:56.856601| FUNCTWARNING > FunctWarning CHINTCONTROLCURRENT-0051 -0.388289
FASTDGN00 |WAR| 5312483|2010-05-26 07:57:56.866362| FUNCTWARNING > FunctWarning CHINTCONTROLCURRENT-0051 -0.399719
FASTDGN00 |ERR| 5312484|2010-05-26 07:57:56.878847| FUNCTEMERGENCYST > CHCURRAVERAGE-0174 = 0.8 [/home/aoacct/releases/src2/DiagnApp/Funct.h:248]
FASTDGN00 |INF| 5312485|2010-05-26 07:57:56.878879| ADAM > Adam: disabling coils...
FASTDGN00 |INF| 5312486|2010-05-26 07:57:56.879582| ADAM > Adam: coils succesfully disabled
FASTDGN00 |WAR| 5312487|2010-05-26 07:57:56.881165| FUNCTWARNING > FunctWarning CHINTCONTROLCURRENT-0051 -0.407988
FASTDGN00 |ERR| 5312488|2010-05-26 07:57:56.881282| FUNCTALARM > FunctAlarm CHINTCONTROLCURRENT-0174 0.729579
FASTDGN00 |ALW| 5312489|2010-05-26 07:57:56.885245| MAIN > dumpadsecdiagnhistory succesfully sent to masterdiagnostic [FastDiagnostic.cpp:1296]
FASTDGN00 |WAR| 5312490|2010-05-26 07:57:56.887406| FUNCTWARNING > FunctWarning CHCURRAVERAGE-0012 -0.704386
FASTDGN00 |ERR| 5312491|2010-05-26 07:57:56.887457| FUNCTEMERGENCYST > CHCURRAVERAGE-0095 = -0.799863 [/home/aoacct/releases/src2/DiagnApp/Funct.h:248]

09:30 guider not stopped, hence mirror is ripped due to accumulation of tilt

-- RunaBriguglio - 26 May 2010

03:17 shell set @47deg elevation

IDLCTRL00 |ALW| 23654|2010-05-26 03:17:05.910289| MAIN > Maximum mode index used to apply flat -> # 586
IDLCTRL00 |ALW| 23658|2010-05-26 03:17:06.101755| MAIN > COMM MAX [m] 7.54265e-05
IDLCTRL00 |ALW| 23658|2010-05-26 03:17:06.101755| MAIN > . FORCE MAX [N] 0.194184

