Time is UTC
R.AOSR00.AMB.WINDSPEED has been set to 10.0 for enabling TSS
=====================
DX and SX shutters open
Lateral and back vent closed
External wind: about from 220deg, 10m/s (hand probe on the top of the dome)
reading inside the dome: 1.8m/s (1m ave), gust: 3.3 (1s ave)
=====================
R.AOSR00.TEL.EL = 65.0
Creating the above variable did not work. Setting overcurrent threshold by IDL
04:18:36.343615:
print, setpistoncurrent(65.0)
Setting overcurrent protection for 65.00 [deg]
Push total overcurrent threshold set to 48.45
45
524288
2949123
Done.
=====================
El: 67deg, Az: 41deg (tracking object)
=====================
setting the shell
IDLCTRL00 |ALW| 1543|2010-03-14 04:33:00.732818| MAIN > Delta command modal filtering for reducing peak force to 0.25 [N]
IDLCTRL00 |ALW| 1544|2010-03-14 04:33:00.911352| MAIN > Maximum mode index used to apply flat -> # 303
IDLCTRL00 |ALW| 1545|2010-03-14 04:33:00.913995| MAIN > passo 3
IDLCTRL00 |ALW| 1546|2010-03-14 04:33:01.101814| MAIN > Param Selector: 000041C0
IDLCTRL00 |ALW| 1547|2010-03-14 04:33:01.122257| MAIN > COMM MAX [m] 7.55271e-05
IDLCTRL00 |ALW| 1548|2010-03-14 04:33:01.122533| MAIN > FORCE MAX [N] 0.245118
=======================
Dome moved just before 04:46:22.449295
El: 56deg, Az: 159
wind in dome: about 2m (1m ave)
========================
Dome moved just before: 05:03:12.006716
El: 78 deg, Az: 21 deg
print, setpistoncurrent(75.0)
Setting overcurrent protection for 75.00 [deg]
Push total overcurrent threshold set to 45.18
44
524288
2883587
wind in Dome: 0.6m/s (1m ave) 2m/s max gust (1s ave)
=========================
Dome moved about at 05:15:48.60683
El: 57 deg, Az: 120 deg
print, setpistoncurrent(75.0)
Setting overcurrent protection for 50.00 [deg]
Push total overcurrent threshold set to 52.86
46
524288
3014659
Done.
wind in Dome: 2m/s (1m ave) 7m/s max gust (1s ave)
the wind speed went down with time. At 05:45:26.80708 1.3m/s (1m ave) gust 2m/s (1s ave)
Dew point approching the external temperature
Moving telescope to horizon: MIRROR RESET AT HORIZON POINTING (el. 10deg for sure was functioning)
Closing shutters at 05:51:36.82491
End of observations
The shell had no problems till about 10 degrees. After that the shell ripped.
Diagnostic data saved to : $ADOPT_LOG/ASM_FAULT_DUMP_00001268535878_20100314_030438.sav
Fastdiagnostic dump :NOT DONE: behavior: quando la int_ctrl_current sale piano piano sembra che il dump non vada
maybe ADAPTIVE-SECONDARY_00001268546256_20100314_055736.log
Actuators not properly working:
FASTDGN00 |WAR| 318385|2010-03-14 05:49:43.655762| FUNCTWARNING >
FunctWarning CHDISTRMS-0277 3.30438e-08
FASTDGN00 |WAR| 318386|2010-03-14 05:49:43.666588| FUNCTWARNING >
FunctWarning CHDISTRMS-0277 5.66543e-08
FASTDGN00 |WAR| 318387|2010-03-14 05:49:43.677204| FUNCTWARNING >
FunctWarning CHDISTRMS-0277 4.4638e-08
FASTDGN00 |WAR| 318388|2010-03-14 05:49:43.687934| FUNCTWARNING >
FunctWarning CHDISTRMS-0277 4.17694e-08
FASTDGN00 |WAR| 318389|2010-03-14 05:49:43.698577| FUNCTWARNING >
FunctWarning CHDISTRMS-0277 5.11885e-08
FASTDGN00 |WAR| 318390|2010-03-14 05:49:43.709133| FUNCTWARNING >
FunctWarning CHDISTRMS-0277 4.69992e-08
Actuator not properly working or HIGH order mode: FASTDGN00 |WAR| 318424|2010-03-14 05:49:43.854340| FUNCTWARNING >
FunctWarning CHINTCONTROLCURRENT-0500 -0.312287
FASTDGN00 |WAR| 318425|2010-03-14 05:49:43.865219| FUNCTWARNING >
FunctWarning CHINTCONTROLCURRENT-0500 -0.31411
FASTDGN00 |WAR| 318426|2010-03-14 05:49:43.876302| FUNCTWARNING >
FunctWarning CHINTCONTROLCURRENT-0500 -0.31627
FASTDGN00 |WAR| 318427|2010-03-14 05:49:43.886423| FUNCTWARNING >
FunctWarning CHINTCONTROLCURRENT-0500 -0.317359
FASTDGN00 |WAR| 318428|2010-03-14 05:49:43.896847| FUNCTWARNING >
