PRESA A MURO ACCANTO ALLA SCALA DELLA TORRE (circuito 3)

OFF: niente (tutto acceso)


SUMMARY ------------------------------------
Bin: 1 - Framerate 990 Hz (2500 kpix/sec) - RON (e-): 8.94 (estimated)
Bin: 2 - Framerate 990 Hz ( 800 kpix/sec) - RON (e-): 6.72 (estimated)
Bin: 2 - Framerate 625 Hz ( 380 kpix/sec) - RON (e-): 6.03 (estimated)
Bin: 2 - Framerate 400 Hz ( 380 kpix/sec) - RON (e-): 6.21 (estimated)
Bin: 3 - Framerate 200 Hz ( 380 kpix/sec) - RON (e-): 6.51 (estimated)
Bin: 4 - Framerate 300 Hz ( 335 kpix/sec) - RON (e-): 6.94 (estimated)
Bin: 4 - Framerate 200 Hz ( 335 kpix/sec) - RON (e-): 7.21 (estimated)
Bin: 4 - Framerate 105 Hz ( 335 kpix/sec) - RON (e-): 7.02 (estimated)

OFF: ADC, RIROT, FW


SUMMARY ------------------------------------
Bin: 1 - Framerate 990 Hz (2500 kpix/sec) - RON (e-): 8.89 (estimated)
Bin: 2 - Framerate 990 Hz ( 800 kpix/sec) - RON (e-): 6.48 (estimated)
Bin: 2 - Framerate 625 Hz ( 380 kpix/sec) - RON (e-): 4.54 (estimated)
Bin: 2 - Framerate 400 Hz ( 380 kpix/sec) - RON (e-): 4.61 (estimated)
Bin: 3 - Framerate 200 Hz ( 380 kpix/sec) - RON (e-): 4.68 (estimated)
Bin: 4 - Framerate 300 Hz ( 335 kpix/sec) - RON (e-): 5.22 (estimated)
Bin: 4 - Framerate 200 Hz ( 335 kpix/sec) - RON (e-): 4.82 (estimated)
Bin: 4 - Framerate 105 Hz ( 335 kpix/sec) - RON (e-): 4.92 (estimated)

OFF: ADC, RIROT
------------------------------ SUMMARY ------------------------------------
Bin: 1 - Framerate 990 Hz (2500 kpix/sec) - RON (e-): 9.04 (estimated)
Bin: 2 - Framerate 990 Hz ( 800 kpix/sec) - RON (e-): 6.58 (estimated)
Bin: 2 - Framerate 625 Hz ( 380 kpix/sec) - RON (e-): 4.91 (estimated)
Bin: 2 - Framerate 400 Hz ( 380 kpix/sec) - RON (e-): 4.92 (estimated)
Bin: 3 - Framerate 200 Hz ( 380 kpix/sec) - RON (e-): 5.24 (estimated)
Bin: 4 - Framerate 300 Hz ( 335 kpix/sec) - RON (e-): 5.64 (estimated)
Bin: 4 - Framerate 200 Hz ( 335 kpix/sec) - RON (e-): 5.82 (estimated)
Bin: 4 - Framerate 105 Hz ( 335 kpix/sec) - RON (e-): 5.51 (estimated)

Fri Apr 8 10:47:33 CEST 2011
OFF: ADC, RIROT, stage motors
------------------------------ SUMMARY ------------------------------------
Bin: 1 - Framerate 990 Hz (2500 kpix/sec) - RON (e-): 9.04 (estimated)
Bin: 2 - Framerate 990 Hz ( 800 kpix/sec) - RON (e-): 6.58 (estimated)
Bin: 2 - Framerate 625 Hz ( 380 kpix/sec) - RON (e-): 4.91 (estimated)
Bin: 2 - Framerate 400 Hz ( 380 kpix/sec) - RON (e-): 4.92 (estimated)
Bin: 3 - Framerate 200 Hz ( 380 kpix/sec) - RON (e-): 5.24 (estimated)
Bin: 4 - Framerate 300 Hz ( 335 kpix/sec) - RON (e-): 5.64 (estimated)
Bin: 4 - Framerate 200 Hz ( 335 kpix/sec) - RON (e-): 5.82 (estimated)
Bin: 4 - Framerate 105 Hz ( 335 kpix/sec) - RON (e-): 5.51 (estimated)


trasformatore portatile al 220 a parete senza terra

Il background fluttua pesantemente

OFF: stages

OFF: ADC, RIROT, FW, STAGES

OFF: ADC, RIROT, STAGES

PRESA A MURO ACCANTO ALLA PORTA IN ALTO A SX (CIRCUITO 5)

OFF: stages

Bin: 1 - Framerate 990 Hz (2500 kpix/sec) - RON (e-): 9.31 (estimated)
Bin: 2 - Framerate 990 Hz ( 800 kpix/sec) - RON (e-): 7.10 (estimated)
Bin: 2 - Framerate 625 Hz ( 380 kpix/sec) - RON (e-): 7.45 (estimated)
Bin: 2 - Framerate 400 Hz ( 380 kpix/sec) - RON (e-): 6.89 (estimated)
Bin: 3 - Framerate 200 Hz ( 380 kpix/sec) - RON (e-): 7.48 (estimated)
Bin: 4 - Framerate 300 Hz ( 335 kpix/sec) - RON (e-): 7.83 (estimated)
Bin: 4 - Framerate 200 Hz ( 335 kpix/sec) - RON (e-): 8.45 (estimated)
Bin: 4 - Framerate 105 Hz ( 335 kpix/sec) - RON (e-): 7.83 (estimated)