04:30 close loop

FASTDGN00 |WAR| 5204631|2010-05-26 06:45:07.093034| FUNCTWARNING > FunctWarning CHCURRAVERAGE-0466 -0.706591
FASTDGN00 |WAR| 5204632|2010-05-26 06:45:07.104899| FUNCTWARNING > FunctWarning CHCURRAVERAGE-0466 -0.732943
FASTDGN00 |WAR| 5204633|2010-05-26 06:45:07.117086| FUNCTWARNING > FunctWarning CHCURRAVERAGE-0466 -0.743337
FASTDGN00 |WAR| 5204634|2010-05-26 06:45:07.128816| FUNCTWARNING > FunctWarning CHCURRAVERAGE-0466 -0.749213
FASTDGN00 |WAR| 5204635|2010-05-26 06:45:07.144224| FUNCTWARNING > FunctWarning CHCURRAVERAGE-0466 -0.768374
FASTDGN00 |WAR| 5204636|2010-05-26 06:45:07.158631| FUNCTWARNING > FunctWarning CHCURRAVERAGE-0466 -0.733316
FASTDGN00 |WAR| 5204637|2010-05-26 06:45:07.172752| FUNCTWARNING > FunctWarning CHCURRAVERAGE-0466 -0.718773
FASTDGN00 |WAR| 5204638|2010-05-26 06:45:07.184871| FUNCTWARNING > FunctWarning CHCURRAVERAGE-0466 -0.73581
FASTDGN00 |INF| 5204639|2010-05-26 06:45:07.192446| FAST > Processed 72 cycles of 7638 vars in 1 s ( 72 Hz). HW frame rate 1e+03 [DiagnApp.cpp:775]
FASTDGN00 |INF| 5204640|2010-05-26 06:45:07.192477| MAIN > Writing RTDBvars for OFFLOADMODES [FastDiagnostic.cpp:1181]
FASTDGN00 |INF| 5204641|2010-05-26 06:45:07.192606| MAIN > HighOrder offload averaging 4 [FastDiagnostic.cpp:1208]
FASTDGN00 |INF| 5204642|2010-05-26 06:45:07.196666| MAIN > CurrPiston -0.0483228 Ref Force -0.0259198 Ref Force Mean -0.0495757 [FastDiagnostic.cpp:1226]
FASTDGN00 |WAR| 5204643|2010-05-26 06:45:07.200252| FUNCTWARNING > FunctWarning CHCURRAVERAGE-0466 -0.774622
FASTDGN00 |WAR| 5204644|2010-05-26 06:45:07.214377| FUNCTWARNING > FunctWarning CHCURRAVERAGE-0466 -0.788338
FASTDGN00 |ERR| 5204645|2010-05-26 06:45:07.225496| FUNCTEMERGENCYST > CHCURRAVERAGE-0466 = -0.797764 [/home/aoacct/releases/src2/DiagnApp/Funct.h:248]
FASTDGN00 |INF| 5204646|2010-05-26 06:45:07.225545| ADAM > Adam: disabling coils...
FASTDGN00 |INF| 5204647|2010-05-26 06:45:07.226227| ADAM > Adam: coils succesfully disabled
FASTDGN00 |WAR| 5204648|2010-05-26 06:45:07.228319| FUNCTWARNING > FunctWarning CHINTCONTROLCURRENT-0466 -0.524086
FASTDGN00 |ALW| 5204649|2010-05-26 06:45:07.233887| MAIN > dumpadsecdiagnhistory succesfully sent to masterdiagnostic [FastDiagnostic.cpp:1296]

shell set again @74deg elevation

shell ripped, due to wrong manual modes offload to hexapod

IDLCTRL00 |ALW| 25977|2010-05-26 06:49:43.412534| MAIN > Maximum mode index used to apply flat -> # 267
IDLCTRL00 |ALW| 25980|2010-05-26 06:49:43.680940| MAIN > COMM MAX [m] 7.53473e-05
IDLCTRL00 |ALW| 25980|2010-05-26 06:49:43.680940| MAIN > . FORCE MAX [N] 0.184244FASTDGN00 |WAR| 5298416|2010-05-26 07:53:48.634674| FUNCTWARNING > FunctWarning CHINTCONTROLCURRENT-0021 0.392151
FASTDGN00 |WAR| 5298417|2010-05-26 07:53:48.641063| FUNCTWARNING > FunctWarning CHINTCONTROLCURRENT-0021 0.420594
FASTDGN00 |WAR| 5298418|2010-05-26 07:53:48.649618| FUNCTWARNING > FunctWarning CHINTCONTROLCURRENT-0021 0.443473
FASTDGN00 |WAR| 5298419|2010-05-26 07:53:48.657035| FUNCTWARNING > FunctWarning CHCURRAVERAGE-0335 -0.713589
FASTDGN00 |WAR| 5298420|2010-05-26 07:53:48.666694| FUNCTWARNING > FunctWarning CHCURRAVERAGE-0335 -0.749372
FASTDGN00 |ERR| 5298421|2010-05-26 07:53:48.676796| FUNCTEMERGENCYST > CHCURRAVERAGE-0028 = 0.8 [/home/aoacct/releases/src2/DiagnApp/Funct.h:248]
FASTDGN00 |INF| 5298422|2010-05-26 07:53:48.711394| ADAM > Adam: disabling coils...
FASTDGN00 |INF| 5298423|2010-05-26 07:53:48.713828| ADAM > Adam: coils succesfully disabled
FASTDGN00 |WAR| 5298424|2010-05-26 07:53:48.720267| FUNCTWARNING > FunctWarning CHCURRAVERAGE-0335 -0.717272
FASTDGN00 |ERR| 5298425|2010-05-26 07:53:48.722857| FUNCTALARM > FunctAlarm CHINTCONTROLCURRENT-0046 0.768268
FASTDGN00 |ALW| 5298426|2010-05-26 07:53:48.728002| MAIN > dumpadsecdiagnhistory succesfully sent to masterdiagnostic [FastDiagnostic.cpp:1296]
FASTDGN00 |WAR| 5298427|2010-05-26 07:53:48.735395| FUNCTWARNING > FunctWarning CHCURRAVERAGE-0021 0.758267


