Performance test with script

During this run the Readout Noise was somewhat higher than usual due to some unknown external interference (RON between 9.5 at bin1 down to 5.6 at bin4).

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR band exp #frames disturb notes
20110510_132804 ??? 8.4 -2147483648 -2147483648 -1.00 -1.00 110422 1 400 990 0.4 0.6 3 265 ON 85.4 H 50 300 ON  
20110510_132915 ??? 8.4 -2147483648 -2147483648 -1.00 -1.00 110422 1 400 990 0.4 0.6 3 266 ON 82.3 H 50 300 ON  
20110510_133026 ??? 8.4 -2147483648 -2147483648 -1.00 -1.00 110422 1 400 990 0.4 0.6 3 266 ON 86.5 H 50 300 ON  
20110510_133257 ??? 8.5 -2147483648 -2147483648 -1.00 -1.00 110422 1 400 990 0.4 0.6 3 255 ON 88.3 H 50 300 ON  
20110510_133408 ??? 8.4 -2147483648 -2147483648 -1.00 -1.00 110422 1 400 990 0.4 0.6 3 266 ON 83.0 H 50 300 ON  
20110510_133519 ??? 8.4 -2147483648 -2147483648 -1.00 -1.00 110422 1 400 990 0.4 0.6 3 266 ON -1.0 ? -1 -1 ON  

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR band exp #frames disturb notes
20110510_134025 ??? 9.4 -2147483648 -2147483648 -1.00 -1.00 110422 1 400 990 0.4 0.8 3 104 ON 82.7 H 70 214 ON  
20110510_134120 ??? 9.4 -2147483648 -2147483648 -1.00 -1.00 110422 1 400 990 0.4 0.8 3 104 ON 82.7 H 70 214 ON  
20110510_134214 ??? 9.4 -2147483648 -2147483648 -1.00 -1.00 110422 1 400 990 0.4 0.8 3 107 ON 77.8 H 70 214 ON  
20110510_134416 ??? 9.5 -2147483648 -2147483648 -1.00 -1.00 110422 1 400 990 0.4 0.8 3 98 ON -1.0 ? -1 -1 ON  
20110510_134447 ??? 9.5 -2147483648 -2147483648 -1.00 -1.00 110422 1 400 990 0.4 0.8 3 100 ON 82.5 H 70 214 ON  
20110510_134542 ??? 9.4 -2147483648 -2147483648 -1.00 -1.00 110422 1 400 990 0.4 0.8 3 105 ON 83.7 H 70 214 ON  

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR band exp #frames disturb notes
20110510_144034 ??? 11.5 -2147483648 -2147483648 -1.00 -1.00 171951 2 153 991 0.3 0.4 3 63 ON 57.2 H 100 150 ON  
20110510_144117 ??? 11.5 -2147483648 -2147483648 -1.00 -1.00 171951 2 153 991 0.3 0.4 3 62 ON 56.4 H 100 150 ON  
20110510_144159 ??? 11.5 -2147483648 -2147483648 -1.00 -1.00 171951 2 153 991 0.3 0.4 3 62 ON -1.0 ? -1 -1 ON  
20110510_144318 ??? 11.6 -2147483648 -2147483648 -1.00 -1.00 171951 2 153 991 0.3 0.4 3 57 ON 50.3 H 100 150 ON  
20110510_144401 ??? 11.6 -2147483648 -2147483648 -1.00 -1.00 171951 2 153 991 0.3 0.4 3 59 ON 55.9 H 100 150 ON  
20110510_144443 ??? 11.5 -2147483648 -2147483648 -1.00 -1.00 171951 2 153 991 0.3 0.4 3 63 ON 56.6 H 100 150 ON  

