UPS

Partenza lenta perché in torre era saltata la corrente e tutto ha dovuto ripartire da zero. Abbiamo messo un UPS su wfssx e allo switch perché rimanga acceso in questi casi (su adsecsx c'è già).

Modifiche AntiDrift

Modificata la procedura di antdrift: adesso è sempre acceso a partire dal preset. Viene disattivato durante l'acquisizione del dark del ccd39 e durante il change binning.

Modifiche tabella AO intorno a 14.5

Modificata la tabella AO in modo che lo scambio bin3 -> bin4 sia a mag. 14.8, in questo modo si recupera qualcosa a bin3.

Mag 8.5

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR band exp #frames disturb notes
20110505_103457 ??? 8.5 -2147483648 -2147483648 -1.00 -1.00 110422 1 400 990 0.4 0.5 3 255 ON 83.1 H 50 300 ON  
20110505_103727 ??? 8.5 -2147483648 -2147483648 -1.00 -1.00 110422 1 400 990 0.4 0.5 3 243 ON 83.2 H 50 300 ON  
20110505_103837 ??? 8.5 -2147483648 -2147483648 -1.00 -1.00 110422 1 400 990 0.4 0.5 3 257 ON 82.9 H 50 300 ON  
20110505_103948 ??? 8.5 -2147483648 -2147483648 -1.00 -1.00 110422 1 400 990 0.4 0.5 3 258 ON 82.9 H 50 300 ON  

Mag 14.7

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR band exp #frames disturb notes
20110505_115609 ??? 14.6 -2147483648 -2147483648 -1.00 -1.00 171410 3 66 200 0.6 0.7 6 43 ON 31.8 H 300 50 ON - SR may be in error
20110505_115640 ??? 14.6 -2147483648 -2147483648 -1.00 -1.00 171410 3 66 200 0.6 0.7 6 40 ON 34.1 H 300 50 ON - SR may be in error
20110505_115710 ??? 14.8 -2147483648 -2147483648 -1.00 -1.00 171410 3 66 200 0.6 0.7 6 36 ON 36.5 H 300 50 ON - SR may be in error
20110505_115801 ??? 14.7 -2147483648 -2147483648 -1.00 -1.00 171410 3 66 200 0.6 0.7 6 38 ON 21.7 H 300 50 ON  

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR band exp #frames disturb notes
20110505_120249 ??? 14.7 -2147483648 -2147483648 -1.00 -1.00 171410 3 66 200 0.5 0.7 6 36 ON 20.0 H 300 50 ON  
20110505_120318 ??? 14.7 -2147483648 -2147483648 -1.00 -1.00 171410 3 66 200 0.5 0.7 6 39 ON 19.7 H 300 50 ON  
20110505_120348 ??? 14.6 -2147483648 -2147483648 -1.00 -1.00 171410 3 66 200 0.5 0.7 6 40 ON 19.6 H 300 50 ON  
20110505_120458 ??? 14.7 -2147483648 -2147483648 -1.00 -1.00 171410 3 66 200 0.5 0.7 6 38 ON 20.1 H 300 50 ON  
20110505_120527 ??? 14.7 -2147483648 -2147483648 -1.00 -1.00 171410 3 66 200 0.5 0.7 6 38 ON 20.3 H 300 50 ON  
20110505_120557 ??? 14.7 -2147483648 -2147483648 -1.00 -1.00 171410 3 66 200 0.5 0.7 6 38 ON 20.7 H 300 50 ON  

Tabella

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR band exp #frames disturb notes
20110505_122318 ??? 8.5 -2147483648 -2147483648 -1.00 -1.00 110422 1 400 990 0.3 0.4 3 256 ON 78.7 H 50 300 ON  
20110505_122431 ??? 8.4 -2147483648 -2147483648 -1.00 -1.00 110422 1 400 990 0.3 0.4 3 262 ON 80.3 H 50 300 ON  
20110505_122545 ??? 8.4 -2147483648 -2147483648 -1.00 -1.00 110422 1 400 990 0.3 0.4 3 262 ON -1.0 ? -1 -1 ON  
20110505_122740 ??? 8.5 -2147483648 -2147483648 -1.00 -1.00 110422 1 400 990 0.3 0.4 3 248 ON 83.9 H 50 300 ON  
20110505_122854 ??? 8.5 -2147483648 -2147483648 -1.00 -1.00 110422 1 400 990 0.3 0.4 3 259 ON 84.5 H 50 300 ON  
20110505_123008 ??? 8.5 -2147483648 -2147483648 -1.00 -1.00 110422 1 400 990 0.3 0.4 3 260 ON 85.8 H 50 300 ON  

