Tests show that the RIP just after setting and flattening happen because the HO-offload is enabled and applyed too short time after the enabling.

The execution of the HO-offload has been temporarily removed for debugging (only the astigmatism-vs-elevation is applied)

================================

a sequence of dump files is generated, not produced by any RIP. See the following section of IDLctrl log:

IDLCTRL00 |ALW| 25288|2010-04-03 23:51:33.656542| MAIN > StartCmd
IDLCTRL00 |ALW| 25289|2010-04-03 23:51:33.656653| MAIN > Get info from HOUSEKPR00 variables...
IDLCTRL00 |ALW| 25290|2010-04-03 23:51:34.427840| MAIN > Get info from MASTDIAGN00 dump file: ADAPTIVE-SECONDARY_00001270338693_20100403_235133.log
IDLCTRL00 |ALW| 25291|2010-04-03 23:51:34.735655| MAIN > Dump loaded.
IDLCTRL00 |ALW| 25292|2010-04-03 23:51:34.735738| MAIN > Waiting for diagnostic updates..
IDLCTRL00 |ALW| 25293|2010-04-03 23:51:36.658295| MAIN > Get info from HOUSEKPR00 variables...
IDLCTRL00 |ALW| 25294|2010-04-03 23:51:37.639802| MAIN > Done
IDLCTRL00 |ALW| 25295|2010-04-03 23:51:37.640014| MAIN > Get info from ADAMHOUSEKPR00 variables...
IDLCTRL00 |ALW| 25296|2010-04-03 23:51:37.641076| MAIN > Done
IDLCTRL00 |ALW| 25297|2010-04-03 23:51:37.933170| MAIN > Adam watchdog not expired.
IDLCTRL00 |ALW| 25297|2010-04-03 23:51:37.933170| MAIN > . DSP board watchdog not expired.
IDLCTRL00 |ALW| 25297|2010-04-03 23:51:37.933170| MAIN > . Distance theshold check passed with no issues found.
IDLCTRL00 |ALW| 25297|2010-04-03 23:51:37.933170| MAIN > . Temperature check passed with no issues found.
IDLCTRL00 |ALW| 25298|2010-04-03 23:51:37.945088| MAIN > EndCmd
IDLCTRL00 |ALW| 25299|2010-04-03 23:51:37.945517| MAIN > StartCmd
IDLCTRL00 |ALW| 25300|2010-04-03 23:51:37.945554| MAIN > 0
IDLCTRL00 |ALW| 25301|2010-04-03 23:51:37.945579| MAIN > EndCmd
IDLCTRL00 |ALW| 25302|2010-04-03 23:51:37.946362| MAIN > StartCmd
IDLCTRL00 |ALW| 25303|2010-04-03 23:51:37.946398| MAIN >
IDLCTRL00 |ALW| 25304|2010-04-03 23:51:37.946492| MAIN > Get info from HOUSEKPR00 variables...
IDLCTRL00 |ALW| 25305|2010-04-03 23:51:38.726342| MAIN > Get info from MASTDIAGN00 dump file: ADAPTIVE-SECONDARY_00001270338693_20100403_235133.log
IDLCTRL00 |ALW| 25306|2010-04-03 23:51:39.051915| MAIN > Dump loaded.
IDLCTRL00 |ALW| 25307|2010-04-03 23:51:39.051983| MAIN > Waiting for diagnostic updates..
IDLCTRL00 |ALW| 25308|2010-04-03 23:51:40.947465| MAIN > Get info from HOUSEKPR00 variables...
