Simulation of Seeing Limited Acceptance Test
routine for reducing data:
$ADSEC_IDL_SOURCE/adsec_lib/adsec_utilities/acctest_sl_mode.pro
flattening command file: flat_data_wfs_calibrated.sav
after_load_shape_timestamp = '20091208_122216'
before_aogain_timestamp = '20091208_122458'
after_aogain_timestamp = '20091208_122513'
end_aogain_timestamp = '20091208_122609'
stdev:
CL bin1, 490 modes, gain 0.3:
after_load_shape_timestamp = '20091208_164840'
before_aogain_timestamp = '20091208_164948'
after_aogain_timestamp = '20091208_165112'
end_aogain_timestamp = '20091208_165345'
WFE stdev: 361nm (NO TT-Focus removed)
flattening command file: 600_modes_2009_08_10.sav
CL bin1, 490 modes, gain 0.3:
after_load_shape_timestamp = '20091208_170010'
before_aogain_timestamp = '20091208_170120'
after_aogain_timestamp = '20091208_170153'
end_aogain_timestamp = '20091208_170400'
WFE stdev: 541nm (NO TT-Focus removed)
Dominated by bistable actuator area
flattening command file: 600_modes_2009_08_10_after_jump.sav
CL bin1, 490 modes, gain 0.3:
after_load_shape_timestamp = '20091208_170811'
before_aogain_timestamp = '20091208_171045'
after_aogain_timestamp = '20091208_171100'
end_aogain_timestamp = '20091208_171524'
WFE stdev: 447nm (NO TT-Focus removed), 273nm (TT-Focus removed)
The process of filtering actuator forces failed because too many actuators to be filtered out
--
ArmandoRiccardi - 08 Dec 2009