Fibra da 200um di core

Fatto andare lo script dell'accoptance con seeing 0.8 e seep gain normale (TT+HO)
TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR band exp #frames disturb notes
20110516_133841 ??? 9.3 -2147483648 -2147483648 -1.00 -1.00 151120 1 500 990 0.4 0.4 3 118 ON 2.1 H 50 300 ON - Warning: Selected IRTC dark +94h old!
20110516_133952 ??? 9.2 -2147483648 -2147483648 -1.00 -1.00 151120 1 500 990 0.4 0.4 3 129 ON 2.1 H 50 300 ON - long stop of 77 frames at frame 1238
20110516_134104 ??? 9.2 -2147483648 -2147483648 -1.00 -1.00 151120 1 500 990 0.4 0.4 3 125 ON 2.1 H 50 300 ON  
20110516_134336 ??? 9.4 -2147483648 -2147483648 -1.00 -1.00 151120 1 500 990 0.4 0.4 3 109 ON 2.1 H 50 300 ON  
20110516_134448 ??? 9.2 -2147483648 -2147483648 -1.00 -1.00 151120 1 500 990 0.4 0.4 3 130 ON 2.1 H 50 300 ON  
20110516_134559 ??? 9.2 -2147483648 -2147483648 -1.00 -1.00 151120 1 500 990 0.4 0.4 3 130 ON 2.1 H 50 300 ON  
IDL string: ['20110516_133841','20110516_133952','20110516_134104','20110516_134336','20110516_134448','20110516_134559']

Test del modal gain con TT+HO1+ HO2

Torniamo per adesso al modal gain con TT+HO

abbiamo una fastidiosa oscillazione del frame del 39 che ci impedisce di fare la misura a mag10.5

Spegnamo il sistema e lo riaccendiamo e l'oscillazione sembra sparita, boh!!

misura mag 10.2 seeing 0.8" fibra 200um rec 400 modi

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR band exp #frames disturb notes
20110516_164011 ??? 10.3 -2147483648 -2147483648 -1.00 -1.00 110422 1 400 990 0.3 0.5 3 47 ON 1.7 H 100 150 ON - SR may be in error - Warning: Selected IRTC dark +100h old!
20110516_164058 ??? 10.3 -2147483648 -2147483648 -1.00 -1.00 110422 1 400 990 0.3 0.5 3 46 ON 1.7 H 100 150 ON - SR may be in error - Warning: Selected IRTC dark +100h old!
20110516_164144 ??? 10.3 -2147483648 -2147483648 -1.00 -1.00 110422 1 400 990 0.3 0.5 3 49 ON 1.7 H 100 150 ON - long stop of 114 frames at frame 1575 - SR may be in error
20110516_164323 ??? 10.6 -2147483648 -2147483648 -1.00 -1.00 110422 1 400 990 0.3 0.5 3 35 ON 1.7 H 100 150 ON - SR may be in error
20110516_164409 ??? 10.3 -2147483648 -2147483648 -1.00 -1.00 110422 1 400 990 0.3 0.5 3 45 ON 1.7 H 100 150 ON - SR may be in error
20110516_164456 ??? 10.2 -2147483648 -2147483648 -1.00 -1.00 110422 1 400 990 0.3 0.5 3 50 ON 0.0 H 100 150 ON - Background correction failed

misura mag 10.2 seeing 0.8" fibra 200um rec 300 modi

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR band exp #frames disturb notes
20110516_170612 ??? 10.2 -2147483648 -2147483648 -1.00 -1.00 151551 1 300 990 0.3 0.3 3 51 ON 1.7 H 100 150 ON - SR may be in error
20110516_170659 ??? 10.2 -2147483648 -2147483648 -1.00 -1.00 151551 1 300 990 0.3 0.3 3 50 ON 1.7 H 100 150 ON - SR may be in error
20110516_170748 ??? 10.2 -2147483648 -2147483648 -1.00 -1.00 151551 1 300 990 0.3 0.3 3 50 ON 0.0 H 100 150 ON - Background correction failed
20110516_170930 ??? 10.6 -2147483648 -2147483648 -1.00 -1.00 151551 1 300 990 0.3 0.3 3 36 ON 1.6 H 100 150 ON - SR may be in error
20110516_171017 ??? 10.4 -2147483648 -2147483648 -1.00 -1.00 151551 1 300 990 0.3 0.3 3 45 ON 0.0 H 100 150 ON - Background correction failed
IDL string: ['20110516_170612','20110516_170659','20110516_170748','20110516_170930','20110516_171017']

Messa fibra da 62.5um

-- EnricoPinna - 16 May 2011
  • mag105-fiber0_3arcsec.png:
    mag105-fiber0_3arcsec.png
Topic revision: r4 - 20 Sep 2011, EnricoPinna
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.