Analising turbulence data discovered bad behavior of 2 actuators: DSP# 2/381

Checking in the other data was discovered that actuators as very noisy (2/3 times respect to the others)

Removed from CL list and a new set of turbulence measurement was taken, simply recomputing the FF matrix.

Sudden power off due at : DSPPOWERTEMP-0063 = -115

Turbulence @90: 20100827_134007+20100827_134901

Turbulence @20: 20100827_144253+20100827_145230

Turbulence @45: 20100827_150138+20100827_151058

Now all tracking data are ok (tested on 90 deg)

Turbulence plot reduced in $ADOPT_MEAS/Magellan-Plot

FF matrix plot generated.

Noise plot are missing.

-- MarcoXompero - 27 Aug 2010