TrackNo |
RefStar |
Mag |
El |
Wind |
DIMM/OL |
Rec |
bin |
#mod |
freq |
gain |
mod |
nph |
AntiDrift |
SR |
band |
exp |
#frames |
disturb |
notes |
20110427_112938 |
??? |
15.5 |
-2147483648 |
-2147483648 |
-1.00 -1.00 |
152928 |
4 |
36 |
209 |
0.7 1.0 |
6 |
33 |
ON |
12.9 |
H |
400 |
37 |
ON |
- oversampling freq not a multiple of loop freq - SR may be in error |
20110427_113016 |
??? |
15.5 |
-2147483648 |
-2147483648 |
-1.00 -1.00 |
152928 |
4 |
36 |
209 |
0.7 1.0 |
6 |
32 |
ON |
8.0 |
H |
400 |
37 |
ON |
- oversampling freq not a multiple of loop freq |
20110427_113053 |
??? |
15.6 |
-2147483648 |
-2147483648 |
-1.00 -1.00 |
152928 |
4 |
36 |
209 |
0.7 1.0 |
6 |
29 |
ON |
7.9 |
H |
400 |
37 |
ON |
- oversampling freq not a multiple of loop freq |
20110427_113208 |
??? |
15.6 |
-2147483648 |
-2147483648 |
-1.00 -1.00 |
152928 |
4 |
36 |
209 |
0.7 1.0 |
6 |
29 |
ON |
-1.0 |
? |
-1 |
-1 |
ON |
- oversampling freq not a multiple of loop freq |
20110427_113245 |
??? |
15.6 |
-2147483648 |
-2147483648 |
-1.00 -1.00 |
152928 |
4 |
36 |
209 |
0.7 1.0 |
6 |
29 |
ON |
8.2 |
H |
400 |
37 |
ON |
- oversampling freq not a multiple of loop freq |
20110427_113323 |
??? |
15.7 |
-2147483648 |
-2147483648 |
-1.00 -1.00 |
152928 |
4 |
36 |
209 |
0.7 1.0 |
6 |
28 |
ON |
8.3 |
H |
400 |
37 |
ON |
- oversampling freq not a multiple of loop freq |
RON test: tutto acceso tranne CUBE e LAMP
Bin: 1 - Framerate 990 Hz (2500 kpix/sec) - RON (e-): 9.14 (estimated)
Bin: 2 - Framerate 990 Hz ( 800 kpix/sec) - RON (e-): 6.32 (estimated)
Bin: 2 - Framerate 625 Hz ( 380 kpix/sec) - RON (e-): 4.09 (estimated)
Bin: 2 - Framerate 400 Hz ( 380 kpix/sec) - RON (e-): 4.07 (estimated)
Bin: 3 - Framerate 200 Hz ( 380 kpix/sec) - RON (e-): 4.25 (estimated)
Bin: 4 - Framerate 300 Hz ( 335 kpix/sec) - RON (e-): 4.32 (estimated)
Bin: 4 - Framerate 200 Hz ( 335 kpix/sec) - RON (e-): 4.32 (estimated)
Bin: 4 - Framerate 105 Hz ( 335 kpix/sec) - RON (e-): 4.36 (estimated)
Mag13.5
Autogain tenuto basso volutamente perche' il valore originale (fino a 2.5) mandava tutto in skip frame
TrackNo |
RefStar |
Mag |
El |
Wind |
DIMM/OL |
Rec |
bin |
#mod |
freq |
gain |
mod |
nph |
AntiDrift |
SR |
band |
exp |
#frames |
disturb |
notes |
20110427_170243 |
??? |
13.5 |
-2147483648 |
-2147483648 |
-1.00 -1.00 |
171410 |
3 |
66 |
400 |
0.7 0.9 |
6 |
59 |
ON |
24.3 |
H |
100 |
150 |
ON |
|
20110427_170334 |
??? |
13.5 |
-2147483648 |
-2147483648 |
-1.00 -1.00 |
171410 |
3 |
66 |
400 |
0.7 0.9 |
6 |
59 |
ON |
24.9 |
H |
100 |
150 |
ON |
|
20110427_170426 |
??? |
13.5 |
-2147483648 |
-2147483648 |
