Found actuator DSP#635 not working after shell mount. Fixed by Mandri lifting the distribution board by inserting an extra plastic washer between CP and DB. Replaced a plastic washer with a metal washer on top of the DB.

Start slew test @ Thu May 24 21:37:36 CEST 2012

Thu May 24 21:40:58 CEST 2012: 164

Thu May 24 21:44:57 CEST 2012: 20 deg elevation. all ok.

Thu May 24 21:48:01 CEST 2012: start going down

Thu May 24 21:49:38 CEST 2012: end

Thu May 24 21:50:29 CEST 2012: start slew test

Thu May 24 21:50:29 CEST 2012: 164 + 242, 252 TBV -> remove ICC

Thu May 24 21:57:34 CEST 2012: end.

Decided to repeat the test without removing ICC to verify the behavior.

Thu May 24 22:01:05 CEST 2012: start again slew test

Thu May 24 22:02:52 CEST 2012: 377 little jump (ca 0.01) -> remove ICC

Thu May 24 22:07:42 CEST 2012: 240 (->remove ICC)

Thu May 24 22:16:14 CEST 2012: 377=

Mario ha testato gli accelerometri: sono tutti funzionanti sia i canali che gli accelerometri,

Controllo il sw 1.01 accelerometer con mario

Da fare updatare il cvs a Jared: set_accelerometer per inizializzare bene (da fixare anche unita' B!!!!)

-- MarcoXompero - 24 May 2012
Topic revision: r4 - 25 May 2012, MarcoXompero
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding Foswiki? Send feedback