Data of the coma needed for collimation:

drwxrwxrwx 2 aosup aosup 4096 Nov 20 20:36 20121120_203603
drwxrwxrwx 2 aosup aosup 4096 Nov 20 20:36 20121120_203649

Found a problem with NAS fiber: switch bcu going crazy (DSP get stuck).

Spare solved the problem.

Attuatore 635 jumped:
adsecarb.L         |INF|       173|2012-11-21 00:02:02.985688|   COMMANDHANDLER > Command Set Flat AO (code 2009) successfully completed
adsecarb.L         |ERR|       174|2012-11-21 00:32:05.733606|     ALERTHANDLER > Received an ERROR alert! Forcing Failure state.
adsecarb.L         |ERR|       175|2012-11-21 00:32:05.733673|     ALERTHANDLER > Alert message: COILS DISABLED from fastdiagn.L
adsecarb.L         |INF|       176|2012-11-21 00:32:05.735605|   COMMANDHANDLER > FSM (status: Failure) has received command 2002 (Recover failure)
adsecarb.L         |ERR|       177|2012-11-21 00:32:05.768826|     ALERTHANDLER > Received an ERROR alert! Forcing Failure state.
adsecarb.L         |ERR|       178|2012-11-21 00:32:05.768861|     ALERTHANDLER > Alert message: COILS DISABLED from fastdiagn.L
adsecarb.L         |ERR|       179|2012-11-21 00:32:05.798754|     ALERTHANDLER > Received an ERROR alert! Forcing Failure state.
adsecarb.L         |ERR|       180|2012-11-21 00:32:05.798788|     ALERTHANDLER > Alert message: COILS DISABLED from fastdiagn.L
adsecarb.L         |INF|       181|2012-11-21 00:32:05.848199|     ALERTHANDLER > Received from masterdiagnostic.L a DumpSaved alert with filename /home/aosup/adopt/log/current/ADAPTIVE-SECONDARY_00001353454325_20121121_003205.log

Seen from PROCESS_DUMP:
AdOpt>print, process_dump(file, /nosav)
% Program caused arithmetic error: Floating underflow
% Detected at MOMENT            143 /usr/local/itt/idl71/lib/moment.pro

-- PROCESS DUMP START --
Wed Nov 21 00:59:50 2012
Get info from housekeeper.L variables...done
Get info from masterdiagnostic.L dump file: ADAPTIVE-SECONDARY_00001353454325_20121121_003205.log...dump loaded.
Get info from fastdiagn.L variables...done
Get info from fastdiagn.L variables...done
Fam: CHCURRAVERAGE in Alarm over indexes: 225 226 227 240 241 242 253 254 257 258 259 337 338 339 352 353 365 368 369 370 377 378 379 380 382 383
Fam: CHDISTAVERAGE in Alarm over indexes: 635
Fam: CHINTCONTROLCURRENT in Alarm over indexes: 227 240 241 242 253 254 258 259 271 338 339 365 368 369 370 377 378 379 380 382 383 448
Fam: CHDISTRMS in Alarm over indexes: 635
No variables in Alarm for family: CHCURRRMS
No variables in Alarm for family: MODES
No variables in Alarm for family: CHNEWDELTACOMMAND
No variables in Alarm for family: CHFFCOMMAND
No variables in Alarm for family: CHFFPURECURRENT
Get info from housekeeper.L variables configuration...done
Get info from adamhousekeeper.L variables...done
Get info from housekeeper.L variables...done
Get info from adamhousekeeper.L variables...done
Adam watchdog not expired.
Ethernet connection watchdog on Switch BCU not expired.
Ethernet connection watchdog on Crate BCU not expired.
All global counters are progressing
DSP board watchdog not expired.
Distance threshold check analysis result:
Not stable capacitive sensor on CH ID: 003 011 015 018 027 030 032 043 047 051 055 059 063 067 071 075 079 083 087 091 095 099 103 107 111 115 123 127 136 152 160 171 172 179 183 187 191 195 199 203 207 211 215 219 223 226 235 238 259 267 271 275 279 282 285 291 295 299 303 307 311 315 319 323 327 331 335 377 382 385 400 406 411 415 419 427 431 435 439 443 447 451 459 463 466 475 477 483 491 495 499 503 507 511 515 519 523 527 531 535 539 543 547 551 555 559 563 571 575 593 603 606 610 613 619 621 627 631 635 639 643 647 651 655 659 663 667 671 (times: 17281728172816301728163014361727172717271727172817271728172817281728172717271727172717271727172717271730173017301438143914391730143917301730173017301730172917301730173017301730173016291726162917261726172617261726162915411726172617261726172617261726172617261726172617261535163215351439163217291729172917291729172917291729172917291729172916331730153617291729172917291729172917301729172917291729172917291729172917291729172917291733173317331539173316361636153917331539173317331733173317331733173317331733173317331733)
Consider to remove the actuators with highest fault frequency from the close loop list.
Consider to remove the other detected actuators from the integrator control loop list.
Temperature check passed with no issues found.
OVERCURRENT probability for TOTAL PUSH CURRENT:  42.2%
OVERCURRENT probability for TOTAL PULL CURRENT:   0.0%
OVERCURRENT probability for SINGLE CRATE TOTAL CURRENT:  24.2%
-- PROCESS DUMP END --
       0

