-- RunaBriguglio - 19 Nov 2010

ff_pure_current is not cleared at the end of the application of modes.

to test the behavior, the following command lines was execute. results are shown in the plot below. !!!! a variable offset was added to the plots in order to separate the data: it is not a real offset, but just a graphical adjustment.

HP position at the end of the day:

221.80766 1953.5101 1917.5134 45.092434 97.034393 -0.12897143

1) test on application of 10 modes, at changing number of iterations

for i=1, 7 do begin&print, i4d_opt_intmat(500, 510, average=i*3, ffpure=a)&ffp[*,i-1]=a&endfor

resulting in the following data file


/towerdata/adsec_calib/20101119_194715_ffp.sav

the ff_pure_current is increasing after each step

2) test on the application of just 3 modes, with changing number of iterations. ff_p_curr is lower than the previous result

for i=1, 7 do begin&print, i4d_opt_intmat(500, 502, average=i*3, ffpure=a)&ffp[*,i-1]=a&endfor

20101119_195314
.......

dati:/20101119_194715_ffp.sav

3) test on the application of just 1 mode, at changing number of iterations. ff_p_curr is 0

for i=1, 7 do begin&print, i4d_opt_intmat(500, 500, average=i*3, ffpure=a)&ffp[*,i-1]=a&endfor

20101119_195854

dati:20101119_195854_ffp.sav

4) test on the application of a large number of modes, with few iterations. large ff_p_curr

for i=1, 7 do begin&print, i4d_opt_intmat(500, 500+i*10, average=3, ffpure=a)&ffp[*,i-1]=a&endfor

20101119_202010

dati:20101119_202010_ffp.sav

5) test on the application of just 2 modes, with a large number of iterations (70). low ff_p_curr

for i=1, 7 do begin&print, i4d_opt_intmat(500, 502, average=i*10, ffpure=a)&ffp[*,i-1]=a&endfor

20101119_202639

dati:20101119_202639_ffp.sav