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR band exp #frames disturb notes
20110510_145632 ??? 13.5 -2147483648 -2147483648 -1.00 -1.00 171410 3 66 200 1.3 1.5 6 110 ON -1.0 ? -1 -1 ON  
20110510_145702 ??? 13.5 -2147483648 -2147483648 -1.00 -1.00 171410 3 66 200 1.3 1.5 6 115 ON -1.0 ? -1 -1 ON  
20110510_145731 ??? 13.5 -2147483648 -2147483648 -1.00 -1.00 171410 3 66 200 1.3 1.5 6 114 ON 26.2 H 100 150 ON  
20110510_145910 ??? 13.6 -2147483648 -2147483648 -1.00 -1.00 171410 3 66 200 1.3 1.5 6 109 ON 25.1 H 100 150 ON  
20110510_145952 ??? 13.5 -2147483648 -2147483648 NaN -1.00 171410 3 66 200 1.3 1.5 6 112 ON 23.8 H 100 150 ON  
20110510_150035 ??? 13.5 -2147483648 -2147483648 -1.00 -1.00 171410 3 66 200 1.3 1.5 6 114 ON 24.0 H 100 150 ON  

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR band exp #frames disturb notes
20110510_150448 ??? 14.8 -2147483648 -2147483648 -1.00 -1.00 171410 3 66 200 0.9 1.0 6 34 ON 13.1 H 300 50 ON  
20110510_150519 ??? 14.7 -2147483648 -2147483648 -1.00 -1.00 171410 3 66 200 0.9 1.0 6 38 ON 13.2 H 300 50 ON  
20110510_150549 ??? 14.6 -2147483648 -2147483648 -1.00 -1.00 171410 3 66 200 0.9 1.0 6 41 ON 13.8 H 300 50 ON  
20110510_150700 ??? 14.7 -2147483648 -2147483648 -1.00 -1.00 171410 3 66 200 0.9 1.0 6 38 ON 12.4 H 300 50 ON  
20110510_150730 ??? 14.7 -2147483648 -2147483648 -1.00 -1.00 171410 3 66 200 0.9 1.0 6 40 ON -1.0 ? -1 -1 ON  
20110510_150800 ??? 14.6 -2147483648 -2147483648 -1.00 -1.00 171410 3 66 200 0.9 1.0 6 40 ON 13.2 H 300 50 ON  

Performance measurement with script

This time the Readout noise seems a bit better.

4:45 PM : the AOS crashed and was restarted manually.

Ron measure WFS all on except CUBE and LAMP

Bin: 1 - Framerate 990 Hz (2500 kpix/sec) - RON (e-): 8.82 (estimated) Bin: 2 - Framerate 990 Hz ( 800 kpix/sec) - RON (e-): 6.46 (estimated) Bin: 2 - Framerate 625 Hz ( 380 kpix/sec) - RON (e-): 4.78 (estimated) Bin: 2 - Framerate 400 Hz ( 380 kpix/sec) - RON (e-): 4.78 (estimated) Bin: 3 - Framerate 200 Hz ( 380 kpix/sec) - RON (e-): 4.98 (estimated) Bin: 4 - Framerate 300 Hz ( 335 kpix/sec) - RON (e-): 5.26 (estimated) Bin: 4 - Framerate 200 Hz ( 335 kpix/sec) - RON (e-): 5.25 (estimated) Bin: 4 - Framerate 105 Hz ( 335 kpix/sec) - RON (e-): 5.34 (estimated)

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR band exp #frames disturb notes
20110510_155444 ??? 8.3 -2147483648 -2147483648 -1.00 -1.00 110422 1 400 990 0.4 0.7 3 288 ON 84.2 H 50 300 ON  
20110510_155554 ??? 8.4 -2147483648 -2147483648 -1.00 -1.00 110422 1 400 990 0.4 0.7 3 272 ON 84.5 H 50 300 ON  
20110510_155704 ??? 8.4 -2147483648 -2147483648 -1.00 -1.00 110422 1 400 990 0.4 0.7 3 274 ON 83.0 H 50 300 ON  
20110510_155933 ??? 8.5 -2147483648 -2147483648 -1.00 -1.00 110422 1 400 990 0.4 0.7 3 259 ON 84.1 H 50 300 ON  
20110510_160043 ??? 8.4 -2147483648 -2147483648 -1.00 -1.00 110422 1 400 990 0.4 0.7 3 267 ON 85.2 H 50 300 ON  
20110510_160154 ??? 8.4 -2147483648 -2147483648 -1.00 -1.00 110422 1 400 990 0.4 0.7 3 266 ON 77.9 H 50 300 ON  