OFF: ADC, RIROT, FW, STAGES, CUBE

Bin: 1 - Framerate 990 Hz (2500 kpix/sec) - RON (e-): 9.36 (estimated)
Bin: 2 - Framerate 990 Hz ( 800 kpix/sec) - RON (e-): 6.86 (estimated)
Bin: 2 - Framerate 625 Hz ( 380 kpix/sec) - RON (e-): 5.78 (estimated)
Bin: 2 - Framerate 400 Hz ( 380 kpix/sec) - RON (e-): 5.78 (estimated)
Bin: 3 - Framerate 200 Hz ( 380 kpix/sec) - RON (e-): 6.15 (estimated)
Bin: 4 - Framerate 300 Hz ( 335 kpix/sec) - RON (e-): 6.53 (estimated)
Bin: 4 - Framerate 200 Hz ( 335 kpix/sec) - RON (e-): 6.49 (estimated)
Bin: 4 - Framerate 105 Hz ( 335 kpix/sec) - RON (e-): 6.49 (estimated)

OFF: ADC, RIROT, STAGES

Bin: 1 - Framerate 990 Hz (2500 kpix/sec) - RON (e-): 9.53 (estimated)
Bin: 2 - Framerate 990 Hz ( 800 kpix/sec) - RON (e-): 7.08 (estimated)
Bin: 2 - Framerate 625 Hz ( 380 kpix/sec) - RON (e-): 6.53 (estimated)
Bin: 2 - Framerate 400 Hz ( 380 kpix/sec) - RON (e-): 6.51 (estimated)
Bin: 3 - Framerate 200 Hz ( 380 kpix/sec) - RON (e-): 6.81 (estimated)
Bin: 4 - Framerate 300 Hz ( 335 kpix/sec) - RON (e-): 7.41 (estimated)
Bin: 4 - Framerate 200 Hz ( 335 kpix/sec) - RON (e-): 7.35 (estimated)
Bin: 4 - Framerate 105 Hz ( 335 kpix/sec) - RON (e-): 7.56 (estimated)

OFF: ADC, RIROT, STAGES, CUBE

Bin: 1 - Framerate 990 Hz (2500 kpix/sec) - RON (e-): 9.48 (estimated)
Bin: 2 - Framerate 990 Hz ( 800 kpix/sec) - RON (e-): 7.09 (estimated)
Bin: 2 - Framerate 625 Hz ( 380 kpix/sec) - RON (e-): 6.37 (estimated)
Bin: 2 - Framerate 400 Hz ( 380 kpix/sec) - RON (e-): 6.42 (estimated)
Bin: 3 - Framerate 200 Hz ( 380 kpix/sec) - RON (e-): 6.93 (estimated)
Bin: 4 - Framerate 300 Hz ( 335 kpix/sec) - RON (e-): 7.31 (estimated)
Bin: 4 - Framerate 200 Hz ( 335 kpix/sec) - RON (e-): 6.99 (estimated)
Bin: 4 - Framerate 105 Hz ( 335 kpix/sec) - RON (e-): 7.32 (estimated)

PRESA A MURO ACCANTO ALLA PORTA IN ALTO A DX (CIRCUITO 1)

OFF: stages

Bin: 1 - Framerate 990 Hz (2500 kpix/sec) - RON (e-): 9.13 (estimated)
Bin: 2 - Framerate 990 Hz ( 800 kpix/sec) - RON (e-): 6.94 (estimated)
Bin: 2 - Framerate 625 Hz ( 380 kpix/sec) - RON (e-): 6.25 (estimated)
Bin: 2 - Framerate 400 Hz ( 380 kpix/sec) - RON (e-): 6.28 (estimated)
Bin: 3 - Framerate 200 Hz ( 380 kpix/sec) - RON (e-): 6.58 (estimated)
Bin: 4 - Framerate 300 Hz ( 335 kpix/sec) - RON (e-): 7.03 (estimated)
Bin: 4 - Framerate 200 Hz ( 335 kpix/sec) - RON (e-): 7.10 (estimated)
Bin: 4 - Framerate 105 Hz ( 335 kpix/sec) - RON (e-): 6.98 (estimated)

OFF: ADC, RIROT, FW, STAGES

Bin: 1 - Framerate 990 Hz (2500 kpix/sec) - RON (e-): 9.06 (estimated)
Bin: 2 - Framerate 990 Hz ( 800 kpix/sec) - RON (e-): 6.79 (estimated)
Bin: 2 - Framerate 625 Hz ( 380 kpix/sec) - RON (e-): 5.62 (estimated)
Bin: 2 - Framerate 400 Hz ( 380 kpix/sec) - RON (e-): 5.65 (estimated)
Bin: 3 - Framerate 200 Hz ( 380 kpix/sec) - RON (e-): 5.92 (estimated)
Bin: 4 - Framerate 300 Hz ( 335 kpix/sec) - RON (e-): 6.37 (estimated)
Bin: 4 - Framerate 200 Hz ( 335 kpix/sec) - RON (e-): 6.35 (estimated)
Bin: 4 - Framerate 105 Hz ( 335 kpix/sec) - RON (e-): 6.38 (estimated)

OFF: ADC, RIROT, STAGES

Bin: 1 - Framerate 990 Hz (2500 kpix/sec) - RON (e-): 9.19 (estimated)
Bin: 2 - Framerate 990 Hz ( 800 kpix/sec) - RON (e-): 6.85 (estimated)
Bin: 2 - Framerate 625 Hz ( 380 kpix/sec) - RON (e-): 5.80 (estimated)
Bin: 2 - Framerate 400 Hz ( 380 kpix/sec) - RON (e-): 5.87 (estimated)
Bin: 3 - Framerate 200 Hz ( 380 kpix/sec) - RON (e-): 6.19 (estimated)
Bin: 4 - Framerate 300 Hz ( 335 kpix/sec) - RON (e-): 6.64 (estimated)
Bin: 4 - Framerate 200 Hz ( 335 kpix/sec) - RON (e-): 6.57 (estimated)
Bin: 4 - Framerate 105 Hz ( 335 kpix/sec) - RON (e-): 6.67 (estimated)

