from 10:30 to 11:30 the shell TS5 has been dismounted:
  • NO detached magnets
shell re-installed without miniskirt. central membrane screws tightened

160000 fsm_set_flat(/ff) no gain because miniskirt is missing. central membrane screws losened.

test of shell rotation:
  1. rotation by hand: 0.5mm (on the edge), but there is still clearance between the magnets and their cold plate holes
  2. then shell ripped
161000 screws tightened, then fsm_set_flat(/ff), then standard procedure:
  1. screws losened
  2. screws tightened
verify pos and curr behaviour 20101015_161000 to 161800

20101015_162300 1/8 reference wave loaded

beam for shell installation not removed

slewing test

2011015_163115 start 90deg

20101015_163325 0deg

act #337 not stable: jumps on the capsens readings

20101015_164300 start going down form 0deg 20101015_165640 stop @90deg

#114, 194, 396 jumped

20101015_165830 start new slow from 90 deg 20101015_170000 stop @0deg

#347, 451 jumped

20101015_170120 start going down from 0deg 20101015_170241 stop @90 deg

2 additional slews to detect jumping acts

20101015_170440 start from 90deg

20101015_170545 0deg

20101015_170610 90deg

20101015_170732 0 deg

20101015_170800 90 deg end of slew

found some jumping actuators: # 114 173 175 194 259 337 344 347 377 391 396 407 451
598

a new series of slew is performed to detect other jumping acts

start of 2 slew 20101015_173000 90 deg

stop 20101015_173100 0deg

20101015_173123 90deg

20101015_173200 0deg

20101015_173228 90deg

20101015_173315 0deg

20101015_173339 90deg

20101015_173426 0deg

20101015_173447 90deg

jumping acts (3 more than before): # 114 171 173 175 194 259 278 311 337 344 347 377 391
396 407 451 598

additional slews

180000 90deg

180100 0deg

180155 90deg

180225 0deg

180245 90deg

180308 0deg

180327 90deg

the series of jumping act is constant, and it is shown in the image below

jumping_acts2011015_6slew.JPG

the jumping actuators have been removed from the position.

20101015_182200 fsm_set_flat(/ff)

new series of elevation slew with shell set (ICC disabled because of keyword /ff) and without setting the pistoncurrent (forgotten)

20101015_182320 start at 90deg

shell ripepd because of act#51

fastdiagn.L |ERR| 57262|2010-10-15 18:23:45.783533| FUNCTEMERGENCYST > CHCURRAVERAGE-0051 = -0.8 [/home/adopt/work/AO/releases/20100805adsec/Diag
nApp/Funct.h:257]
fastdiagn.L |INF| 57263|2010-10-15 18:23:45.783577| ADAM > Adam: disabling coils...
fastdiagn.L |INF| 57264|2010-10-15 18:23:45.784317| ADAM > Adam: coils succesfully disabled

20101015_184200 fsm_set_flat(/ff) &set_icc & setpistoncurrent(10)

slew:

20101015_184410 start at 90deg

20101015_185640 stop at 20deg the shell is still set

20101015_195745 going down

185850 sto at 90deg

185900 start at 90deg

185955 stop at 20deg

190040 stop at90deg

the shell is still set, one single warning #280 intcontrol current

-- ArmandoRiccardi - 15 Oct 2010
Topic revision: r3 - 15 Oct 2010, ArmandoRiccardi
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding Foswiki? Send feedback