-- RunaBriguglio - 22 Oct 2010

set_flat(/ff)

set_icc(5, 10)

setpistoncurrent(10)

3slew

start 110950

verify #48: maximum differential movement

stop 111400 no jumps (same configuration of last test, same results)

111800: 174, 339, 448 reinserted into the loop (were excluded from current)

set_flat(/ff), set_icc, setpistoncurrent

3slew 112500

stop 113117 no jumps, no warning #452 ChIntCtrlCurrent

449, 454, 460 re-inserted into the ICC list

3 slew 115620

stop..... no errors

act wo icc list: all actuators reinserted (except for 8 24 51 122 162 170, that were removed in april 2010)

slew 120610

shell in rest position, slew to horizon for jumping acts

1/8 wave loaded, slew with shell rip

152250

stop 153000

shell set, high gains no oscillation found

setpistoncurrent(20)

slew start 154600

rip 154830 (oscillation??)

set again, setpistoncurrent(20)

3 slew start 155100

stop 155830