OFF: ADC, RIROT, FW, STAGES, CUBE

Bin: 1 - Framerate 990 Hz (2500 kpix/sec) - RON (e-): 9.00 (estimated)
Bin: 2 - Framerate 990 Hz ( 800 kpix/sec) - RON (e-): 6.77 (estimated)
Bin: 2 - Framerate 625 Hz ( 380 kpix/sec) - RON (e-): 5.57 (estimated)
Bin: 2 - Framerate 400 Hz ( 380 kpix/sec) - RON (e-): 5.62 (estimated)
Bin: 3 - Framerate 200 Hz ( 380 kpix/sec) - RON (e-): 5.85 (estimated)
Bin: 4 - Framerate 300 Hz ( 335 kpix/sec) - RON (e-): 6.21 (estimated)
Bin: 4 - Framerate 200 Hz ( 335 kpix/sec) - RON (e-): 6.13 (estimated)
Bin: 4 - Framerate 105 Hz ( 335 kpix/sec) - RON (e-): 6.27 (estimated)

PRESA A MURO SOPRA SCRIVANIA SECONDARIO (CIRCUITO 2)

OFF: stages

Bin: 1 - Framerate 990 Hz (2500 kpix/sec) - RON (e-): 9.35 (estimated)
Bin: 2 - Framerate 990 Hz ( 800 kpix/sec) - RON (e-): 7.01 (estimated)
Bin: 2 - Framerate 625 Hz ( 380 kpix/sec) - RON (e-): 6.42 (estimated)
Bin: 2 - Framerate 400 Hz ( 380 kpix/sec) - RON (e-): 6.44 (estimated)
Bin: 3 - Framerate 200 Hz ( 380 kpix/sec) - RON (e-): 6.82 (estimated)
Bin: 4 - Framerate 300 Hz ( 335 kpix/sec) - RON (e-): 7.24 (estimated)
Bin: 4 - Framerate 200 Hz ( 335 kpix/sec) - RON (e-): 7.36 (estimated)
Bin: 4 - Framerate 105 Hz ( 335 kpix/sec) - RON (e-): 7.21 (estimated)

OFF: ADC, RIROT, FW, STAGES

Bin: 1 - Framerate 990 Hz (2500 kpix/sec) - RON (e-): 9.34 (estimated)
Bin: 2 - Framerate 990 Hz ( 800 kpix/sec) - RON (e-): 6.89 (estimated)
Bin: 2 - Framerate 625 Hz ( 380 kpix/sec) - RON (e-): 5.79 (estimated)
Bin: 2 - Framerate 400 Hz ( 380 kpix/sec) - RON (e-): 5.78 (estimated)
Bin: 3 - Framerate 200 Hz ( 380 kpix/sec) - RON (e-): 6.16 (estimated)
Bin: 4 - Framerate 300 Hz ( 335 kpix/sec) - RON (e-): 6.41 (estimated)
Bin: 4 - Framerate 200 Hz ( 335 kpix/sec) - RON (e-): 6.51 (estimated)
Bin: 4 - Framerate 105 Hz ( 335 kpix/sec) - RON (e-): 6.54 (estimated)

OFF: ADC, RIROT, STAGES

Bin: 1 - Framerate 990 Hz (2500 kpix/sec) - RON (e-): 9.46 (estimated)
Bin: 2 - Framerate 990 Hz ( 800 kpix/sec) - RON (e-): 6.97 (estimated)
Bin: 2 - Framerate 625 Hz ( 380 kpix/sec) - RON (e-): 5.89 (estimated)
Bin: 2 - Framerate 400 Hz ( 380 kpix/sec) - RON (e-): 5.94 (estimated)
Bin: 3 - Framerate 200 Hz ( 380 kpix/sec) - RON (e-): 6.31 (estimated)
Bin: 4 - Framerate 300 Hz ( 335 kpix/sec) - RON (e-): 6.69 (estimated)
Bin: 4 - Framerate 200 Hz ( 335 kpix/sec) - RON (e-): 6.67 (estimated)
Bin: 4 - Framerate 105 Hz ( 335 kpix/sec) - RON (e-): 6.76 (estimated)

OFF: ADC, RIROT, FW, STAGES, CUBE

Bin: 1 - Framerate 990 Hz (2500 kpix/sec) - RON (e-): 9.31 (estimated)
Bin: 2 - Framerate 990 Hz ( 800 kpix/sec) - RON (e-): 6.85 (estimated)
Bin: 2 - Framerate 625 Hz ( 380 kpix/sec) - RON (e-): 5.68 (estimated)
Bin: 2 - Framerate 400 Hz ( 380 kpix/sec) - RON (e-): 5.71 (estimated)
Bin: 3 - Framerate 200 Hz ( 380 kpix/sec) - RON (e-): 6.03 (estimated)
Bin: 4 - Framerate 300 Hz ( 335 kpix/sec) - RON (e-): 6.36 (estimated)
Bin: 4 - Framerate 200 Hz ( 335 kpix/sec) - RON (e-): 6.31 (estimated)
Bin: 4 - Framerate 105 Hz ( 335 kpix/sec) - RON (e-): 6.45 (estimated)

PRESA A MURO SOPRA SCRIVANIA WFS (CIRCUITO 4)

OFF: stages

Bin: 1 - Framerate 990 Hz (2500 kpix/sec) - RON (e-): 9.14 (estimated)