FunctWarning CHINTCONTROLCURRENT-0500 -0.319603
FASTDGN00 |WAR| 318429|2010-03-14 05:49:43.906859| FUNCTWARNING >
FunctWarning CHINTCONTROLCURRENT-0500 -0.321472
FASTDGN00 |WAR| 318430|2010-03-14 05:49:43.917259| FUNCTWARNING >
FunctWarning CHINTCONTROLCURRENT-0500 -0.324212
FASTDGN00 |WAR| 318431|2010-03-14 05:49:43.927298| FUNCTWARNING >
FunctWarning CHINTCONTROLCURRENT-0500 -0.327375
FASTDGN00 |WAR| 318432|2010-03-14 05:49:43.937318| FUNCTWARNING >
FunctWarning CHINTCONTROLCURRENT-0500 -0.330878
FASTDGN00 |WAR| 318433|2010-03-14 05:49:43.947301| FUNCTWARNING >
FunctWarning CHINTCONTROLCURRENT-0500 -0.334979
FASTDGN00 |WAR| 318434|2010-03-14 05:49:43.958309| FUNCTWARNING >
FunctWarning CHINTCONTROLCURRENT-0500 -0.340067
FASTDGN00 |WAR| 318435|2010-03-14 05:49:43.969429| FUNCTWARNING >
FunctWarning CHINTCONTROLCURRENT-0500 -0.345769
FASTDGN00 |WAR| 318436|2010-03-14 05:49:43.980130| FUNCTWARNING >
FunctWarning CHINTCONTROLCURRENT-0500 -0.353474
FASTDGN00 |WAR| 318437|2010-03-14 05:49:43.991445| FUNCTWARNING >
FunctWarning CHINTCONTROLCURRENT-0500 -0.360891
FASTDGN00 |WAR| 318438|2010-03-14 05:49:44.003129| FUNCTWARNING >
FunctWarning CHINTCONTROLCURRENT-0500 -0.369524
FASTDGN00 |WAR| 318439|2010-03-14 05:49:44.013703| FUNCTWARNING >
FunctWarning CHINTCONTROLCURRENT-0500 -0.377868
FASTDGN00 |WAR| 318440|2010-03-14 05:49:44.024373| FUNCTWARNING >
FunctWarning CHINTCONTROLCURRENT-0500 -0.386936
FASTDGN00 |WAR| 318441|2010-03-14 05:49:44.035022| FUNCTWARNING >
FunctWarning CHINTCONTROLCURRENT-0500 -0.398719
FASTDGN00 |WAR| 318442|2010-03-14 05:49:44.045646| FUNCTWARNING >
FunctWarning CHINTCONTROLCURRENT-0500 -0.409863
FASTDGN00 |WAR| 318443|2010-03-14 05:49:44.066301| FUNCTWARNING >
FunctWarning CHINTCONTROLCURRENT-0500 -0.425332
FASTDGN00 |WAR| 318444|2010-03-14 05:49:44.081514| FUNCTWARNING >
FunctWarning CHINTCONTROLCURRENT-0500 -0.463138
FASTDGN00 |WAR| 318445|2010-03-14 05:49:44.092042| FUNCTWARNING >
FunctWarning CHINTCONTROLCURRENT-0478 -0.303721
FASTDGN00 |WAR| 318446|2010-03-14 05:49:44.102567| FUNCTWARNING >
FunctWarning CHINTCONTROLCURRENT-0478 -0.319373
FASTDGN00 |INF| 318447|2010-03-14 05:49:44.107864| FAST > Processed 124 cycles of 7654 vars in 1.23 s ( 100 Hz). HW frame rate 498 [DiagnApp.cpp:775]
FASTDGN00 |WAR| 318448|2010-03-14 05:49:44.113350| FUNCTWARNING >
FunctWarning CHINTCONTROLCURRENT-0478 -0.336775
FASTDGN00 |WAR| 318449|2010-03-14 05:49:44.123911| FUNCTWARNING >
FunctWarning CHINTCONTROLCURRENT-0478 -0.359579
FASTDGN00 |WAR| 318450|2010-03-14 05:49:44.134421| FUNCTWARNING >
FunctWarning CHINTCONTROLCURRENT-0478 -0.380225
FASTDGN00 |WAR| 318451|2010-03-14 05:49:44.144998| FUNCTWARNING >
FunctWarning CHINTCONTROLCURRENT-0478 -0.403159
FASTDGN00 |WAR| 318452|2010-03-14 05:49:44.153768| FUNCTWARNING >
FunctWarning CHCURRAVERAGE-0500 -0.706268
FASTDGN00 |WAR| 318453|2010-03-14 05:49:44.166499| FUNCTWARNING >
FunctWarning CHCURRAVERAGE-0500 -0.747349
FASTDGN00 |WAR| 318454|2010-03-14 05:49:44.178260| FUNCTEMERGENCYST > CHCURRAVERAGE-0500 = -0.79613 [/home/aoacct/src/DiagnApp/Funct.h:258]
FASTDGN00 |INF| 318455|2010-03-14 05:49:44.178290| ADAM > Adam: disabling coils...
FASTDGN00 |INF| 318456|2010-03-14 05:49:44.178968| ADAM > Adam: coils succesfully disabled
FASTDGN00 |WAR| 318457|2010-03-14 05:49:44.179046| FUNCTWARNING >
FunctWarning CHCURRAVERAGE-0530 -0.731983
FASTDGN00 |ERR| 318458|2010-03-14 05:49:44.180770| FUNCTALARM >
FunctAlarm CHINTCONTROLCURRENT-0500 -0.717208
FASTDGN00 |WAR| 318459|2010-03-14 05:49:44.191209| FUNCTEMERGENCYST > CHCURRAVERAGE-0000 = -0.8 [/home/aoacct/src/DiagnApp/Funct.h:258]
==========
mirror left in TSS during the rest of the night. TSS disabled at about 14:55 (local morning)
--
ArmandoRiccardi - 14 Mar 2010