Start session @11.00
  • Verified bcu logics to be the same of unit A
  • Mario restored the 6.04a logic (line 12 excel attacched in main)
  • sustained test started @12.0. Failed @13.45 with FL timeout error. There is no new logic stable
  • There was a single dsp board reset. crate 1 board 3 that was "swapped" with crate 1 board 10. So the problem seems to be related to single boards. Moreove, the only modification between 6.03 log and 6.04a logic is the "FIFO almost full" value changed.
  • The board was substituted with one spare tested in the past days on the system.
  • The "sustained" test started @16.15 and was stopped @1845 (but all ok)
  • Mario asked for testing ver 6.04c. The version was loaded and the system restarted. The test started @1900.
  • The test failed after a couple of hours. with FL timeout without any board reset with the "soft" mode (a reading unblockedthe system)

-- MarcoXompero - 2009-08-10
Topic revision: r5 - 11 Aug 2009, MarcoXompero
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.