Bin: 2 - Framerate 990 Hz ( 800 kpix/sec) - RON (e-): 6.79 (estimated)
Bin: 2 - Framerate 625 Hz ( 380 kpix/sec) - RON (e-): 5.79 (estimated)
Bin: 2 - Framerate 400 Hz ( 380 kpix/sec) - RON (e-): 5.85 (estimated)
Bin: 3 - Framerate 200 Hz ( 380 kpix/sec) - RON (e-): 6.18 (estimated)
Bin: 4 - Framerate 300 Hz ( 335 kpix/sec) - RON (e-): 6.44 (estimated)
Bin: 4 - Framerate 200 Hz ( 335 kpix/sec) - RON (e-): 6.59 (estimated)
Bin: 4 - Framerate 105 Hz ( 335 kpix/sec) - RON (e-): 6.52 (estimated)

OFF: ADC, RIROT, FW, STAGES

Bin: 1 - Framerate 990 Hz (2500 kpix/sec) - RON (e-): 9.15 (estimated)
Bin: 2 - Framerate 990 Hz ( 800 kpix/sec) - RON (e-): 6.69 (estimated)
Bin: 2 - Framerate 625 Hz ( 380 kpix/sec) - RON (e-): 5.13 (estimated)
Bin: 2 - Framerate 400 Hz ( 380 kpix/sec) - RON (e-): 5.13 (estimated)
Bin: 3 - Framerate 200 Hz ( 380 kpix/sec) - RON (e-): 5.36 (estimated)
Bin: 4 - Framerate 300 Hz ( 335 kpix/sec) - RON (e-): 5.70 (estimated)
Bin: 4 - Framerate 200 Hz ( 335 kpix/sec) - RON (e-): 5.69 (estimated)
Bin: 4 - Framerate 105 Hz ( 335 kpix/sec) - RON (e-): 5.74 (estimated)

OFF: ADC, RIROT, STAGES

Bin: 1 - Framerate 990 Hz (2500 kpix/sec) - RON (e-): 9.21 (estimated)
Bin: 2 - Framerate 990 Hz ( 800 kpix/sec) - RON (e-): 6.72 (estimated)
Bin: 2 - Framerate 625 Hz ( 380 kpix/sec) - RON (e-): 5.22 (estimated)
Bin: 2 - Framerate 400 Hz ( 380 kpix/sec) - RON (e-): 5.27 (estimated)
Bin: 3 - Framerate 200 Hz ( 380 kpix/sec) - RON (e-): 5.57 (estimated)
Bin: 4 - Framerate 300 Hz ( 335 kpix/sec) - RON (e-): 5.90 (estimated)
Bin: 4 - Framerate 200 Hz ( 335 kpix/sec) - RON (e-): 5.89 (estimated)
Bin: 4 - Framerate 105 Hz ( 335 kpix/sec) - RON (e-): 5.94 (estimated)

OFF: ADC, RIROT, FW, STAGES, CUBE

Bin: 1 - Framerate 990 Hz (2500 kpix/sec) - RON (e-): 9.04 (estimated)
Bin: 2 - Framerate 990 Hz ( 800 kpix/sec) - RON (e-): 6.68 (estimated)
Bin: 2 - Framerate 625 Hz ( 380 kpix/sec) - RON (e-): 5.00 (estimated)
Bin: 2 - Framerate 400 Hz ( 380 kpix/sec) - RON (e-): 5.01 (estimated)
Bin: 3 - Framerate 200 Hz ( 380 kpix/sec) - RON (e-): 5.26 (estimated)
Bin: 4 - Framerate 300 Hz ( 335 kpix/sec) - RON (e-): 5.53 (estimated)
Bin: 4 - Framerate 200 Hz ( 335 kpix/sec) - RON (e-): 5.56 (estimated)
Bin: 4 - Framerate 105 Hz ( 335 kpix/sec) - RON (e-): 5.59 (estimated)

PRESA A MURO ACCANTO ALLA SCALA DELLA TORRE (circuito 3) (RIPETIZIONE)

OFF: stages

Bin: 1 - Framerate 990 Hz (2500 kpix/sec) - RON (e-): 9.05 (estimated)
Bin: 2 - Framerate 990 Hz ( 800 kpix/sec) - RON (e-): 6.83 (estimated)
Bin: 2 - Framerate 625 Hz ( 380 kpix/sec) - RON (e-): 5.94 (estimated)
Bin: 2 - Framerate 400 Hz ( 380 kpix/sec) - RON (e-): 5.98 (estimated)
Bin: 3 - Framerate 200 Hz ( 380 kpix/sec) - RON (e-): 6.26 (estimated)
Bin: 4 - Framerate 300 Hz ( 335 kpix/sec) - RON (e-): 6.72 (estimated)
Bin: 4 - Framerate 200 Hz ( 335 kpix/sec) - RON (e-): 6.75 (estimated)
Bin: 4 - Framerate 105 Hz ( 335 kpix/sec) - RON (e-): 6.58 (estimated)

OFF: ADC, RIROT, FW, STAGES

Bin: 1 - Framerate 990 Hz (2500 kpix/sec) - RON (e-): 9.03 (estimated)
Bin: 2 - Framerate 990 Hz ( 800 kpix/sec) - RON (e-): 6.65 (estimated)
Bin: 2 - Framerate 625 Hz ( 380 kpix/sec) - RON (e-): 5.22 (estimated)
Bin: 2 - Framerate 400 Hz ( 380 kpix/sec) - RON (e-): 5.21 (estimated)
Bin: 3 - Framerate 200 Hz ( 380 kpix/sec) - RON (e-): 5.45 (estimated)
Bin: 4 - Framerate 300 Hz ( 335 kpix/sec) - RON (e-): 5.77 (estimated)
Bin: 4 - Framerate 200 Hz ( 335 kpix/sec) - RON (e-): 5.77 (estimated)
Bin: 4 - Framerate 105 Hz ( 335 kpix/sec) - RON (e-): 5.82 (estimated)

