Test: startup processi, start
AdSecMirGUI, power on da
AdSecControl ---> housekeeper crash -> BUG235
re-start housekeeper
FSM_SET_FLAT from GUI: -> "doppio" set della shell e FAILURE del ADSECARB a shell settata. => fixed
Verificata correttezza impostazione accelerometri. in attesa di Mario per il bug.
test rigidezza membrana: nessun problema fino a 25 gradi set and rip. RIp a 20 gradi con leggera rotazione.
Improvement script acquisizione matrice di FF. -> salvataggio parziale dei dati TESTED, riduzione TBV
Found watchdog DSP expired on A unit AFTER cooling failure at telescope:
idlctrl.R.00001293728632.log:idlctrl.R |INF| 476|2010-12-22 11:07:54.380626| MAIN > . Watchdog expired for DSP ID: All(#All)
idlctrl.R.00001294960765.log:idlctrl.R |INF| 7660|2011-01-13 18:20:33.940048| MAIN > . Watchdog expired for DSP ID: 042 043(#002)- Consider the dsp boards replacement
idlctrl.R.00001296761969.log:idlctrl.R |INF| 3606|2011-01-28 11:33:45.026819| MAIN > . Watchdog expired for DSP ID: 040 041 042 043(#004)- Consider the dsp boards replacement
idlctrl.R.00001297458275.log:idlctrl.R |INF| 1300|2011-02-04 23:59:16.970791| MAIN > . Watchdog expired for DSP ID: 040 041 042 043(#004)- Consider the dsp boards replacement
idlctrl.R.00001297458275.log:idlctrl.R |INF| 1323|2011-02-05 01:04:09.019908| MAIN > . Watchdog expired for DSP ID: 040 041 042 043(#004)- Consider the dsp boards replacement
idlctrl.R.00001297458275.log:idlctrl.R |INF| 1347|2011-02-05 03:05:04.336777| MAIN > . Watchdog expired for DSP ID: 040 041 042 043(#004)- Consider the dsp boards replacement
idlctrl.R.00001297458275.log:idlctrl.R |INF| 1371|2011-02-05 03:05:08.667804| MAIN > . Watchdog expired for DSP ID: 040 041 042 043(#004)- Consider the dsp boards replacement
idlctrl.R.00001297458275.log:idlctrl.R |INF| 1394|2011-02-05 03:17:21.539595| MAIN > . Watchdog expired for DSP ID: 040 041 042 043(#004)- Consider the dsp boards replacement
idlctrl.R.00001297458275.log:idlctrl.R |INF| 1416|2011-02-05 04:45:54.882693| MAIN > . Watchdog expired for DSP ID: 040 041 042 043(#004)- Consider the dsp boards replacement
idlctrl.R.00001297458275.log:idlctrl.R |INF| 1438|2011-02-05 05:00:17.841887| MAIN > . Watchdog expired for DSP ID: 040 041 042 043(#004)- Consider the dsp boards replacement
idlctrl.R.00001297458275.log:idlctrl.R |INF| 1460|2011-02-05 05:18:10.594326| MAIN > . Watchdog expired for DSP ID: 040 041 042 043(#004)- Consider the dsp boards replacement
idlctrl.R.00001297458275.log:idlctrl.R |INF| 1482|2011-02-05 05:45:12.938753| MAIN > . Watchdog expired for DSP ID: 040 041 042 043(#004)- Consider the dsp boards replacement
idlctrl.R.00001297458275.log:idlctrl.R |INF| 1505|2011-02-05 05:49:31.413708| MAIN > . Watchdog expired for DSP ID: 040 041 042 043(#004)- Consider the dsp boards replacement
idlctrl.R.00001297458275.log:idlctrl.R |INF| 9273|2011-02-07 08:43:17.637475| MAIN > . Watchdog expired for DSP ID: 042 043(#002)- Consider the dsp boards replacement
--
MarcoXompero - 04 Mar 2011