LBT672b in the hub
  • new routine for setting the TS4 gains:
    • print, ramp_gain_script60TS4()

with no ICC and gains set as reported above, we measured:
  • step responces
  • noise test:
    • _TS4_60um_lin
    • _TS4_60um_nolin

enabled ICC:
  • print, set_icc(5., 10.)

and tested the time history (to be ready for the thermal test of tomorrow:
  • OK, worked properl. Can be used tomorrow.

started a drift measurement overnight at 20:01 (set _a on 2009_11_02):

assured that watchdog (adam and crate) is enabled

At 22:33 Stopped by housekeeper because excessive temperature of Cabinet (Switch BCU Power Temp)

  • Temperature plot during drift test:
    temperature_plots.png

Restarted a new drift test (set _b) on 2009_11_03 at 00:39

-- ArmandoRiccardi - 2009-11-02