You are here: Foswiki>FLAO Web>LbtTel (01 Jul 2015, AlfioPuglisi)Edit Attach

Logs and notes of FLAO #1 and #2 Commissioning after mounting on telescope

Notes about the system after October 2011 run

Oct2011Notes

Software TODO list @ telescope for Oct 2010

Software TODO list @ telescope for Oct 2010

Startup notes for AO system

AO System startup and Operation

FLAO#1 general reports (distributed daily by email)

Daily Reports of FLAO activity at LBTO

FLAO#1 and #2 detailed Activity Logs

Detailed Log of FLAO#1 and FLAO#2 activities at telescope

Automated error logs

Daytime To Do List

Configurations & RECs

Reference star list

IRTC Dark list

LBT672a specific Logs, Notes and ToDo list

Adaptive secondary mirror A detailed Logs

LBT672b specific Logs, Notes and ToDo list

Adaptive secondary mirror B detailed Logs

FLAO Data Analysis

All data reducted

- DATA 04-05-06 Apr 2010

Pupil position vs Rerotator rotation on sky

AdcData

Observation Preparation

RotationSpeedVsDeclination

InfoAGw

SW todo list @ telescope

TelToDoList

Help for dummy users of Elablib


ssh AOeng@adsecdx
aoidl

ao_init


set=obj_new('aodataset',from='20100606_000000',to='20100606_192300')
log_twiki, set

set->modalplot

ee=getaoelab(trucknum)

(ee->irtc())->plotJitter

ee->modalplot

set->modalplot

IDL commands to read master-dump files

aoidl

IDL> @startup

IDL> print, read_master_buffer_dump("$ADOPT_LOG/ADAPTIVE-SECONDARY_00001347939839_20120918_034359.log", data)
IDL> print, pack_master_data(data, "tmp.sav")
IDL> restore, /VERB, "tmp.sav"
% RESTORE: Portable (XDR) SAVE/RESTORE file.
% RESTORE: Save file written by AOeng@adsecsx.mountain.lbto.org, Tue Sep 18 03:46:49 2012.
% RESTORE: IDL version 7.1 (linux, x86).
% RESTORE: Restored variable: DISTAVERAGE.
% RESTORE: Restored variable: CURRAVERAGE.
% RESTORE: Restored variable: MODES.
% RESTORE: Restored variable: NEWDELTACOMMAND.
% RESTORE: Restored variable: FFCOMMAND.
% RESTORE: Restored variable: INTCONTROLCURRENT.
% RESTORE: Restored variable: FFPURECURRENT.
% RESTORE: Restored variable: SLOPES.
% RESTORE: Restored variable: WFSCOUNTER.
% RESTORE: Restored variable: MIRCOUNTER.
% RESTORE: Restored variable: WPOS.
% RESTORE: Restored variable: WCUR.

Help on use of PSF for alignment during calibration with RRH

PsfUseWithRrhHelp

My notes

print, read_var_wrap("AOS.R.HEXAPOD.ABS_POS", p, 10000)

Useful documents

Topic revision: r89 - 01 Jul 2015, AlfioPuglisi
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding Foswiki? Send feedback