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR band exp #frames disturb notes
20110510_160839 ??? 9.5 -2147483648 -2147483648 -1.00 -1.00 110422 1 400 990 0.4 0.4 3 104 ON 79.7 H 70 214 ON  
20110510_160934 ??? 9.4 -2147483648 -2147483648 -1.00 -1.00 110422 1 400 990 0.4 0.4 3 106 ON -1.0 ? -1 -1 ON  
20110510_161003 ??? 9.4 -2147483648 -2147483648 -1.00 -1.00 110422 1 400 990 0.4 0.4 3 107 ON 80.9 H 70 214 ON  
20110510_161204 ??? 9.5 -2147483648 -2147483648 -1.00 -1.00 110422 1 400 990 0.4 0.4 3 99 ON 82.6 H 70 214 ON  
20110510_161259 ??? 9.4 -2147483648 -2147483648 -1.00 -1.00 110422 1 400 990 0.4 0.4 3 106 ON 77.9 H 70 214 ON  
20110510_161354 ??? 9.4 -2147483648 -2147483648 -1.00 -1.00 110422 1 400 990 0.4 0.4 3 108 ON 79.1 H 70 214 ON  

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR band exp #frames disturb notes
20110510_162318 ??? 10.5 -2147483648 -2147483648 -1.00 -1.00 171951 2 153 991 0.4 0.6 3 156 ON 54.3 H 70 214 ON  
20110510_162411 ??? 10.5 -2147483648 -2147483648 -1.00 -1.00 171951 2 153 991 0.4 0.6 3 161 ON -1.0 ? -1 -1 ON  
20110510_162434 ??? 10.5 -2147483648 -2147483648 -1.00 -1.00 171951 2 153 991 0.4 0.6 3 160 ON 56.9 H 70 214 ON  
20110510_162634 ??? 10.5 -2147483648 -2147483648 -1.00 -1.00 171951 2 153 991 0.4 0.6 3 155 ON 60.4 H 70 214 ON  
20110510_162727 ??? 10.5 -2147483648 -2147483648 -1.00 -1.00 171951 2 153 991 0.4 0.6 3 156 ON 60.8 H 70 214 ON  
20110510_162821 ??? 10.5 -2147483648 -2147483648 -1.00 -1.00 171951 2 153 991 0.4 0.6 3 162 ON 60.8 H 70 214 ON  

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR band exp #frames disturb notes
20110510_163238 ??? 11.5 -2147483648 -2147483648 -1.00 -1.00 171951 2 153 991 0.3 0.4 3 64 ON 59.7 H 100 150 ON  
20110510_163321 ??? 11.4 -2147483648 -2147483648 -1.00 -1.00 171951 2 153 991 0.3 0.4 3 69 ON 47.9 H 100 150 ON  
20110510_163403 ??? 11.4 -2147483648 -2147483648 -1.00 -1.00 171951 2 153 991 0.3 0.4 3 67 ON 52.5 H 100 150 ON  
20110510_163507 ??? 11.5 -2147483648 -2147483648 -1.00 -1.00 171951 2 153 991 0.3 0.4 3 64 ON 57.1 H 100 150 ON  
20110510_163550 ??? 11.4 -2147483648 -2147483648 -1.00 -1.00 171951 2 153 991 0.3 0.4 3 67 ON 57.0 H 100 150 ON  
20110510_163632 ??? 11.4 -2147483648 -2147483648 -1.00 -1.00 171951 2 153 991 0.3 0.4 3 67 ON 56.6 H 100 150 ON  