KL UPDATE

After removing some actuator, the m2c,fits were updated in order to keep 0 force on slaves. /towerdata/adsec_calib/M2C/KL_MAG585_20110706/m2c.fits

IDL> m2c = readfits(m2cf)
IDL> offmat = readfits('/home/aosup/Source/Magellan/calib/adsec/585m/data/ff_matrix.fits')
IDL> ocl = readfits('/home/aosup/Source/Magellan/calib/adsec/585m/data/ff_list.fits')
IDL > slaves = adsec.mir_act2act[indgen(total(adsec_shell.n_act_ring[0:3]))] 
IDL> print, intersection(slaves, adsec.act_w_cl, slcl)

IDL> new = adsec.ff_matrix ## m2c
IDL> old=new*0 & old[*,ocl] = offmat ## m2c[*,ocl] 
IDL> new_slaved = adsec.ff_matrix ## slave_commands(slcl,m2c)

IDL> print, minmax(old[*, slcl])
      -5.9442593       6.6274363
IDL> print, minmax(new[*, slcl])
      -9169.4964       9541.0173
IDL> print, minmax(new_slaved[*, slcl])
      -5.8292135       6.4782414
IDL> writefits, '/towerdata/adsec_calib/M2C/KL_MAG585_20110706_UPDATED_20121120/m2c.fits', slave_commands(slcl,m2c)

ASTIGMATISM

Possible issue with the astigmatism like LBT. @68 deg: povilas says -1.6 Z6

Verified the computation of the offload modes applying the zernikes by hand without update the reference position of the fastdiagnostic.

@Wed Nov 21 06:43:14 CET 2012 act 635 jumped stable. removed.

after set Wed Nov 21 06:58:57 CET 2012

Problem around act 635 : VULCANO EFFECT on 655 72 634!!! Removed ICC from that actuators and waiting....

  • Volcano effect on around 635:
    Screen_shot_2012-11-21_at_03.08.05_AM.png

Time for jumps in COMA:

BUCO di misure dalle 5.40 alle 5.55 UT -> CET dalle 6.40 alle 6.55 - 05.28 UT first jump => 06.28 CET (2 meas) - 05.48 UT first jump => 06.48 CET (

5.40 alle 6.17 non vanno bene - GUIDER

PUPIL WOBBLING TEST

Executing: muovileggirot_plot, "/home/aosup/adopt/measures/MuoviLeggiRotatoreTT/20121120_215436", 15

Result: diameter about 4 pixels..

Retrieved M2C from /towerdata/adsec_calib/M2C/KL_MAG585_20110706:

-- MarcoXompero - 20 Nov 2012
Topic revision: r7 - 21 Nov 2012, MarcoXompero
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding Foswiki? Send feedback