OFF: ADC, RIROT, STAGES

Bin: 1 - Framerate 990 Hz (2500 kpix/sec) - RON (e-): 9.14 (estimated)
Bin: 2 - Framerate 990 Hz ( 800 kpix/sec) - RON (e-): 6.74 (estimated)
Bin: 2 - Framerate 625 Hz ( 380 kpix/sec) - RON (e-): 5.40 (estimated)
Bin: 2 - Framerate 400 Hz ( 380 kpix/sec) - RON (e-): 5.43 (estimated)
Bin: 3 - Framerate 200 Hz ( 380 kpix/sec) - RON (e-): 5.73 (estimated)
Bin: 4 - Framerate 300 Hz ( 335 kpix/sec) - RON (e-): 6.13 (estimated)
Bin: 4 - Framerate 200 Hz ( 335 kpix/sec) - RON (e-): 6.08 (estimated)
Bin: 4 - Framerate 105 Hz ( 335 kpix/sec) - RON (e-): 6.11 (estimated)

OFF: ADC, RIROT, FW, STAGES, CUBE

Bin: 1 - Framerate 990 Hz (2500 kpix/sec) - RON (e-): 9.03 (estimated)
Bin: 2 - Framerate 990 Hz ( 800 kpix/sec) - RON (e-): 6.66 (estimated)
Bin: 2 - Framerate 625 Hz ( 380 kpix/sec) - RON (e-): 5.08 (estimated)
Bin: 2 - Framerate 400 Hz ( 380 kpix/sec) - RON (e-): 5.13 (estimated)
Bin: 3 - Framerate 200 Hz ( 380 kpix/sec) - RON (e-): 5.37 (estimated)
Bin: 4 - Framerate 300 Hz ( 335 kpix/sec) - RON (e-): 5.61 (estimated)
Bin: 4 - Framerate 200 Hz ( 335 kpix/sec) - RON (e-): 5.69 (estimated)
Bin: 4 - Framerate 105 Hz ( 335 kpix/sec) - RON (e-): 5.72 (estimated)

Riviste le spine del 110V ed eliminata la derivazione della multipla.

OFF: stages

Bin: 1 - Framerate 990 Hz (2500 kpix/sec) - RON (e-): 9.03 (estimated)
Bin: 2 - Framerate 990 Hz ( 800 kpix/sec) - RON (e-): 6.78 (estimated)
Bin: 2 - Framerate 625 Hz ( 380 kpix/sec) - RON (e-): 5.77 (estimated)
Bin: 2 - Framerate 400 Hz ( 380 kpix/sec) - RON (e-): 5.88 (estimated)
Bin: 3 - Framerate 200 Hz ( 380 kpix/sec) - RON (e-): 6.28 (estimated)
Bin: 4 - Framerate 300 Hz ( 335 kpix/sec) - RON (e-): 6.62 (estimated)
Bin: 4 - Framerate 200 Hz ( 335 kpix/sec) - RON (e-): 6.70 (estimated)
Bin: 4 - Framerate 105 Hz ( 335 kpix/sec) - RON (e-): 6.53 (estimated)

OFF: ADC, RIROT, FW, STAGES

Bin: 1 - Framerate 990 Hz (2500 kpix/sec) - RON (e-): 9.08 (estimated)
Bin: 2 - Framerate 990 Hz ( 800 kpix/sec) - RON (e-): 6.67 (estimated)
Bin: 2 - Framerate 625 Hz ( 380 kpix/sec) - RON (e-): 5.19 (estimated)
Bin: 2 - Framerate 400 Hz ( 380 kpix/sec) - RON (e-): 5.18 (estimated)
Bin: 3 - Framerate 200 Hz ( 380 kpix/sec) - RON (e-): 5.43 (estimated)
Bin: 4 - Framerate 300 Hz ( 335 kpix/sec) - RON (e-): 5.69 (estimated)
Bin: 4 - Framerate 200 Hz ( 335 kpix/sec) - RON (e-): 5.76 (estimated)
Bin: 4 - Framerate 105 Hz ( 335 kpix/sec) - RON (e-): 5.79 (estimated)

Spenti gli interruttori dei circuiti 1,2,4 e 5. Solo il circuito 3 rimane ON.

OFF: ADC, RIROT, FW, STAGES

Bin: 1 - Framerate 990 Hz (2500 kpix/sec) - RON (e-): 9.26 (estimated)
Bin: 2 - Framerate 990 Hz ( 800 kpix/sec) - RON (e-): 6.75 (estimated)
Bin: 2 - Framerate 625 Hz ( 380 kpix/sec) - RON (e-): 5.47 (estimated)
Bin: 2 - Framerate 400 Hz ( 380 kpix/sec) - RON (e-): 5.43 (estimated)
Bin: 3 - Framerate 200 Hz ( 380 kpix/sec) - RON (e-): 5.83 (estimated)
Bin: 4 - Framerate 300 Hz ( 335 kpix/sec) - RON (e-): 6.07 (estimated)
Bin: 4 - Framerate 200 Hz ( 335 kpix/sec) - RON (e-): 6.15 (estimated)
Bin: 4 - Framerate 105 Hz ( 335 kpix/sec) - RON (e-): 6.08 (estimated)



PAUSA PRANZO, sistema spento

Spenti gli interruttori dei circuiti 2 e 5. Solo il circuito 1 3 e 4 rimane ON.

OFF: ADC, RIROT, FW, STAGES, CUBE

Bin: 1 - Framerate 990 Hz (2500 kpix/sec) - RON (e-): 8.66 (estimated)
Bin: 2 - Framerate 990 Hz ( 800 kpix/sec) - RON (e-): 6.43 (estimated)
Bin: 2 - Framerate 625 Hz ( 380 kpix/sec) - RON (e-): 4.25 (estimated)
Bin: 2 - Framerate 400 Hz ( 380 kpix/sec) - RON (e-): 4.26 (estimated)
Bin: 3 - Framerate 200 Hz ( 380 kpix/sec) - RON (e-): 4.41 (estimated)
Bin: 4 - Framerate 300 Hz ( 335 kpix/sec) - RON (e-): 4.54 (estimated)
Bin: 4 - Framerate 200 Hz ( 335 kpix/sec) - RON (e-): 4.45 (estimated)
Bin: 4 - Framerate 105 Hz ( 335 kpix/sec) - RON (e-): 4.58 (estimated)

Tutti i 5 circuiti a 110V accesi.