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR band exp #frames disturb notes
20110505_123502 ??? 9.5 -2147483648 -2147483648 -1.00 -1.00 110422 1 400 990 0.3 0.4 3 101 ON 78.2 H 70 214 ON  
20110505_123556 ??? 9.5 -2147483648 -2147483648 -1.00 -1.00 110422 1 400 990 0.3 0.4 3 103 ON -1.0 ? -1 -1 ON  
20110505_123625 ??? 9.5 -2147483648 -2147483648 -1.00 -1.00 110422 1 400 990 0.3 0.4 3 102 ON 79.9 H 70 214 ON  
20110505_123826 ??? 9.6 -2147483648 -2147483648 -1.00 -1.00 110422 1 400 990 0.3 0.4 3 93 ON -1.0 ? -1 -1 ON  
20110505_123854 ??? 9.5 -2147483648 -2147483648 -1.00 -1.00 110422 1 400 990 0.3 0.4 3 97 ON 83.3 H 70 214 ON  
20110505_123949 ??? 9.5 -2147483648 -2147483648 -1.00 -1.00 110422 1 400 990 0.3 0.4 3 102 ON 84.1 H 70 214 ON  

20110505_124419 ??? 10.5 -2147483648 -2147483648 -1.00 -1.00 151551 1 300 990 0.3 0.4 3 40 ON 68.1 H 70 214 ON  
20110505_124513 ??? 10.4 -2147483648 -2147483648 -1.00 -1.00 151551 1 300 990 0.3 0.4 3 43 ON 69.0 H 70 214 ON  
20110505_124608 ??? 10.4 -2147483648 -2147483648 -1.00 -1.00 151551 1 300 990 0.3 0.4 3 43 ON -1.0 ? -1 -1 ON  
20110505_124743 ??? 10.4 -2147483648 -2147483648 -1.00 -1.00 151551 1 300 990 0.3 0.4 3 42 ON 68.8 H 70 214 ON  
20110505_124838 ??? 10.4 -2147483648 -2147483648 -1.00 -1.00 151551 1 300 990 0.3 0.4 3 44 ON 69.7 H 70 214 ON  
20110505_124932 ??? 10.4 -2147483648 -2147483648 -1.00 -1.00 151551 1 300 990 0.3 0.4 3 41 ON 69.9 H 70 214 ON  

20110505_125408 ??? 11.6 -2147483648 -2147483648 -1.00 -1.00 171951 2 153 991 0.3 0.4 3 59 ON -1.0 ? -1 -1 ON  
20110505_125430 ??? 11.5 -2147483648 -2147483648 -1.00 -1.00 171951 2 153 991 0.3 0.4 3 65 ON 60.1 H 100 150 ON  
20110505_125513 ??? 11.5 -2147483648 -2147483648 -1.00 -1.00 171951 2 153 991 0.3 0.4 3 62 ON 59.7 H 100 150 ON  
20110505_125651 ??? 11.5 -2147483648 -2147483648 -1.00 -1.00 171951 2 153 991 0.3 0.4 3 60 ON 60.4 H 100 150 ON  
20110505_125734 ??? 11.5 -2147483648 -2147483648 -1.00 -1.00 171951 2 153 991 0.3 0.4 3 62 ON 61.4 H 100 150 ON  
20110505_125817 ??? 11.5 -2147483648 -2147483648 -1.00 -1.00 171951 2 153 991 0.3 0.4 3 62 ON 61.5 H 100 150 ON  

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR band exp #frames disturb notes
20110505_130218 ??? 12.4 -2147483648 -2147483648 -1.00 -1.00 154434 2 120 625 0.5 0.5 3 43 ON 48.5 H 150 100 ON  
20110505_130252 ??? 12.4 -2147483648 -2147483648 -1.00 -1.00 154434 2 120 625 0.5 0.5 3 43 ON 49.8 H 150 100 ON  
20110505_130326 ??? 12.5 -2147483648 -2147483648 -1.00 -1.00 154434 2 120 625 0.5 0.5 3 41 ON 50.6 H 150 100 ON  
20110505_130449 ??? 12.6 -2147483648 -2147483648 -1.00 -1.00 154434 2 120 625 0.5 0.5 3 36 ON 47.9 H 150 100 ON  
20110505_130523 ??? 12.5 -2147483648 -2147483648 -1.00 -1.00 154434 2 120 625 0.5 0.5 3 41 ON 48.6 H 150 100 ON  
20110505_130557 ??? 12.5 -2147483648 -2147483648 -1.00 -1.00 154434 2 120 625 0.5 0.5 3 40 ON 51.0 H 150 100 ON  

