Astatic levers have been untightened

RB up

Put re-clocking tools

initial load 4KG/m(Ref-hole: 1.171)

started with 8Kg/m (was 16 on unit A) -> contacts of actuators less stiff of unit A. (Ref: 1.175)

Unbolted screws:

1 side (seems to be the rotation center) (Ref: 1.174) (torque: ---)

3 side ( Ref: 1.175, torque: 9-10Nm)

2 side ( Ref: 1.175, torque: 10-11Nm)

central ( Ref: 1.143, torque: <6.5Nm)

New Reference: 1.145

Torque load moved from 8-8kg/m to 7-6Kg/m (side 2, side 3) Ref: 1.145

New torque 10-10Kg/m. -> ...massage.... -> Ref:1.368 ->Torque fall 10-9 Kg/m

New torque 12-12 Kg/m -> ...massage... -> Ref. 1.415 -> Torque fall 11-11 Kg/m

New torque 15-15 Kg/m -> ...massage... -> Ref. 1.426 -> Torque fall 13-13.5 Kg/m

New torque 17-17 Kg/m -> ...massage... -> Ref. 1.467 -> Torque fall 16-16.5 Kg/m-> ...massage... -> 1.380 -> Torque fall 15-15 Kg/m

New torque 17-17 Kg/m -> ...massage... -> Ref. 1.403 -> Torque fall 16.5-16 Kg/m

decentering pushing direction of 544 MIR to center

Bolted screws @ 10N/m: side 1 - Ref: 1.407, side 3 - Ref. 1.403 , side 2 - Ref. 1.400 + central - Ref. 1.402

De-loading torque: from 16 to 4. Ref 1.394

Final measure: 1.390

End

-- RunaBriguglio - 21 Jun 2011
Topic revision: r2 - 21 Jun 2011, RunaBriguglio
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding Foswiki? Send feedback