OFF: ADC, RIROT, FW, STAGES, CUBE

Bin: 1 - Framerate 990 Hz (2500 kpix/sec) - RON (e-): 8.76 (estimated)
Bin: 2 - Framerate 990 Hz ( 800 kpix/sec) - RON (e-): 6.47 (estimated)
Bin: 2 - Framerate 625 Hz ( 380 kpix/sec) - RON (e-): 4.31 (estimated)
Bin: 2 - Framerate 400 Hz ( 380 kpix/sec) - RON (e-): 4.33 (estimated)
Bin: 3 - Framerate 200 Hz ( 380 kpix/sec) - RON (e-): 4.42 (estimated)
Bin: 4 - Framerate 300 Hz ( 335 kpix/sec) - RON (e-): 4.57 (estimated)
Bin: 4 - Framerate 200 Hz ( 335 kpix/sec) - RON (e-): 4.63 (estimated)
Bin: 4 - Framerate 105 Hz ( 335 kpix/sec) - RON (e-): 4.62 (estimated)

Bin: 1 - Framerate 990 Hz (2500 kpix/sec) - RON (e-): 8.87 (estimated)
Bin: 2 - Framerate 990 Hz ( 800 kpix/sec) - RON (e-): 6.51 (estimated)
Bin: 2 - Framerate 625 Hz ( 380 kpix/sec) - RON (e-): 4.29 (estimated)
Bin: 2 - Framerate 400 Hz ( 380 kpix/sec) - RON (e-): 4.31 (estimated)
Bin: 3 - Framerate 200 Hz ( 380 kpix/sec) - RON (e-): 4.41 (estimated)
Bin: 4 - Framerate 300 Hz ( 335 kpix/sec) - RON (e-): 4.50 (estimated)
Bin: 4 - Framerate 200 Hz ( 335 kpix/sec) - RON (e-): 4.53 (estimated)
Bin: 4 - Framerate 105 Hz ( 335 kpix/sec) - RON (e-): 4.58 (estimated)

temp0.png
  • temp0.png:
OFF: ADC, RIROT, FW, STAGES, CUBE
Time: 2:32 PM

Bin: 1 - Framerate 990 Hz (2500 kpix/sec) - RON (e-): 8.74 (estimated)
Bin: 2 - Framerate 990 Hz ( 800 kpix/sec) - RON (e-): 6.49 (estimated)
Bin: 2 - Framerate 625 Hz ( 380 kpix/sec) - RON (e-): 4.27 (estimated)
Bin: 2 - Framerate 400 Hz ( 380 kpix/sec) - RON (e-): 4.26 (estimated)
Bin: 3 - Framerate 200 Hz ( 380 kpix/sec) - RON (e-): 4.42 (estimated)
Bin: 4 - Framerate 300 Hz ( 335 kpix/sec) - RON (e-): 4.55 (estimated)
Bin: 4 - Framerate 200 Hz ( 335 kpix/sec) - RON (e-): 4.57 (estimated)
Bin: 4 - Framerate 105 Hz ( 335 kpix/sec) - RON (e-): 4.60 (estimated)

OFF: ADC, RIROT, FW, STAGES, CUBE
Time: 2:53 PM

Bin: 1 - Framerate 990 Hz (2500 kpix/sec) - RON (e-): 8.82 (estimated)
Bin: 2 - Framerate 990 Hz ( 800 kpix/sec) - RON (e-): 6.50 (estimated)
Bin: 2 - Framerate 625 Hz ( 380 kpix/sec) - RON (e-): 4.24 (estimated)
Bin: 2 - Framerate 400 Hz ( 380 kpix/sec) - RON (e-): 4.26 (estimated)
Bin: 3 - Framerate 200 Hz ( 380 kpix/sec) - RON (e-): 4.43 (estimated)
Bin: 4 - Framerate 300 Hz ( 335 kpix/sec) - RON (e-): 4.51 (estimated)
Bin: 4 - Framerate 200 Hz ( 335 kpix/sec) - RON (e-): 4.52 (estimated)
Bin: 4 - Framerate 105 Hz ( 335 kpix/sec) - RON (e-): 4.63 (estimated)