IDLCTRL00 |ALW| 25309|2010-04-03 23:51:41.723082| MAIN > Done
IDLCTRL00 |ALW| 25310|2010-04-03 23:51:41.723238| MAIN > Get info from ADAMHOUSEKPR00 variables...
IDLCTRL00 |ALW| 25311|2010-04-03 23:51:41.724452| MAIN > Done
IDLCTRL00 |ALW| 25312|2010-04-03 23:51:42.018346| MAIN > Adam watchdog not expired.
IDLCTRL00 |ALW| 25312|2010-04-03 23:51:42.018346| MAIN > . DSP board watchdog not expired.
IDLCTRL00 |ALW| 25312|2010-04-03 23:51:42.018346| MAIN > . Distance theshold check passed with no issues found.
IDLCTRL00 |ALW| 25312|2010-04-03 23:51:42.018346| MAIN > . Temperature check passed with no issues found.
IDLCTRL00 |ALW| 25313|2010-04-03 23:51:42.028957| MAIN > EndCmd
IDLCTRL00 |ALW| 25314|2010-04-03 23:51:42.029290| MAIN > StartCmd
IDLCTRL00 |ALW| 25315|2010-04-03 23:51:42.029322| MAIN > 0
IDLCTRL00 |ALW| 25315|2010-04-03 23:51:42.029322| MAIN > . EndCmd
IDLCTRL00 |ALW| 25316|2010-04-03 23:51:42.590582| MAIN > StartCmd
IDLCTRL00 |ALW| 25317|2010-04-03 23:51:42.590714| MAIN > /tmp/highorderoffloadvector.fits
IDLCTRL00 |ALW| 25318|2010-04-03 23:51:42.757874| MAIN > Param Selector: 000041C0
IDLCTRL00 |ALW| 25319|2010-04-03 23:51:42.757933| MAIN > % READFITS: Now reading 672 element array
IDLCTRL00 |ALW| 25319|2010-04-03 23:51:42.757933| MAIN > .
IDLCTRL00 |ALW| 25320|2010-04-03 23:51:42.784097| MAIN > COMM MAX [m] 7.75720e-05
IDLCTRL00 |ALW| 25321|2010-04-03 23:51:42.784171| MAIN > FORCE MAX [N] 0.244558
IDLCTRL00 |ALW| 25322|2010-04-03 23:51:43.071474| MAIN > Param Selector: 000061C0
IDLCTRL00 |ALW| 25323|2010-04-03 23:51:43.098487| MAIN > Applying LUT correction for low order Zernike
IDLCTRL00 |ALW| 25324|2010-04-03 23:51:43.098720| MAIN > elevation is 89.962348
IDLCTRL00 |ALW| 25325|2010-04-03 23:51:43.098858| MAIN > z6 is 0.00000
IDLCTRL00 |ALW| 25326|2010-04-03 23:51:43.323417| MAIN > Param Selector: 000061C0
IDLCTRL00 |ALW| 25327|2010-04-03 23:51:43.567504| MAIN > Param Selector: 000061C0
IDLCTRL00 |ALW| 25328|2010-04-03 23:51:43.594344| MAIN > COMM MAX [m] 7.75720e-05
IDLCTRL00 |ALW| 25329|2010-04-03 23:51:43.594387| MAIN > FORCE MAX [N] 0.246736
IDLCTRL00 |ALW| 25330|2010-04-03 23:51:43.901290| MAIN > Param Selector: 000041C0
IDLCTRL00 |ALW| 25331|2010-04-03 23:51:44.133779| MAIN > Param Selector: 000041C0
IDLCTRL00 |ALW| 25332|2010-04-03 23:51:44.154916| MAIN > Done.
IDLCTRL00 |ALW| 25333|2010-04-03 23:51:44.154973| MAIN > EndCmd