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR band exp #frames disturb notes
20110505_131026 ??? 13.6 -2147483648 -2147483648 -1.00 -1.00 171410 3 66 200 1.1 1.2 6 109 ON 31.3 H 100 150 ON  
20110505_131108 ??? 13.5 -2147483648 -2147483648 -1.00 -1.00 171410 3 66 200 1.1 1.2 6 113 ON 31.7 H 100 150 ON  
20110505_131151 ??? 13.6 -2147483648 -2147483648 -1.00 -1.00 171410 3 66 200 1.1 1.2 6 109 ON 31.1 H 100 150 ON  
20110505_131329 ??? 13.6 -2147483648 -2147483648 -1.00 -1.00 171410 3 66 200 1.1 1.2 6 105 ON 30.0 H 100 150 ON  
20110505_131412 ??? 13.6 -2147483648 -2147483648 -1.00 -1.00 171410 3 66 200 1.1 1.2 6 109 ON 31.2 H 100 150 ON  
20110505_131455 ??? 13.5 -2147483648 -2147483648 -1.00 -1.00 171410 3 66 200 1.1 1.2 6 110 ON 31.2 H 100 150 ON  

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR band exp #frames disturb notes
20110505_131903 ??? 14.7 -2147483648 -2147483648 -1.00 -1.00 171410 3 66 200 0.7 0.9 6 38 ON 17.5 H 300 50 ON  
20110505_131933 ??? 14.6 -2147483648 -2147483648 -1.00 -1.00 171410 3 66 200 0.7 0.9 6 42 ON 17.9 H 300 50 ON  
20110505_132002 ??? 14.7 -2147483648 -2147483648 -1.00 -1.00 171410 3 66 200 0.7 0.9 6 40 ON 18.0 H 300 50 ON  
20110505_132112 ??? 14.7 -2147483648 -2147483648 -1.00 -1.00 171410 3 66 200 0.7 0.9 6 37 ON 17.4 H 300 50 ON  
20110505_132141 ??? 14.6 -2147483648 -2147483648 -1.00 -1.00 171410 3 66 200 0.7 0.9 6 42 ON -1.0 ? -1 -1 ON  
20110505_132210 ??? 14.6 -2147483648 -2147483648 -1.00 -1.00 171410 3 66 200 0.7 0.9 6 42 ON 18.4 H 300 50 ON  

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR band exp #frames disturb notes
20110505_132712 ??? 15.6 -2147483648 -2147483648 -1.00 -1.00 152928 4 36 200 0.7 1.0 6 31 ON 8.2 H 400 37 ON  
20110505_132741 ??? 15.5 -2147483648 -2147483648 -1.00 -1.00 152928 4 36 200 0.7 1.0 6 35 ON 8.7 H 400 37 ON  
20110505_132810 ??? 15.5 -2147483648 -2147483648 -1.00 -1.00 152928 4 36 200 0.7 1.0 6 35 ON -1.0 ? -1 -1 ON  
20110505_132917 ??? 15.5 -2147483648 -2147483648 -1.00 -1.00 152928 4 36 200 0.7 1.0 6 34 ON 8.2 H 400 37 ON  
20110505_132946 ??? 15.5 -2147483648 -2147483648 -1.00 -1.00 152928 4 36 200 0.7 1.0 6 35 ON 8.6 H 400 37 ON  
20110505_133015 ??? 15.5 -2147483648 -2147483648 -1.00 -1.00 152928 4 36 200 0.7 1.0 6 34 ON 8.6 H 400 37 ON  
Lo script si ferma alla magnitudine 16.5 durante l'autogain a causa di uno skip frame. Proviamo a ripetere il punto, ma durante la seconda psf lo specchio si rippa.