  • temp1.png:
    temp1.png
presa dati

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR band exp #frames disturb notes
20110408_145834 ??? 12.2 -2147483648 -2147483648 -1.00 -1.00 171951 2 153 625 0.4 0.6 3 53 ON 58.3 H 150 100 ON  
20110408_145907 ??? 12.2 -2147483648 -2147483648 -1.00 -1.00 171951 2 153 625 0.4 0.6 3 53 ON 56.5 H 150 100 ON SR may be in error
20110408_145940 ??? 12.2 -2147483648 -2147483648 -1.00 -1.00 171951 2 153 625 0.4 0.6 3 53 ON 57.5 H 150 100 ON  
20110408_150054 ??? 12.3 -2147483648 -2147483648 -1.00 -1.00 171951 2 153 625 0.4 0.6 3 50 ON 57.6 H 150 100 ON  
20110408_150127 ??? 12.2 -2147483648 -2147483648 -1.00 -1.00 171951 2 153 625 0.4 0.6 3 50 ON 58.8 H 150 100 ON  
20110408_150200 ??? 12.2 -2147483648 -2147483648 -1.00 -1.00 171951 2 153 625 0.4 0.6 3 52 ON 58.7 H 150 100 ON  
20110408_150239 ??? 12.2 -2147483648 -2147483648 -1.00 -1.00 171951 2 153 625 0.4 0.6 3 52 ON 59.9 H 150 100 ON  
20110408_150312 ??? 12.2 -2147483648 -2147483648 -1.00 -1.00 171951 2 153 625 0.4 0.6 3 53 ON 57.7 H 150 100 ON  
20110408_150344 ??? 12.2 -2147483648 -2147483648 -1.00 -1.00 171951 2 153 625 0.4 0.6 3 54 ON 57.7 H 150 100 ON  
20110408_150459 ??? 12.2 -2147483648 -2147483648 -1.00 -1.00 171951 2 153 625 0.4 0.6 3 52 ON 57.3 H 150 100 ON  
20110408_150531 ??? 12.2 -2147483648 -2147483648 -1.00 -1.00 171951 2 153 625 0.4 0.6 3 55 ON 56.5 H 150 100 ON  
20110408_150604 ??? 12.1 -2147483648 -2147483648 -1.00 -1.00 171951 2 153 625 0.4 0.6 3 56 ON 56.0 H 150 100 ON  

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR band exp #frames disturb notes
20110408_151120 ??? 12.5 -2147483648 -2147483648 -1.00 -1.00 171951 2 153 625 0.4 0.5 3 38 ON 54.3 H 150 100 ON  
20110408_151152 ??? 12.6 -2147483648 -2147483648 -1.00 -1.00 171951 2 153 625 0.4 0.5 3 37 ON 52.8 H 150 100 ON  
20110408_151225 ??? 12.5 -2147483648 -2147483648 -1.00 -1.00 171951 2 153 625 0.4 0.5 3 38 ON 53.6 H 150 100 ON  
20110408_151339 ??? 12.6 -2147483648 -2147483648 -1.00 -1.00 171951 2 153 625 0.4 0.5 3 36 ON 52.9 H 150 100 ON  
20110408_151412 ??? 12.5 -2147483648 -2147483648 -1.00 -1.00 171951 2 153 625 0.4 0.5 3 38 ON 53.8 H 150 100 ON  
20110408_151445 ??? 12.6 -2147483648 -2147483648 -1.00 -1.00 171951 2 153 625 0.4 0.5 3 37 ON 54.2 H 150 100 ON  
20110408_151608 ??? 12.5 -2147483648 -2147483648 -1.00 -1.00 171951 2 153 625 0.4 0.5 3 39 ON 54.7 H 150 100 ON  
20110408_151641 ??? 12.5 -2147483648 -2147483648 -1.00 -1.00 171951 2 153 625 0.4 0.5 3 39 ON 55.8 H 150 100 ON  
20110408_151714 ??? 12.5 -2147483648 -2147483648 -1.00 -1.00 171951 2 153 625 0.4 0.5 3 39 ON 55.2 H 150 100 ON  
20110408_151829 ??? 12.5 -2147483648 -2147483648 -1.00 -1.00 171951 2 153 625 0.4 0.5 3 38 ON 53.9 H 150 100 ON - long stop of 86 frames at frame 1915
20110408_151902 ??? 12.5 -2147483648 -2147483648 -1.00 -1.00 171951 2 153 625 0.4 0.5 3 41 ON 54.7 H 150 100 ON  
20110408_151934 ??? 12.4 -2147483648 -2147483648 -1.00 -1.00 171951 2 153 625 0.4 0.5 3 42 ON 55.6 H 150 100 ON  

tutto il gruppo seguente ha un problema di frequenza del disturbo!!
TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR band exp #frames disturb notes
20110408_152434 ??? 13.4 -2147483648 -2147483648 -1.00 -1.00 171951 2 153 400 0.5 0.6 3 27 ON 43.0 H 300 50 ON  
20110408_152459 ??? 13.5 -2147483648 -2147483648 -1.00 -1.00 171951 2 153 400 0.5 0.6 3 25 ON 43.5 H 300 50 ON SR may be in error
20110408_152523 ??? 13.5 -2147483648 -2147483648 -1.00 -1.00 171951 2 153 400 0.5 0.6 3 24 ON 42.9 H 300 50 ON  
20110408_152623 ??? 13.6 -2147483648 -2147483648 -1.00 -1.00 171951 2 153 400 0.5 0.6 3 22 ON 38.4 H 300 50 ON  
20110408_152647 ??? 13.6 -2147483648 -2147483648 -1.00 -1.00 171951 2 153 400 0.5 0.6 3 22 ON 40.6 H 300 50 ON  
20110408_152712 ??? 13.5 -2147483648 -2147483648 -1.00 -1.00 171951 2 153 400 0.5 0.6 3 24 ON 41.2 H 300 50 ON  
20110408_152813 ??? 13.4 -2147483648 -2147483648 -1.00 -1.00 171951 2 153 400 0.5 0.6 3 28 ON 41.3 H 300 50 ON  
20110408_152838 ??? 13.6 -2147483648 -2147483648 -1.00 -1.00 171951 2 153 400 0.5 0.6 3 22 ON 42.7 H 300 50 ON - long stop of 55 frames at frame 2562
20110408_152903 ??? 13.5 -2147483648 -2147483648 -1.00 -1.00 171951 2 153 400 0.5 0.6 3 25 ON 41.7 H 300 50 ON  
20110408_153003 ??? 13.6 -2147483648 -2147483648 -1.00 -1.00 171951 2 153 400 0.5 0.6 3 22 ON 37.8 H 300 50 ON SR may be in error
20110408_153028 ??? 13.5 -2147483648 -2147483648 -1.00 -1.00 171951 2 153 400 0.5 0.6 3 24 ON 40.6 H 300 50 ON SR may be in error
20110408_153052 ??? 13.5 -2147483648 -2147483648 -1.00 -1.00 171951 2 153 400 0.5 0.6 3 24 ON 40.6 H 300 50 ON  
OFF: ADC, RIROT, FW, STAGES, CUBE
Time: 3:36 PM

