test on tubone cooling noise on interferogram measurements (any astigmatism addiction??)

acquisition with cooling on: 20101120_113600_noiseATTon

cooling is stopped (5 minutes wait to reach a stable condition)

acquisition with cooling off: 20101120_114300_noiseATToff

test on Sw BCU trigger offset

data saved in /flattening/test_offset/resXX.h5, resXXa.h5

tracknum offset res trefoil (rms) (Wv from 4D)
20101120_120448 1 0.4, -0.09
20101120_124926 1 0.42; -0.08
20101120_123855 2 0.2, -0.04
20101120_124650 2 0.2; -0.04
20101120_123642 3 -0.06; 0
20101120_125035 3 -0.06; 0.02
20101120_122401 4 0.04; -0.01
20101120_125148 4 0.05; -0.02
20101120_120704 5 0.33, -0.04
20101120_125337 5 0.35; -0.05
20101120_130141 6 0.42; -0.1
20101120_130207 6 0.42; -0.12
20101120_130252 7 0.22; -0.04
20101120_130328 7 0.19; -0.06
20101120_130429 8 -0.04; -0.01
20101120_130459 8 nodata????
20101120_130523 9 0.06; -0.01
20101120_130603 9 0.06; -0.01

--++ test on 4D delay the Sw BCU offset is 1 (as usual); initial 4d delay is 0.388 ms

tracknum delay bcu offset residual 3foil
20101120_133722 0 1  
20101120_134356 2 1  
20101120_134433 4 1  
20101120_134519 6 1  
20101120_134553 8 1 no data???
20101120_143807 8 1  
20101120_134916 0 4  
20101120_135003 2 4  
20101120_135053 4 4  
20101120_135132 6 4  
20101120_135206 8 4  