set again @72deg elevation

then ripped again

FASTDGN00 |WAR| 5312480|2010-05-26 07:57:56.832647| FUNCTWARNING > FunctWarning CHINTCONTROLCURRENT-0051 -0.309611
FASTDGN00 |WAR| 5312481|2010-05-26 07:57:56.841481| FUNCTWARNING > FunctWarning CHINTCONTROLCURRENT-0051 -0.324651
FASTDGN00 |WAR| 5312482|2010-05-26 07:57:56.856601| FUNCTWARNING > FunctWarning CHINTCONTROLCURRENT-0051 -0.388289
FASTDGN00 |WAR| 5312483|2010-05-26 07:57:56.866362| FUNCTWARNING > FunctWarning CHINTCONTROLCURRENT-0051 -0.399719
FASTDGN00 |ERR| 5312484|2010-05-26 07:57:56.878847| FUNCTEMERGENCYST > CHCURRAVERAGE-0174 = 0.8 [/home/aoacct/releases/src2/DiagnApp/Funct.h:248]
FASTDGN00 |INF| 5312485|2010-05-26 07:57:56.878879| ADAM > Adam: disabling coils...
FASTDGN00 |INF| 5312486|2010-05-26 07:57:56.879582| ADAM > Adam: coils succesfully disabled
FASTDGN00 |WAR| 5312487|2010-05-26 07:57:56.881165| FUNCTWARNING > FunctWarning CHINTCONTROLCURRENT-0051 -0.407988
FASTDGN00 |ERR| 5312488|2010-05-26 07:57:56.881282| FUNCTALARM > FunctAlarm CHINTCONTROLCURRENT-0174 0.729579
FASTDGN00 |ALW| 5312489|2010-05-26 07:57:56.885245| MAIN > dumpadsecdiagnhistory succesfully sent to masterdiagnostic [FastDiagnostic.cpp:1296]
FASTDGN00 |WAR| 5312490|2010-05-26 07:57:56.887406| FUNCTWARNING > FunctWarning CHCURRAVERAGE-0012 -0.704386
FASTDGN00 |ERR| 5312491|2010-05-26 07:57:56.887457| FUNCTEMERGENCYST > CHCURRAVERAGE-0095 = -0.799863 [/home/aoacct/releases/src2/DiagnApp/Funct.h:248]

09:30 guider not stopped, hence mirror is ripped due to accumulation of tilt

shell ripped, then problems with communication with ADAM (the unit is On). then AOS is found died