Disturbo sinousidale

Facciamo delle acquisizioni usando il disturbo con sommata la sinusoide

LA CAMERA E' SATURATA A CAUSA DELLA TEMPERATURA TROPPO ALTA quindi gli Sthrel sono sbagliati.

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR band exp #frames disturb notes
20110505_145003 ??? 8.4 -2147483648 -2147483648 -1.00 -1.00 110422 1 400 990 0.4 0.4 3 261 ON -1.0 ? -1 -1 ON - M2C is not the same as the M2C used in vibration disturb
20110505_145035 ??? 8.4 -2147483648 -2147483648 -1.00 -1.00 110422 1 400 990 0.4 0.4 3 263 ON 83.8 H 50 300 ON - M2C is not the same as the M2C used in vibration disturb
20110505_145305 ??? 8.5 -2147483648 -2147483648 -1.00 -1.00 110422 1 400 990 0.4 0.4 3 254 ON 84.1 H 50 300 ON - M2C is not the same as the M2C used in vibration disturb
20110505_145416 ??? 8.4 -2147483648 -2147483648 -1.00 -1.00 110422 1 400 990 0.4 0.4 3 262 ON 83.8 H 50 300 ON - M2C is not the same as the M2C used in vibration disturb
20110505_145527 ??? 8.4 -2147483648 -2147483648 -1.00 -1.00 110422 1 400 990 0.4 0.4 3 261 ON 83.9 H 50 300 ON - M2C is not the same as the M2C used in vibration disturb

20110505_150553 ??? 10.4 -2147483648 -2147483648 -1.00 -1.00 151551 1 300 990 0.3 0.4 3 42 ON 67.9 H 70 214 ON - M2C is not the same as the M2C used in vibration disturb
20110505_150647 ??? 10.5 -2147483648 -2147483648 -1.00 -1.00 151551 1 300 990 0.3 0.4 3 39 ON -1.0 ? -1 -1 ON - M2C is not the same as the M2C used in vibration disturb
20110505_150718 ??? 10.5 -2147483648 -2147483648 -1.00 -1.00 151551 1 300 990 0.3 0.4 3 40 ON 66.9 H 70 214 ON - M2C is not the same as the M2C used in vibration disturb
20110505_150918 ??? 10.6 -2147483648 -2147483648 -1.00 -1.00 151551 1 300 990 0.3 0.4 3 37 ON -1.0 ? -1 -1 ON - M2C is not the same as the M2C used in vibration disturb
20110505_150949 ??? 10.6 -2147483648 -2147483648 -1.00 -1.00 151551 1 300 990 0.3 0.4 3 37 ON 63.0 H 70 214 ON - M2C is not the same as the M2C used in vibration disturb
20110505_151044 ??? 10.5 -2147483648 -2147483648 -1.00 -1.00 151551 1 300 990 0.3 0.4 3 40 ON 55.9 H 70 214 ON - M2C is not the same as the M2C used in vibration disturb

20110505_151712 ??? 12.7 -2147483648 -2147483648 -1.00 -1.00 154434 2 120 801 0.2 0.3 3 27 ON 84.4 H 150 100 ON - long stop of 53 frames at frame 459 - M2C is not the same as the M2C used in vibration disturb
20110505_151746 ??? 12.5 -2147483648 -2147483648 -1.00 -1.00 154434 2 120 801 0.2 0.3 3 32 ON 84.8 H 150 100 ON - M2C is not the same as the M2C used in vibration disturb
20110505_151820 ??? 12.6 -2147483648 -2147483648 -1.00 -1.00 154434 2 120 801 0.2 0.3 3 28 ON 84.6 H 150 100 ON - M2C is not the same as the M2C used in vibration disturb
20110505_151942 ??? 12.7 -2147483648 -2147483648 -1.00 -1.00 154434 2 120 801 0.2 0.3 3 25 ON 80.8 H 150 100 ON - M2C is not the same as the M2C used in vibration disturb
20110505_152016 ??? 12.6 -2147483648 -2147483648 -1.00 -1.00 154434 2 120 801 0.2 0.3 3 27 ON 78.9 H 150 100 ON - M2C is not the same as the M2C used in vibration disturb
20110505_152050 ??? 12.6 -2147483648 -2147483648 -1.00 -1.00 154434 2 120 801 0.2 0.3 3 27 ON 82.7 H 150 100 ON - M2C is not the same as the M2C used in vibration disturb

