from 10:30 to 11:30 the shell TS5 has been dismounted:
shell re-installed without miniskirt. central membrane screws tightened
160000 fsm_set_flat(/ff) no gain because miniskirt is missing. central membrane screws losened.
test of shell rotation:
- rotation by hand: 0.5mm (on the edge), but there is still clearance between the magnets and their cold plate holes
- then shell ripped
161000 screws tightened, then fsm_set_flat(/ff), then standard procedure:
- screws losened
- screws tightened
verify pos and curr behaviour 20101015_161000 to 161800
20101015_162300 1/8 reference wave loaded
beam for shell installation not removed
slewing test
2011015_163115 start 90deg
20101015_163325 0deg
act #337 not stable: jumps on the capsens readings
20101015_164300 start going
down form 0deg 20101015_165640 stop @90deg
#114, 194, 396 jumped
20101015_165830 start new slow from 90 deg 20101015_170000 stop @0deg
#347, 451 jumped
20101015_170120 start going down from 0deg 20101015_170241 stop @90 deg
2 additional slews to detect jumping acts
20101015_170440 start from 90deg
20101015_170545 0deg
20101015_170610 90deg
20101015_170732 0 deg
20101015_170800 90 deg end of slew
found some jumping actuators: # 114 173 175 194 259 337 344 347 377 391 396 407 451
598
a new series of slew is performed to detect other jumping acts
start of 2 slew 20101015_173000 90 deg
stop 20101015_173100 0deg
20101015_173123 90deg
20101015_173200 0deg
20101015_173228 90deg
20101015_173315 0deg
20101015_173339 90deg
20101015_173426 0deg
20101015_173447 90deg
jumping acts (3 more than before): # 114 171 173 175 194 259 278 311 337 344 347 377 391
396 407 451 598
additional slews
180000 90deg
180100 0deg
180155 90deg
180225 0deg
180245 90deg
180308 0deg
180327 90deg
the series of jumping act is constant, and it is shown in the image below
the jumping actuators have been removed from the position.
20101015_182200 fsm_set_flat(/ff)
new series of elevation slew with shell set (ICC disabled because of keyword /ff) and without setting the pistoncurrent (forgotten)
20101015_182320 start at 90deg
shell ripepd because of act#51
fastdiagn.L |ERR| 57262|2010-10-15 18:23:45.783533| FUNCTEMERGENCYST > CHCURRAVERAGE-0051 = -0.8 [/home/adopt/work/AO/releases/20100805adsec/Diag
nApp/Funct.h:257]
fastdiagn.L |INF| 57263|2010-10-15 18:23:45.783577| ADAM > Adam: disabling coils...
fastdiagn.L |INF| 57264|2010-10-15 18:23:45.784317| ADAM > Adam: coils succesfully disabled
20101015_184200 fsm_set_flat(/ff) &set_icc & setpistoncurrent(10)
slew:
20101015_184410 start at 90deg
20101015_185640 stop at 20deg the shell is still set
20101015_195745 going down
185850 sto at 90deg
185900 start at 90deg
185955 stop at 20deg
190040 stop at90deg
the shell is still set, one single warning #280 intcontrol current
--
ArmandoRiccardi - 15 Oct 2010