IDLCTRL00 |ALW| 32601|2010-05-26 10:32:51.987517| MAIN > EndCmd
IDLCTRL00 |ALW| 32602|2010-05-26 10:32:51.987557| MAIN > % Unable to apply format code Z to input: ">0".
IDLCTRL00 |ALW| 32602|2010-05-26 10:32:51.987557| MAIN > . % Execution halted at: ADAM_UPDATE 41
IDLCTRL00 |ALW| 32602|2010-05-26 10:32:51.987557| MAIN > . /home/aoacct/AO/current/idl/adsec_lib/adsec/level3/init_adam.pro
IDLCTRL00 |ALW| 32602|2010-05-26 10:32:51.987557| MAIN > . % FSM_SET_FLAT 185
IDLCTRL00 |ALW| 32602|2010-05-26 10:32:51.987557| MAIN > . /home/aoacct/AO/current/idl/adsec_lib/adsec_scripts/fsm_set_flat.pro
IDLCTRL00 |ALW| 32602|2010-05-26 10:32:51.987557| MAIN > . % ADAM_UPDATE 41
IDLCTRL00 |ALW| 32602|2010-05-26 10:32:51.987557| MAIN > . /home/aoacct/AO/current/idl/adsec_lib/adsec/level3/init_adam.pro
IDLCTRL00 |ALW| 32602|2010-05-26 10:32:51.987557| MAIN > . % ADAM_SYS_RESET 181
IDLCTRL00 |ALW| 32602|2010-05-26 10:32:51.987557| MAIN > . /home/aoacct/AO/current/idl/adsec_lib/adsec/level3/init_adam.pro
IDLCTRL00 |ALW| 32602|2010-05-26 10:32:51.987557| MAIN > . % FSM_RESET 12
IDLCTRL00 |ALW| 32602|2010-05-26 10:32:51.987557| MAIN > . /home/aoacct/AO/current/idl/adsec_lib/adsec_scripts/fsm_reset.pro
IDLCTRL00 |ALW| 32602|2010-05-26 10:32:51.987557| MAIN > . % FSM_LOAD_PROGRAM 77
IDLCTRL00 |ALW| 32602|2010-05-26 10:32:51.987557| MAIN > . /home/aoacct/AO/current/idl/adsec_lib/adsec_scripts/fsm_load_program.pro
IDLCTRL00 |ALW| 32602|2010-05-26 10:32:51.987557| MAIN > . % ADAM_UPDATE 41
IDLCTRL00 |ALW| 32602|2010-05-26 10:32:51.987557| MAIN > . /home/aoacct/AO/current/idl/adsec_lib/adsec/level3/init_adam.pro
IDLCTRL00 |ALW| 32602|2010-05-26 10:32:51.987557| MAIN > . % FSM_SET_FLAT 185
IDLCTRL00 |ALW| 32602|2010-05-26 10:32:51.987557| MAIN > . /home/aoacct/AO/current/idl/adsec_lib/adsec_scripts/fsm_set_flat.pro
IDLCTRL00 |ALW| 32602|2010-05-26 10:32:51.987557| MAIN > . % $MAIN$
IDLCTRL00 |ALW| 32602|2010-05-26 10:32:51.987557| MAIN > .
IDLCTRL00 |ALW| 32603|2010-05-26 10:34:20.713982| MAIN > StartCmd

problem solved stopping and starting up again the processes

shell set @43 deg elevation

IDLCTRL00 |ALW| 1196|2010-05-26 10:44:47.303739| MAIN > Maximum mode index used to apply flat -> # 95
IDLCTRL00 |ALW| 1199|2010-05-26 10:44:47.535640| MAIN > COMM MAX [m] 7.53568e-05
IDLCTRL00 |ALW| 1201|2010-05-26 10:44:47.536297| MAIN > FORCE MAX [N] 0.205634

end of activities 12:00 approx. shell ripped to let telescope go down to horizon

shell set to acquire noise measurements. 90 deg elevation

IDLCTRL00 |ALW| 2417|2010-05-26 12:25:41.366437| MAIN > Maximum mode index used to apply flat -> # 641
IDLCTRL00 |ALW| 2419|2010-05-26 12:25:41.492457| MAIN > COMM MAX [m] 7.53747e-05
IDLCTRL00 |ALW| 2419|2010-05-26 12:25:41.492457| MAIN > . FORCE MAX [N] 0.173098