20110505_152510 ??? 14.6 -2147483648 -2147483648 -1.00 -1.00 171410 3 66 200 0.3 0.3 6 41 ON 76.3 H 150 100 ON - M2C is not the same as the M2C used in vibration disturb
20110505_152545 ??? 14.6 -2147483648 -2147483648 -1.00 -1.00 171410 3 66 200 0.3 0.3 6 42 ON 78.9 H 150 100 ON - M2C is not the same as the M2C used in vibration disturb
20110505_152619 ??? 14.6 -2147483648 -2147483648 -1.00 -1.00 171410 3 66 200 0.3 0.3 6 41 ON 77.5 H 150 100 ON - M2C is not the same as the M2C used in vibration disturb
20110505_152741 ??? 14.6 -2147483648 -2147483648 -1.00 -1.00 171410 3 66 200 0.3 0.3 6 41 ON 76.7 H 150 100 ON - M2C is not the same as the M2C used in vibration disturb
20110505_152815 ??? 14.6 -2147483648 -2147483648 -1.00 -1.00 171410 3 66 200 0.3 0.3 6 41 ON 78.1 H 150 100 ON - M2C is not the same as the M2C used in vibration disturb
20110505_152849 ??? 14.6 -2147483648 -2147483648 -1.00 -1.00 171410 3 66 200 0.3 0.3 6 42 ON 60.2 H 150 100 ON - M2C is not the same as the M2C used in vibration disturb

20110505_153344 ??? 15.5 -2147483648 -2147483648 -1.00 -1.00 152928 4 36 200 0.1 0.3 6 34 ON 56.3 H 400 37 ON - M2C is not the same as the M2C used in vibration disturb
20110505_153415 ??? 15.5 -2147483648 -2147483648 -1.00 -1.00 152928 4 36 200 0.1 0.3 6 35 ON 56.4 H 400 37 ON - M2C is not the same as the M2C used in vibration disturb
20110505_153446 ??? 15.4 -2147483648 -2147483648 -1.00 -1.00 152928 4 36 200 0.1 0.3 6 35 ON 55.5 H 400 37 ON - M2C is not the same as the M2C used in vibration disturb
20110505_153555 ??? 15.5 -2147483648 -2147483648 -1.00 -1.00 152928 4 36 200 0.1 0.3 6 34 ON 56.6 H 400 37 ON - M2C is not the same as the M2C used in vibration disturb
20110505_153626 ??? 15.5 -2147483648 -2147483648 -1.00 -1.00 152928 4 36 200 0.1 0.3 6 35 ON 55.6 H 400 37 ON - M2C is not the same as the M2C used in vibration disturb

IRTC cooling

La IRTC si è scaldata fino a 268K. Il motivo era un rubinetto chiuso sul ramo che raffredda la camera. Dopo aver aperto il rubinetto la temperatura è tornata a 250 K.

Low gain during offset

Adesso l'AOArbitrator riduce il gain a 0.1 quando viene eseguito un offsetXY o un offsetZ, rimettendo il gain corretto subito dopo

Magnitude display

Il visore ccd39 mostra la magnitudine stimata dai conteggi

acquisizioni sprecate

Buona parte delle acquisizioni tra 153700 e 171500 sono da buttare perché:
  1. la camera era rimasta in campo grande e senza filtro dopo il restart dovuto al problema del cooling
  2. la camera senza cooling faceva immagini che non aiutavano con lo sthrel
  3. il disturbo "con vibration" genera dei modalplot molto strani di cui non ci fidiamo.

RON test

Tutto acceso tranne CUBE e LAMP

Bin: 1 - Framerate 990 Hz (2500 kpix/sec) - RON (e-): 8.89 (estimated)
Bin: 2 - Framerate 990 Hz ( 800 kpix/sec) - RON (e-): 6.47 (estimated)
Bin: 2 - Framerate 625 Hz ( 380 kpix/sec) - RON (e-): 4.61 (estimated)
Bin: 2 - Framerate 400 Hz ( 380 kpix/sec) - RON (e-): 4.66 (estimated)
Bin: 3 - Framerate 200 Hz ( 380 kpix/sec) - RON (e-): 4.94 (estimated)
Bin: 4 - Framerate 300 Hz ( 335 kpix/sec) - RON (e-): 4.27 (estimated)
Bin: 4 - Framerate 200 Hz ( 335 kpix/sec) - RON (e-): 4.28 (estimated)
Bin: 4 - Framerate 105 Hz ( 335 kpix/sec) - RON (e-): 4.32 (estimated)