-1.00 -1.00 |
171410 |
3 |
66 |
400 |
0.7 0.9 |
6 |
58 |
ON |
24.1 |
H |
100 |
150 |
ON |
|
20110427_170613 |
??? |
13.5 |
-2147483648 |
-2147483648 |
-1.00 -1.00 |
171410 |
3 |
66 |
400 |
0.7 0.9 |
6 |
55 |
ON |
23.4 |
H |
100 |
150 |
ON |
|
20110427_170705 |
??? |
13.4 |
-2147483648 |
-2147483648 |
-1.00 -1.00 |
171410 |
3 |
66 |
400 |
0.7 0.9 |
6 |
60 |
ON |
23.4 |
H |
100 |
150 |
ON |
|
20110427_170756 |
??? |
13.5 |
-2147483648 |
-2147483648 |
-1.00 -1.00 |
171410 |
3 |
66 |
400 |
0.7 0.9 |
6 |
58 |
ON |
23.8 |
H |
100 |
150 |
ON |
|
Increased gain ranges, but did binning 2:
TrackNo |
RefStar |
Mag |
El |
Wind |
DIMM/OL |
Rec |
bin |
#mod |
freq |
gain |
mod |
nph |
AntiDrift |
SR |
band |
exp |
#frames |
disturb |
notes |
20110427_172110 |
??? |
13.3 |
-2147483648 |
-2147483648 |
-1.00 -1.00 |
154434 |
2 |
120 |
400 |
0.5 0.8 |
3 |
29 |
ON |
39.1 |
H |
100 |
150 |
ON |
|
20110427_172201 |
??? |
13.3 |
-2147483648 |
-2147483648 |
-1.00 -1.00 |
154434 |
2 |
120 |
400 |
0.5 0.8 |
3 |
29 |
ON |
41.4 |
H |
100 |
150 |
ON |
|
20110427_172253 |
??? |
13.2 |
-2147483648 |
-2147483648 |
-1.00 -1.00 |
154434 |
2 |
120 |
400 |
0.5 0.8 |
3 |
31 |
ON |
40.3 |
H |
100 |
150 |
ON |
|
20110427_172441 |
??? |
13.3 |
-2147483648 |
-2147483648 |
-1.00 -1.00 |
154434 |
2 |
120 |
400 |
0.5 0.8 |
3 |
29 |
ON |
40.9 |
H |
100 |
150 |
ON |
|
20110427_172532 |
??? |
13.3 |
-2147483648 |
-2147483648 |
-1.00 -1.00 |
154434 |
2 |
120 |
400 |
0.5 0.8 |
3 |
30 |
ON |
41.1 |
H |
100 |
150 |
ON |
|
20110427_172624 |
??? |
13.2 |
-2147483648 |
-2147483648 |
-1.00 -1.00 |
154434 |
2 |
120 |
400 |
0.5 0.8 |
3 |
31 |
ON |
39.1 |
H |
100 |
150 |
ON |
|
Changing light source from 120 to 118
TrackNo |
RefStar |
Mag |
El |
Wind |
DIMM/OL |
Rec |
bin |
#mod |
freq |
gain |
mod |
nph |
AntiDrift |
SR |
band |
exp |
#frames |
disturb |
notes |
20110427_173432 |
??? |
13.6 |
-2147483648 |
-2147483648 |
-1.00 -1.00 |
171410 |
3 |
66 |
400 |
0.7 0.9 |
6 |
52 |
ON |
19.8 |
H |
100 |
150 |
ON |
|
20110427_173524 |
??? |
13.6 |
-2147483648 |
-2147483648 |
-1.00 -1.00 |
171410 |
3 |
66 |
400 |
0.7 0.9 |
6 |
52 |
ON |
20.6 |
H |
100 |
150 |
ON |
|
20110427_173615 |
??? |
13.6 |
-2147483648 |
-2147483648 |
-1.00 -1.00 |
171410 |
3 |
66 |
400 |
0.7 0.9 |
6 |
54 |
ON |
21.8 |
H |
100 |
150 |
ON |
|
20110427_173803 |
??? |
13.6 |
-2147483648 |
-2147483648 |
-1.00 -1.00 |
171410 |
3 |
66 |
400 |
0.7 0.9 |
6 |
53 |
ON |
21.3 |
H |
100 |
150 |
ON |
|
20110427_173854 |
??? |
13.6 |
-2147483648 |
-2147483648 |
-1.00 -1.00 |
171410 |
3 |
66 |
400 |
0.7 0.9 |
6 |
54 |
ON |
21.5 |
H |
100 |
150 |
