-- RunaBriguglio - 16 Dec 2010

Acquisition of missing modes

4D interferometer re-mounted in tower:! the mask was changed, so we captured the missing modes using both a new mask and the old one



modified 4D mask: config file (20101124) replaced by 20101216
tracknum modes notes
20101216_093611 225 239  
20101216_093741 240 254  
20101216_094000 240 254  
20101216_094141 240 254 migliore
20101216_094315 255 269 noise on upper_left-corner
the folding mirror was moved to match 20101124 mask:

tracknum modes notes
20101216_100225 225 239
20101216_100556 240 254
20101216_100722 240 254
20101216_100849 255 269

Intmat (modal basis) complete series

Here are listed the tracknum that compose the final modal basis:

['20101207_133733','20101207_133931','20101207_134139','20101207_134403','20101207_135419','20101207_135620','20101207_135742','20101207_135933',

'20101207_140050','20101207_140406','20101207_140609','20101207_140755','20101207_140920','20101207_141430','20101207_141641','20101207_141846',

'20101216_100722','20101207_142050','20101207_142211','20101207_142331','20101207_142459','20101207_142737','20101207_142913','20101207_143121',

'20101207_143310','20101207_143454','20101207_143635','20101207_143815','20101207_143945','20101207_165356','20101207_165528','20101207_144358',

'20101207_144715','20101207_144855','20101207_145024','20101207_145157','20101207_145344','20101207_145514','20101207_145637','20101207_145809',

'20101207_145951','20101207_150208','20101207_150653']

! please note that the missing modes set was replaced by 20101216_100722, i.e. folding mirror moved to match old mask

Intmat verification

New intmat produced and verified using it as a flattening command:

data in /flat/20101207_133733/flat_data_640modes

optical result:30nm: 20101216_104217_flat640modes.h5

electrical result: 20101216_104217/flattening_result

Test of old shapes reproducibility

tracknum is /flat/tracknum/flattening_result.sav

Id is to be verified (calibrated-applied??)
Shape ID tracknum Optical data WFE 4 WFE 15 max mode
S1 20101124_210021 20101216_111400_load_shape_20101124_210021.h5 413 62 351
S0 20101123_143507 20101216_111700_load_shape_20101123_143507 138 33 377
S2 20101126_194959 20101216_111900_load_shape_20101126_194959 428 64 351
S12 20101127_140236 20101216_112100_load_shape_20101127_140236 270 48 371
S01 20101129_115928 20101216_112400_load_shape_20101129_115928 96 34 374
S21 20101127_001824 20101216_112800_load_shape_20101127_001824 270 45 370
S20 20101128_162714 20101216_113300_load_shape_20101128_162714 72 49 325
S12 20101125_202023 20101216_133000_load_shape_20101125_202023 420 66 374
S01 20101124_135901 20101216_133600_load_shape_20101124_135901 447 71 374
S00 20101123_114139 20101216_133900_load_shape_20101123_114139 140 34 374
Topic revision: r3 - 20 Dec 2010, RunaBriguglio
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.