Offload test

Serie 1

Offload on; Seeing 0.8"

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR band exp #frames disturb notes
20110509_150356 ??? 7.7 -2147483648 -2147483648 -1.00 -1.00 110422 1 400 990 0.4 0.4 3 507 ON 52.4 H 50 200 ON  
20110509_150444 ??? 7.7 -2147483648 -2147483648 -1.00 -1.00 110422 1 400 990 0.4 0.4 3 500 ON 84.6 H 50 200 ON  
20110509_150532 ??? 7.7 -2147483648 -2147483648 -1.00 -1.00 110422 1 400 990 0.4 0.4 3 500 ON 84.5 H 50 200 ON  
20110509_150714 ??? 7.8 -2147483648 -2147483648 -1.00 -1.00 110422 1 400 990 0.4 0.4 3 485 ON 76.3 H 50 200 ON  
20110509_150802 ??? 7.7 -2147483648 -2147483648 -1.00 -1.00 110422 1 400 990 0.4 0.4 3 499 ON 71.6 H 50 200 ON  
20110509_150849 ??? 7.7 -2147483648 -2147483648 -1.00 -1.00 110422 1 400 990 0.4 0.4 3 501 ON 81.2 H 50 200 ON  

Offload off; Seeing 0.8"

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR band exp #frames disturb notes
20110509_151012 ??? 7.7 -2147483648 -2147483648 -1.00 -1.00 110422 1 400 990 0.4 0.4 3 500 ON 85.4 H 50 200 ON  
20110509_151100 ??? 7.7 -2147483648 -2147483648 -1.00 -1.00 110422 1 400 990 0.4 0.4 3 500 ON 81.1 H 50 200 ON  
20110509_151147 ??? 7.7 -2147483648 -2147483648 -1.00 -1.00 110422 1 400 990 0.4 0.4 3 499 ON 86.4 H 50 200 ON  
20110509_151329 ??? 7.8 -2147483648 -2147483648 -1.00 -1.00 110422 1 400 990 0.4 0.4 3 487 ON 84.4 H 50 200 ON  
20110509_151417 ??? 7.7 -2147483648 -2147483648 -1.00 -1.00 110422 1 400 990 0.4 0.4 3 500 ON 85.2 H 50 200 ON  
20110509_151505 ??? 7.7 -2147483648 -2147483648 -1.00 -1.00 110422 1 400 990 0.4 0.4 3 503 ON 85.8 H 50 200 ON  

Serie 2

Offload on; Seeing 0.8"

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR band exp #frames disturb notes
20110509_151722 ??? 7.7 -2147483648 -2147483648 -1.00 -1.00 110422 1 400 990 0.4 0.4 3 502 ON 87.3 H 50 200 ON  
20110509_151810 ??? 7.7 -2147483648 -2147483648 -1.00 -1.00 110422 1 400 990 0.4 0.4 3 502 ON 86.7 H 50 200 ON  
20110509_151858 ??? 7.7 -2147483648 -2147483648 -1.00 -1.00 110422 1 400 990 0.4 0.4 3 500 ON 85.8 H 50 200 ON  
20110509_152040 ??? 7.8 -2147483648 -2147483648 -1.00 -1.00 110422 1 400 990 0.4 0.4 3 490 ON 86.1 H 50 200 ON  
20110509_152127 ??? 7.7 -2147483648 -2147483648 -1.00 -1.00 110422 1 400 990 0.4 0.4 3 501 ON 86.8 H 50 200 ON  
20110509_152215 ??? 7.7 -2147483648 -2147483648 -1.00 -1.00 110422 1 400 990 0.4 0.4 3 502 ON 85.3 H 50 200 ON  

Offload off; Seeing 0.8"

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR band exp #frames disturb notes
20110509_152321 ??? 7.7 -2147483648 -2147483648 -1.00 -1.00 110422 1 400 990 0.4 0.4 3 505 ON 85.2 H 50 200 ON - long stop of 54 frames at frame 2995
20110509_152408 ??? 7.7 -2147483648 -2147483648 -1.00 -1.00 110422 1 400 990 0.4 0.4 3 501 ON 83.6 H 50 200 ON  
20110509_152456 ??? 7.7 -2147483648 -2147483648 -1.00 -1.00 110422 1 400 990 0.4 0.4 3 504 ON 83.9 H 50 200 ON  
20110509_152638 ??? 7.8 -2147483648 -2147483648 -1.00 -1.00 110422 1 400 990 0.4 0.4 3 489 ON 83.5 H 50 200 ON  
20110509_152728 ??? 7.7 -2147483648 -2147483648 -1.00 -1.00 110422 1 400 990 0.4 0.4 3 501 ON 76.4 H 50 200 ON  
20110509_152817 ??? 7.7 -2147483648 -2147483648 -1.00 -1.00 110422 1 400 990 0.4 0.4 3 502 ON 86.9 H 50 200 ON  

Serie 3

Offload on; Seeing 0.8"