ON |
|
20110427_173946 |
??? |
13.6 |
-2147483648 |
-2147483648 |
-1.00 -1.00 |
171410 |
3 |
66 |
400 |
0.7 0.9 |
6 |
53 |
ON |
21.0 |
H |
100 |
150 |
ON |
|
Trying mag 14.5
TrackNo |
RefStar |
Mag |
El |
Wind |
DIMM/OL |
Rec |
bin |
#mod |
freq |
gain |
mod |
nph |
AntiDrift |
SR |
band |
exp |
#frames |
disturb |
notes |
20110427_181310 |
??? |
14.8 |
-2147483648 |
-2147483648 |
-1.00 -1.00 |
152928 |
4 |
36 |
312 |
0.7 0.7 |
6 |
40 |
ON |
14.9 |
H |
300 |
50 |
ON |
- oversampling freq not a multiple of loop freq |
20110427_181344 |
??? |
14.9 |
-2147483648 |
-2147483648 |
-1.00 -1.00 |
152928 |
4 |
36 |
312 |
0.7 0.7 |
6 |
39 |
ON |
14.9 |
H |
300 |
50 |
ON |
- oversampling freq not a multiple of loop freq |
20110427_181418 |
??? |
14.9 |
-2147483648 |
-2147483648 |
-1.00 -1.00 |
152928 |
4 |
36 |
312 |
0.7 0.7 |
6 |
38 |
ON |
14.2 |
H |
300 |
50 |
ON |
- oversampling freq not a multiple of loop freq |
20110427_181533 |
??? |
15.0 |
-2147483648 |
-2147483648 |
-1.00 -1.00 |
152928 |
4 |
36 |
312 |
0.7 0.7 |
6 |
36 |
ON |
14.4 |
H |
300 |
50 |
ON |
- oversampling freq not a multiple of loop freq |
20110427_181607 |
??? |
15.0 |
-2147483648 |
-2147483648 |
-1.00 -1.00 |
152928 |
4 |
36 |
312 |
0.7 0.7 |
6 |
36 |
ON |
14.2 |
H |
300 |
50 |
ON |
- oversampling freq not a multiple of loop freq |
20110427_181641 |
??? |
14.9 |
-2147483648 |
-2147483648 |
-1.00 -1.00 |
152928 |
4 |
36 |
312 |
0.7 0.7 |
6 |
36 |
ON |
13.4 |
H |
300 |
50 |
ON |
- oversampling freq not a multiple of loop freq |
Mag 13.5 (lamp 119)
TrackNo |
RefStar |
Mag |
El |
Wind |
DIMM/OL |
Rec |
bin |
#mod |
freq |
gain |
mod |
nph |
AntiDrift |
SR |
band |
exp |
#frames |
disturb |
notes |
20110427_182729 |
??? |
13.6 |
-2147483648 |
-2147483648 |
-1.00 -1.00 |
171410 |
3 |
66 |
400 |
0.7 0.9 |
6 |
51 |
ON |
23.5 |
H |
100 |
150 |
ON |
|
20110427_182821 |
??? |
13.6 |
-2147483648 |
-2147483648 |
-1.00 -1.00 |
171410 |
3 |
66 |
400 |
0.7 0.9 |
6 |
53 |
ON |
23.7 |
H |
100 |
150 |
ON |
|
20110427_182912 |
??? |
13.6 |
-2147483648 |
-2147483648 |
-1.00 -1.00 |
171410 |
3 |
66 |
400 |
0.7 0.9 |
6 |
53 |
ON |
26.0 |
H |
100 |
150 |
ON |
|
20110427_183100 |
??? |
13.6 |
-2147483648 |
-2147483648 |
-1.00 -1.00 |
171410 |
3 |
66 |
400 |
0.7 0.9 |
6 |
51 |
ON |
24.5 |
H |
100 |
150 |
ON |
|
20110427_183151 |
??? |
13.6 |
-2147483648 |
-2147483648 |
-1.00 -1.00 |
171410 |
3 |
66 |
400 |
0.7 0.9 |
6 |
53 |
ON |
25.0 |
H |
100 |
150 |
ON |
|
20110427_183243 |
??? |
13.6 |
-2147483648 |
-2147483648 |
-1.00 -1.00 |
171410 |
3 |
66 |
400 |
0.7 0.9 |
6 |
54 |
ON |
25.6 |
H |
100 |
150 |
ON |
|