Simulation data for Padova group: phase residuals at different magnitudes and seeing.

Tracknum Mag Seeing SR Time (s)
20150701_143246 10 0.80 68.96 0.60
20150701_143358 10 0.60 77.38 0.60
20150701_143802 10 0.60 78.42 5.00
20150701_144111 10 0.80 69.89 5.00
20150701_172309 10 0.60 77.72 5.00
20150701_172602 10 0.80 69.19 5.00
20150702_094406 12 0.60 54.59 5.00
20150702_094535 12 0.80 37.74 5.00

Archiving

Data has been archived on /aodata/simul_archive/SHARK

Code for above log_twiki:

dir = '/aodata/simul_archive/SHARK/data'
tracknums = file_search(dir+path_sep()+'201507*')
for idx=0,n_elements(tracknums)-1 do tracknums[idx] = file_basename( tracknums[idx])
columns = orderedhash()
columns['tracknum'] = { name: 'Tracknum', value: 'tracknum',                        format:''}
columns['seeing']   = { name: 'Seeing',   value: 'params.seeing.constant',          format:'(f4.2)'}
columns['mag']      = { name: 'Mag',      value: 'params.pyramid_source.magnitude', format:''}
columns['sr']       = { name: 'SR',       value: 'mean(srH[100:*])*100',            format:'(f5.2)' }
columns['time']     = { name: 'Time (s)', value: 'params.main.total_time',          format:'(f5.2)' }
data2restore = ['srH']
output = make_log_twiki( dir, tracknums, columns, data2restore, /twiki)



-- AlfioPuglisi - 28 Oct 2015
Topic revision: r1 - 28 Oct 2015, AlfioPuglisi
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.