-- RunaBriguglio - 11 Mar 2011

Resume of collected problems

We experienced a number of problems both sampling the optical IF and collecting FF data. such problems seem to be related to the modes definition (see previous log for optical results, and through the following for the electrical)

While collecting ff data, both zonal and modal, the last 3 modes were not applied. This was verified

Activity

FF_MATRIX acquisition: 1 iteration, modal, 650 working acts: tracknum = 20110311_102733

the last 3 modes are empty (

Marco found that the SWITCH_MAP.ENABLEACCCORRECTION bit set to 2: this corresponds to clearing up the reconstructor gain for the last 3 modes (see doc. 641A006E_ElectronicDesign_ext.doc) -----> modes applied are empty

A check was inserted in ff_acquire_v2, to verify that the bit is set to 0 (modes are not affected in any way)

New acquisition of FF_MATRIX: 650 modes, zonal: tracknum= 20110311_105554. the last 3 modes are not empty. the problem seems to be fixed

New acquisition of FF_MATRIX: 650 modes, 5 iterations, modal, tracknum= 20110311_111051. no residuals on act 147

This new FF_MATRIX is now used as system FF (stored in configuration).

New acquisition of FF_MATRIX (with new ff linked), for verification: 1 iteration, modal, tracknum= 20110311_120059.

New acquisition of FF_MATRIX, with new Accelerometers software re-enabled: tracknum= 20110311_123655: no missing modes ---> acc software is not a problem

Calibration

New acquisition of FF_MATRIX: 650 modes, modal, 20 iterations: tracknum= 20110311_130523

New OptIntMat:
Modes Tracknum
0-250 20110311_155749
251-500 20110311_155921
501-649 20110311_160058

New IF sampling for fernando

Modes Tracknum Notes
0-14 20110311_181658  
15-29 20110311_181841  
30-44 20110311_182057  
45-59 20110311_182507  
60-74 20110311_182703  
75-89 20110311_182917  
90-104 20110311_183054  
105-119 20110311_183258  
120-134 20110311_183447  
135-149 20110311_183632  
150-164 20110311_183806  
165-179 20110311_184018  
180-194 20110311_184222  
195-209 20110311_184620  
210-224 20110311_185004  
225-239 20110311_185322  
240-254 20110311_185513  
255-269 20110311_185646  
270-284 20110311_185834  
285-299 20110311_190049  
300-314 20110311_190317  
315-329 20110311_190455  
330-344 20110311_190643  
345-359 20110311_190820  
360-374 20110311_191037  
375-389 20110311_191229  
390-404 20110311_191424  
405-419 20110311_191610  
420-434 20110311_191743  
435-449 20110311_191940  
450-464 20110311_192113  
465-479 20110311_192253  
480-494 20110311_192509  
495-509 20110311_193057  
510-524 20110311_192846  
525-539 20110311_193309  
540-554 20110311_193525  
555-569 20110311_193752  
570-584 20110311_194114  
585-599 20110311_194406  
600-614 20110311_194553  
615-629 20110311_194741  
630-644 20110311_194927  
645-649 20110311_195116  
Topic revision: r3 - 11 Mar 2011, RunaBriguglio