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR band exp #frames disturb notes
20110510_164318 ??? 11.4 -2147483648 -2147483648 -1.00 -1.00 171951 2 153 991 0.3 0.6 3 71 ON 58.1 H 100 150 ON  
20110510_164401 ??? 11.4 -2147483648 -2147483648 -1.00 -1.00 171951 2 153 991 0.3 0.6 3 69 ON 61.3 H 100 150 ON  
20110510_164443 ??? 11.4 -2147483648 -2147483648 -1.00 -1.00 171951 2 153 991 0.3 0.6 3 66 ON -1.0 ? -1 -1 ON  
20110510_164602 ??? 11.5 -2147483648 -2147483648 -1.00 -1.00 171951 2 153 991 0.3 0.6 3 63 ON 44.5 H 100 150 ON  
20110510_164644 ??? 11.4 -2147483648 -2147483648 -1.00 -1.00 171951 2 153 991 0.3 0.6 3 66 ON 57.9 H 100 150 ON  
20110510_164727 ??? 11.4 -2147483648 -2147483648 -1.00 -1.00 171951 2 153 991 0.3 0.6 3 66 ON 52.7 H 100 150 ON  

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR band exp #frames disturb notes
20110510_171924 ??? 12.4 -2147483648 -2147483648 -1.00 -1.00 154434 2 120 625 0.5 0.7 3 43 ON 49.5 H 150 100 ON  
20110510_171958 ??? 12.4 -2147483648 -2147483648 -1.00 -1.00 154434 2 120 625 0.5 0.7 3 44 ON 49.4 H 150 100 ON  
20110510_172032 ??? 12.4 -2147483648 -2147483648 -1.00 -1.00 154434 2 120 625 0.5 0.7 3 45 ON 36.7 H 150 100 ON  
20110510_172154 ??? 12.5 -2147483648 -2147483648 -1.00 -1.00 154434 2 120 625 0.5 0.7 3 38 ON 42.2 H 150 100 ON  
20110510_172228 ??? 12.5 -2147483648 -2147483648 -1.00 -1.00 154434 2 120 625 0.5 0.7 3 41 ON 44.2 H 150 100 ON  
20110510_172302 ??? 12.5 -2147483648 -2147483648 -1.00 -1.00 154434 2 120 625 0.5 0.7 3 41 ON 36.4 H 150 100 ON  

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR band exp #frames disturb notes
20110510_172738 ??? 13.5 -2147483648 -2147483648 -1.00 -1.00 171410 3 66 200 1.0 1.3 6 113 ON 25.6 H 100 150 ON  
20110510_172821 ??? 13.5 -2147483648 -2147483648 -1.00 -1.00 171410 3 66 200 1.0 1.3 6 114 ON 28.0 H 100 150 ON  
20110510_172903 ??? 13.5 -2147483648 -2147483648 -1.00 -1.00 171410 3 66 200 1.0 1.3 6 118 ON -1.0 ? -1 -1 ON  
20110510_173030 ??? 13.5 -2147483648 -2147483648 -1.00 -1.00 171410 3 66 200 1.0 1.3 6 112 ON 25.3 H 100 150 ON  
20110510_173113 ??? 13.5 -2147483648 -2147483648 -1.00 -1.00 171410 3 66 200 1.0 1.3 6 117 ON 26.1 H 100 150 ON  
20110510_173156 ??? 13.5 -2147483648 -2147483648 -1.00 -1.00 171410 3 66 200 1.0 1.3 6 115 ON 17.9 H 100 150 ON  

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR band exp #frames disturb notes
20110510_174914 ??? 14.5 -2147483648 -2147483648 -1.00 -1.00 152928 4 36 100 1.4 1.7 6 170 ON -1.0 ? -1 -1 ON  
20110510_175006 ??? 14.7 -2147483648 -2147483648 -1.00 -1.00 152928 4 36 100 1.4 1.7 6 141 ON 8.5 H 300 50 ON  
20110510_175058 ??? 14.7 -2147483648 -2147483648 -1.00 -1.00 152928 4 36 100 1.4 1.7 6 143 ON -1.0 ? -1 -1 ON  
20110510_175229 ??? 14.7 -2147483648 -2147483648 -1.00 -1.00 152928 4 36 100 1.4 1.7 6 139 ON 8.0 H 300 50 ON  
20110510_175320 ??? 14.7 -2147483648 -2147483648 -1.00 -1.00 152928 4 36 100 1.4 1.7 6 139 ON 7.6 H 300 50 ON  
20110510_175412 ??? 14.7 -2147483648 -2147483648 -1.00 -1.00 152928 4 36 100 1.4 1.7 6 143 ON 7.7 H 300 50 ON  

