-- RunaBriguglio - 14 Mar 2011

Images production of IF data ended at 7:55 am.

As a first quality check, the IntMat was created (to allow a quick modes visualization). The the flattening procedure was executed.

Flattening with 51x OIMat

Electrical data: 20110314_081205/flattening_result.sav

Optical data: 20110314_081205_flat650modes.h5
OIMat Electrical data Optical data WFE RMS Notes
20110311_181658 20110314_081205/flattening_result.sav 20110314_081205_flat650modes.h5 25 nm  
20110311_181658 20110314_082202/flattening_result.sav 20110314_082202_flat650modes.h5 24nm 30 sec int
20110311_181658 20110314_083002/flattening_result.sav 20110314_083002_flat650modes.h5 24nm 120sec int

Chopping optical test

Resume of procedure:

Hexapod aligment:

delta HP position, corresponding to 1um applied tilt: 0.76848145 2.0383301 1.1657959 -0.49224854 0.079896545, 0

flattening procedure executed at +25um tilt. electrical data:

Verification of KL basis

Modes Tracknum notes Amp nm
0-29 20110314_154224 100
30-59 20110314_154355 100
60-89 20110314_154554 100
90-119 20110314_154802 90
120-149 20110314_154946 70
150-179 20110314_155133 35
180-209 20110314_155328 30
210-239 20110314_155509 30
240-269 20110314_155658 27
270-299 20110314_155903 27
300-329 20110314_160428 25
330-359 20110314_160600 20
360-389 20110314_160736 20
390-419 20110314_160913 18
420-449 20110314_161135 18
450-479 20110314_161321 15
480-509 20110314_161457 15
510-539 20110314_161633 15
540-569 20110314_161825 15
570-599 20110314_162020 15
600-629 20110314_162155 15