Ripetuto:

Bin: 1 - Framerate 990 Hz (2500 kpix/sec) - RON (e-): 8.77 (estimated)
Bin: 2 - Framerate 990 Hz ( 800 kpix/sec) - RON (e-): 6.32 (estimated)
Bin: 2 - Framerate 625 Hz ( 380 kpix/sec) - RON (e-): 4.06 (estimated)
Bin: 2 - Framerate 400 Hz ( 380 kpix/sec) - RON (e-): 4.06 (estimated)
Bin: 3 - Framerate 200 Hz ( 380 kpix/sec) - RON (e-): 4.17 (estimated)
Bin: 4 - Framerate 300 Hz ( 335 kpix/sec) - RON (e-): 4.31 (estimated)
Bin: 4 - Framerate 200 Hz ( 335 kpix/sec) - RON (e-): 4.36 (estimated)
Bin: 4 - Framerate 105 Hz ( 335 kpix/sec) - RON (e-): 4.38 (estimated)

bin1_mag8_5 = ['20110505_103457','20110505_103727','20110505_103837','20110505_103948','20110505_122318','20110505_122431','20110505_122740','20110505_122854','20110505_123008']
bin1_mag9_5 = ['20110505_123502','20110505_123625','20110505_123854','20110505_123949']
bin1_mag10_5 = ['20110505_124419','20110505_124513','20110505_124743','20110505_124838','20110505_124932']
flao2_bin1 = obj_new('aodataset',[bin1_mag8_5, bin1_mag9_5, bin1_mag10_5])
sr_b1 = flao2_bin1->value('irtc.sr_se')
mag_b1 = flao2_bin1->value('mag')

bin2_mag11_5 = ['20110505_125430','20110505_125513','20110505_125651','20110505_125734','20110505_125817']
bin2_mag12_5 =  ['20110505_130218','20110505_130252','20110505_130326','20110505_130449','20110505_130523','20110505_130557']
flao2_bin2 = obj_new('aodataset',[bin2_mag11_5, bin2_mag12_5])
sr_b2 = flao2_bin2->value('irtc.sr_se')
mag_b2 = flao2_bin2->value('mag')

bin3_mag13_5 = ['20110505_131026','20110505_131108','20110505_131151','20110505_131329','20110505_131412','20110505_131455']
bin3_mag14_5 = ['20110505_115801','20110505_120249','20110505_120318','20110505_120348','20110505_120458','20110505_120527','20110505_120557', '20110505_131903','20110505_131933','20110505_132002','20110505_132112','20110505_132210']
flao2_bin3=obj_new('aodataset',[bin3_mag14_5, bin3_mag13_5])
sr_b3 = flao2_bin3->value('irtc.sr_se')
mag_b3 = flao2_bin3->value('mag')

bin4_mag15_5 = ['20110505_132712','20110505_132741','20110505_132917','20110505_132946','20110505_133015']
flao2_bin4=obj_new('aodataset',[bin4_mag15_5])
sr_b4 = flao2_bin4->value('irtc.sr_se')
mag_b4 = flao2_bin4->value('mag')


; Simulation data (baseline and goal)
simul_table=fltarr(9,3)
simul_table[*,0]=[8.5,9.5,10.5,11.5,12.5,13.5,14.5,15.5,16.5]
simul_table[*,1]=[0.62,0.59,0.50,0.48,0.42,0.27,0.19,0.071,0.026]
simul_table[*,2]=[0.80,0.77,0.62,0.59,0.54,0.37,0.27,0.12,0.052]

plot, simul_table[*,0], simul_table[*,2], title='SR FLAO#2 @ tower testbench in April 2011', xtitle='R+I mag',ytitle='SR value (H band)', charsize=2, yrange=[0,1]
oplot, simul_table[*,0], simul_table[*,2],col='00ff00'x
oplot, simul_table[*,0], simul_table[*,1],col='0000ff'x
oplot, mag_b1, sr_b1, psym=4
oplot, mag_b2, sr_b2, psym=6
oplot, mag_b3, sr_b3, psym=5 
oplot, mag_b4, sr_b4, psym=2 

-- AlfioPuglisi - 05 May 2011
Topic revision: r3 - 05 May 2011, AlfioPuglisi
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.