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR band exp #frames disturb notes
20110510_175910 ??? 15.5 -2147483648 -2147483648 -1.00 -1.00 152928 4 36 200 0.5 1.1 6 33 ON 8.0 H 400 37 ON  
20110510_175939 ??? 15.5 -2147483648 -2147483648 -1.00 -1.00 152928 4 36 200 0.5 1.1 6 34 ON 8.8 H 400 37 ON  
20110510_180008 ??? 15.5 -2147483648 -2147483648 -1.00 -1.00 152928 4 36 200 0.5 1.1 6 34 ON 7.8 H 400 37 ON  
20110510_180115 ??? 15.5 -2147483648 -2147483648 -1.00 -1.00 152928 4 36 200 0.5 1.1 6 32 ON 6.8 H 400 37 ON  
20110510_180145 ??? 15.6 -2147483648 -2147483648 -1.00 -1.00 152928 4 36 200 0.5 1.1 6 31 ON 7.2 H 400 37 ON  
20110510_180214 ??? 15.5 -2147483648 -2147483648 -1.00 -1.00 152928 4 36 200 0.5 1.1 6 34 ON 4.8 H 400 37 ON  

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR band exp #frames disturb notes
20110510_180902 ??? 16.5 -2147483648 -2147483648 -1.00 -1.00 152928 4 36 100 0.6 1.4 6 27 ON 2.7 H 400 37 ON  
20110510_180953 ??? 16.5 -2147483648 -2147483648 -1.00 -1.00 152928 4 36 100 0.6 1.4 6 26 ON 1.9 H 400 37 ON  
20110510_181043 ??? 16.5 -2147483648 -2147483648 -1.00 -1.00 152928 4 36 100 0.6 1.4 6 28 ON 2.1 H 400 37 ON  

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR band exp #frames disturb notes
20110510_182123 ??? 16.4 -2147483648 -2147483648 -1.00 -1.00 152928 4 36 100 0.7 1.1 6 31 ON 3.2 H 400 37 ON  
20110510_182214 ??? 16.4 -2147483648 -2147483648 -1.00 -1.00 152928 4 36 100 0.7 1.1 6 29 ON 3.0 H 400 37 ON  
20110510_182304 ??? 16.4 -2147483648 -2147483648 -1.00 -1.00 152928 4 36 100 0.7 1.1 6 29 ON 3.0 H 400 37 ON  
20110510_182433 ??? 16.4 -2147483648 -2147483648 -1.00 -1.00 152928 4 36 100 0.7 1.1 6 28 ON 2.8 H 400 37 ON  
20110510_182523 ??? 16.4 -2147483648 -2147483648 -1.00 -1.00 152928 4 36 100 0.7 1.1 6 29 ON 2.7 H 400 37 ON - SR may be in error
20110510_182614 ??? 16.3 -2147483648 -2147483648 -1.00 -1.00 152928 4 36 100 0.7 1.1 6 31 ON 2.8 H 400 37 ON - SR may be in error

bin1_mag8_5 = ['20110510_132804','20110510_132915','20110510_133026','20110510_133257','20110510_133408','20110510_133519']
bin1_mag8_5_take2 =  ['20110510_155444','20110510_155554','20110510_155704','20110510_155933','20110510_160043','20110510_160154']
bin1_mag9_5 = ['20110510_134025','20110510_134120','20110510_134214','20110510_134416','20110510_134447','20110510_134542']
bin1_mag9_5_take2 = ['20110510_160839','20110510_160934','20110510_161003','20110510_161204','20110510_161259','20110510_161354']