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR band exp #frames disturb notes
20110509_152925 ??? 7.7 -2147483648 -2147483648 -1.00 -1.00 110422 1 400 990 0.4 0.4 3 504 ON 86.2 H 50 200 ON  
20110509_153013 ??? 7.7 -2147483648 -2147483648 -1.00 -1.00 110422 1 400 990 0.4 0.4 3 503 ON 80.7 H 50 200 ON  
20110509_153100 ??? 7.7 -2147483648 -2147483648 -1.00 -1.00 110422 1 400 990 0.4 0.4 3 502 ON 83.8 H 50 200 ON  
20110509_153242 ??? 7.8 -2147483648 -2147483648 -1.00 -1.00 110422 1 400 990 0.4 0.4 3 486 ON 60.9 H 50 200 ON  
20110509_153333 ??? 7.7 -2147483648 -2147483648 -1.00 -1.00 110422 1 400 990 0.4 0.4 3 506 ON 82.6 H 50 200 ON  
20110509_153421 ??? 7.7 -2147483648 -2147483648 -1.00 -1.00 110422 1 400 990 0.4 0.4 3 504 ON 86.4 H 50 200 ON  

Offload off; Seeing 0.8"

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR band exp #frames disturb notes
20110509_153519 ??? 7.7 -2147483648 -2147483648 -1.00 -1.00 110422 1 400 990 0.4 0.4 3 501 ON 75.8 H 50 200 ON  
20110509_153606 ??? 7.7 -2147483648 -2147483648 -1.00 -1.00 110422 1 400 990 0.4 0.4 3 504 ON 29.7 H 50 200 ON  
20110509_153654 ??? 7.7 -2147483648 -2147483648 -1.00 -1.00 110422 1 400 990 0.4 0.4 3 503 ON 63.0 H 50 200 ON  
20110509_153836 ??? 7.8 -2147483648 -2147483648 -1.00 -1.00 110422 1 400 990 0.4 0.4 3 489 ON 85.8 H 50 200 ON  
20110509_153924 ??? 7.7 -2147483648 -2147483648 -1.00 -1.00 110422 1 400 990 0.4 0.4 3 504 ON 85.4 H 50 200 ON  
20110509_154013 ??? 7.7 -2147483648 -2147483648 -1.00 -1.00 110422 1 400 990 0.4 0.4 3 502 ON 72.4 H 50 200 ON  
  • tip_spectrum.png:
    tip_spectrum.png

Measuring during Offload; Seeing 0.8"

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR band exp #frames disturb notes
20110509_155018 ??? 7.7 -2147483648 -2147483648 -1.00 -1.00 110422 1 400 990 0.4 0.4 3 505 ON 85.8 H 50 200 ON  
20110509_155127 ??? 7.7 -2147483648 -2147483648 -1.00 -1.00 110422 1 400 990 0.4 0.4 3 502 ON 85.6 H 50 200 ON  
20110509_155257 ??? 7.7 -2147483648 -2147483648 -1.00 -1.00 110422 1 400 990 0.4 0.4 3 502 ON 85.4 H 50 200 ON  

offload_on1= ['20110509_150356','20110509_150444','20110509_150532','20110509_150714','20110509_150802','20110509_150849']
offload_on2= ['20110509_151722','20110509_151810','20110509_151858','20110509_152040','20110509_152127','20110509_152215']
offload_on3= ['20110509_152925','20110509_153013','20110509_153100','20110509_153242','20110509_153333','20110509_153421']
offload_off1= ['20110509_151012','20110509_151100','20110509_151147','20110509_151329','20110509_151417','20110509_151505']
offload_off2=['20110509_152321','20110509_152408','20110509_152456','20110509_152638','20110509_152728','20110509_152817']
offload_off3=['20110509_153519','20110509_153606','20110509_153654','20110509_153836','20110509_153924','20110509_154013']

offload_on = obj_new('aodataset',[offload_on1,offload_on2,offload_on3])
sr_offloadon = offload_on->value('irtc.sr_se')
mag_offloadon = offload_on->value('mag')

offload_off = obj_new('aodataset',[offload_off1,offload_off2,offload_off3])
sr_offloadoff = offload_off->value('irtc.sr_se')
mag_offloadoff = offload_off->value('mag')

plot, mag_offloadon, sr_offloadon, psym=4, title='SR FLAO#2 @ tower testbench in April 2011', xtitle='R+I mag',ytitle='SR value (H band)', charsize=2, xrange=[7.5,8.0], yrange=[0,1]
oplot, mag_offloadon, sr_offloadon, psym=4, col='00ff00'x
oplot, mag_offloadoff, sr_offloadoff, psym=6, col='0000ff'x

 hist_off=histogram(sr_offloadoff,binsize=0.05, locations=srval)

hist_on=histogram(sr_offloadon,binsize=0.05, locations=srvalon)
plot, srvalon,hist_on, psym=10
oplot, srvaloff,hist_off, psym=10, col='0000ff'x
oplot, srvalon,hist_on, psym=10, col='00ff00'x

-- RunaBriguglio - 09 May 2011