======================================================================

Preliminary Operations

The dome is open at approx 2:00UT

shell set at 02:19UT but fails

FASTDGN00 |ERR| 2966925|2010-04-04 02:19:09.529061| FUNCTEMERGENCYST > CHCURRAVERAGE-0116 = -0.8 [/home/aoacct/releases/src2/DiagnApp/Funct.h:248]
FASTDGN00 |INF| 2966926|2010-04-04 02:19:09.529111| ADAM > Adam: disabling coils...

ADSECARBITRATOR is died on 02:19:11

AOS killed then restarted

recover failure

strong wind also in the dome (6m/s)

mirror set 02:28:35 but fails

FASTDGN00 |ERR| 3014241|2010-04-04 02:29:28.658159| FUNCTEMERGENCYST > CHCURRAVERAGE-0159 = -0.792723

recover failure (2x, as the first time finished but the fsm status was still failure)

02:35:14 shell set successfully

Maximum mode index used to apply flat -> # 396
COMM MAX [m] 7.75813e-05
FORCE MAX [N] 0.285561

02:49:19.5 get_zern_flat_lut modified to implement new LUT. .compile

IDLCTRL00 |ALW| 34066|2010-04-04 02:49:01.680707| MAIN > elevation is 24.150849
IDLCTRL00 |ALW| 34067|2010-04-04 02:49:01.680862| MAIN > z6 is 2.36790e-06
IDLCTRL00 |ALW| 34070|2010-04-04 02:49:02.165312| MAIN > COMM MAX [m] 7.73677e-05
IDLCTRL00 |ALW| 34071|2010-04-04 02:49:02.165403| MAIN > FORCE MAX [N] 0.406203
IDLCTRL00 |ALW| 34081|2010-04-04 02:49:19.510606| MAIN > % Compiled module: GET_ZERN_FLAT_LUT.

IDLCTRL00 |ALW| 34085|2010-04-04 02:49:21.934880| MAIN > elevation is 24.218412
IDLCTRL00 |ALW| 34086|2010-04-04 02:49:21.934990| MAIN > z6 is 4.65784e-06
IDLCTRL00 |ALW| 34089|2010-04-04 02:49:22.424546| MAIN > COMM MAX [m] 8.05239e-05
IDLCTRL00 |ALW| 34090|2010-04-04 02:49:22.424642| MAIN > FORCE MAX [N] 0.468113

!!!!

the log from 02:49 to end of operations (approx 11:30) was lost due to possible error in saving the page.

below is attached the FASTDGN output for the occurred faults

FASTDGN00 |ERR| 3138487|2010-04-04 04:25:09.939936| FUNCTEMERGENCYST > CHCURRAVERAGE-0530 = -0.799965
FASTDGN00 |ERR| 3145724|2010-04-04 04:27:49.674588| FUNCTEMERGENCYST > CHCURRAVERAGE-0116 = 0.8
FASTDGN00 |ERR| 3183039|2010-04-04 04:34:26.009234| FUNCTEMERGENCYST > CHCURRAVERAGE-0159 = -0.79223
FASTDGN00 |ERR| 3186163|2010-04-04 04:34:40.360151| FUNCTEMERGENCYST > CHCURRAVERAGE-0352 = -0.8
FASTDGN00 |ERR| 3214448|2010-04-04 04:48:09.896965| FUNCTEMERGENCYST > CHCURRAVERAGE-0129 = -0.791146
FASTDGN00 |ERR| 3237014|2010-04-04 05:01:24.110069| FUNCTEMERGENCYST > CHCURRAVERAGE-0129 = -0.799374
FASTDGN00 |ERR| 3252179|2010-04-04 05:07:35.096851| FUNCTEMERGENCYST > CHCURRAVERAGE-0596 = -0.8
FASTDGN00 |ERR| 3273650|2010-04-04 05:16:53.431689| FUNCTEMERGENCYST > CHCURRAVERAGE-0129 = -0.799649
FASTDGN00 |ERR| 222246|2010-04-04 10:08:08.618031| FUNCTEMERGENCYST > CHCURRAVERAGE-0159 = -0.799937
FASTDGN00 |ERR| 242345|2010-04-04 10:14:23.556029| FUNCTEMERGENCYST > CHCURRAVERAGE-0159 = -0.79923
FASTDGN00 |ERR| 249186|2010-04-04 10:18:39.514526| FUNCTEMERGENCYST > CHCURRAVERAGE-0159 = -0.79018

attached below the actuators map.

-- ArmandoRiccardi - 04 Apr 2010
Topic revision: r3 - 04 Apr 2010, RunaBriguglio
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding Foswiki? Send feedback