C'e' ancora la logica che si blocca (ma a volte va, si prova per non modificare troppa roba

First attempt with the last logic release fit 2009026 because Mario found the system sometime correctly start up. Unable tu set shell for "carrying" of diagnostic data.

BCU logic changed (12.35 )(fixs a bug (timing delay + FIFO full)on masterdir of diagnostic buffer) but nothing happened.


Resume:

- modified on DSP fifo receiver reset (6.04e) -> "carrying" bug

- modified on DSP fifo receiver reset and FIFO time costrained in logic fitting -> "carrying" bug and difficult to startup (communication error)

- like previous but with new timing -> good startup but flink timeout error on setting and crates 2-3-4-5 not readable

- Flash back 6.04d (as 6.03+know bugs) and mantaining BCU (12.35) -> correctly started @ 16:00, working @19.00 till 19.30. probably gets stuck the diagnostic frames from bcu to adsec pc.

-- MarcoXompero - 2009-08-27
Topic revision: r5 - 28 Aug 2009, MarcoXompero
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.