flao2_bin1 = obj_new('aodataset',[bin1_mag8_5, bin1_mag8_5_take2, bin1_mag9_5, bin1_mag9_5_take2])
sr_b1 = flao2_bin1->value('irtc.sr_se')
mag_b1 = flao2_bin1->value('mag')

bin2_mag10_5 =  ['20110510_162318','20110510_162411','20110510_162434','20110510_162634','20110510_162727','20110510_162821']
bin2_mag11_5 = ['20110510_144034','20110510_144117','20110510_144159','20110510_144318','20110510_144401','20110510_144443']
bin2_mag11_5_take2 = ['20110510_163238','20110510_163321','20110510_163403','20110510_163507','20110510_163550','20110510_163632']
bin2_mag11_5_take3  =  ['20110510_164318','20110510_164401','20110510_164443','20110510_164602','20110510_164644','20110510_164727']
bin2_mag12_5 =  ['20110510_171924','20110510_171958','20110510_172032','20110510_172154','20110510_172228','20110510_172302']
flao2_bin2 = obj_new('aodataset',[bin2_mag10_5, bin2_mag11_5, bin2_mag11_5_take2, bin2_mag11_5_take3, bin2_mag12_5])
sr_b2 = flao2_bin2->value('irtc.sr_se')
mag_b2 = flao2_bin2->value('mag')

bin3_mag13_5 = ['20110510_145632','20110510_145702','20110510_145731','20110510_145910','20110510_145952','20110510_150035']
bin3_mag13_5_take2 =  ['20110510_172738','20110510_172821','20110510_172903','20110510_173030','20110510_173113','20110510_173156']

bin3_mag14_5 =  ['20110510_150448','20110510_150519','20110510_150549','20110510_150700','20110510_150730','20110510_150800']
flao2_bin3=obj_new('aodataset',[bin3_mag13_5, bin3_mag13_5_take2, bin3_mag14_5])
sr_b3 = flao2_bin3->value('irtc.sr_se')
mag_b3 = flao2_bin3->value('mag')

bin4_mag14_5 =  ['20110510_174914','20110510_175006','20110510_175058','20110510_175229','20110510_175320','20110510_175412']
bin4_mag15_5 = ['20110510_175910','20110510_175939','20110510_180008','20110510_180115','20110510_180145','20110510_180214']
bin4_mag16_5 = ['20110510_180902','20110510_180953','20110510_181043']
bin4_mag16_5_take2 =  ['20110510_182123','20110510_182214','20110510_182304','20110510_182433','20110510_182523','20110510_182614']
flao2_bin4=obj_new('aodataset',[bin4_mag14_5, bin4_mag15_5, bin4_mag16_5, bin4_mag16_5_take2])
sr_b4 = flao2_bin4->value('irtc.sr_se')
mag_b4 = flao2_bin4->value('mag')


; Simulation data (baseline and goal)
simul_table=fltarr(9,3)
simul_table[*,0]=[8.5,9.5,10.5,11.5,12.5,13.5,14.5,15.5,16.5]
simul_table[*,1]=[0.62,0.59,0.50,0.48,0.42,0.27,0.19,0.071,0.026]
simul_table[*,2]=[0.80,0.77,0.62,0.59,0.54,0.37,0.27,0.12,0.052]

plot, simul_table[*,0], simul_table[*,2], title='SR FLAO#2 @ tower testbench in April 2011', xtitle='R+I mag',ytitle='SR value (H band)', charsize=2, yrange=[0,1]
oplot, simul_table[*,0], simul_table[*,2],col='00ff00'x
oplot, simul_table[*,0], simul_table[*,1],col='0000ff'x
oplot, mag_b1, sr_b1, psym=4
oplot, mag_b2, sr_b2, psym=6
oplot, mag_b3, sr_b3, psym=5 
oplot, mag_b4, sr_b4, psym=2 

  • SR_may10.png:
    SR_may10.png
Topic revision: r1 - 10 May 2011, AlfioPuglisi
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding Foswiki? Send feedback