Bin: 1 - Framerate 990 Hz (2500 kpix/sec) - RON (e-): 8.66 (estimated)
Bin: 2 - Framerate 990 Hz ( 800 kpix/sec) - RON (e-): 6.52 (estimated)
Bin: 2 - Framerate 625 Hz ( 380 kpix/sec) - RON (e-): 4.30 (estimated)
Bin: 2 - Framerate 400 Hz ( 380 kpix/sec) - RON (e-): 4.31 (estimated)
Bin: 3 - Framerate 200 Hz ( 380 kpix/sec) - RON (e-): 4.41 (estimated)
Bin: 4 - Framerate 300 Hz ( 335 kpix/sec) - RON (e-): 4.55 (estimated)
Bin: 4 - Framerate 200 Hz ( 335 kpix/sec) - RON (e-): 4.57 (estimated)
Bin: 4 - Framerate 105 Hz ( 335 kpix/sec) - RON (e-): 4.57 (estimated)

nuovo rec BIN2 120 modes: 20110408_154434
TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR band exp #frames disturb notes
20110408_155152 ??? 13.5 -2147483648 -2147483648 -1.00 -1.00 154434 2 120 400 0.7 0.9 3 25 ON 30.3 H 350 50 ON  
20110408_155219 ??? 13.4 -2147483648 -2147483648 -1.00 -1.00 154434 2 120 400 0.7 0.9 3 26 ON 30.3 H 350 50 ON  
20110408_155248 ??? 13.5 -2147483648 -2147483648 -1.00 -1.00 154434 2 120 400 0.7 0.9 3 25 ON 26.5 H 350 50 ON  
20110408_155352 ??? 13.6 -2147483648 -2147483648 -1.00 -1.00 154434 2 120 400 0.7 0.9 3 22 ON 29.7 H 350 50 ON  
20110408_155419 ??? 13.5 -2147483648 -2147483648 -1.00 -1.00 154434 2 120 400 0.7 0.9 3 24 ON 31.2 H 350 50 ON  
20110408_155447 ??? 13.5 -2147483648 -2147483648 -1.00 -1.00 154434 2 120 400 0.7 0.9 3 25 ON 32.8 H 350 50 ON  
20110408_155559 ??? 13.5 -2147483648 -2147483648 -1.00 -1.00 154434 2 120 400 0.7 0.9 3 25 ON 31.5 H 350 50 ON  
20110408_155627 ??? 13.5 -2147483648 -2147483648 -1.00 -1.00 154434 2 120 400 0.7 0.9 3 24 ON 30.2 H 350 50 ON  
20110408_155655 ??? 13.5 -2147483648 -2147483648 -1.00 -1.00 154434 2 120 400 0.7 0.9 3 24 ON 28.6 H 350 50 ON  
20110408_155800 ??? 13.6 -2147483648 -2147483648 -1.00 -1.00 154434 2 120 400 0.7 0.9 3 22 ON 29.2 H 350 50 ON  
20110408_155827 ??? 13.6 -2147483648 -2147483648 -1.00 -1.00 154434 2 120 400 0.7 0.9 3 23 ON 30.3 H 350 50 ON  
20110408_155856 ??? 13.5 -2147483648 -2147483648 -1.00 -1.00 154434 2 120 400 0.7 0.9 3 24 ON 30.5 H 350 50 ON SR may be in error
OFF: ADC, RIROT, FW, STAGES, CUBE
Time: 4:09 PM

Bin: 1 - Framerate 990 Hz (2500 kpix/sec) - RON (e-): 8.68 (estimated)
Bin: 2 - Framerate 990 Hz ( 800 kpix/sec) - RON (e-): 6.45 (estimated)
Bin: 2 - Framerate 625 Hz ( 380 kpix/sec) - RON (e-): 4.27 (estimated)
Bin: 2 - Framerate 400 Hz ( 380 kpix/sec) - RON (e-): 4.30 (estimated)
Bin: 3 - Framerate 200 Hz ( 380 kpix/sec) - RON (e-): 4.41 (estimated)
Bin: 4 - Framerate 300 Hz ( 335 kpix/sec) - RON (e-): 4.59 (estimated)
Bin: 4 - Framerate 200 Hz ( 335 kpix/sec) - RON (e-): 4.57 (estimated)
Bin: 4 - Framerate 105 Hz ( 335 kpix/sec) - RON (e-): 4.64 (estimated)

BIN1 faint

Rifatto perché ieri la PSF era troppo vicina al bordo e dava quasi sempre "SR may be in error"

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR band exp #frames disturb notes
20110408_161316 ??? 10.6 -2147483648 -2147483648 -1.00 -1.00 151551 1 300 990 0.3 0.4 6 35 ON 65.5 H 70 150 ON - Pyramid modulation mismatch
20110408_161353 ??? 10.5 -2147483648 -2147483648 -1.00 -1.00 151551 1 300 990 0.3 0.4 6 39 ON 65.8 H 70 150 ON - Pyramid modulation mismatch
20110408_161431 ??? 10.6 -2147483648 -2147483648 -1.00 -1.00 151551 1 300 990 0.3 0.4 6 37 ON 64.4 H 70 150 ON - Pyramid modulation mismatch
20110408_161553 ??? 10.7 -2147483648 -2147483648 -1.00 -1.00 151551 1 300 990 0.3 0.4 6 32 ON 64.3 H 70 150 ON - Pyramid modulation mismatch
20110408_161631 ??? 10.6 -2147483648 -2147483648 -1.00 -1.00 151551 1 300 990 0.3 0.4 6 38 ON 68.2 H 70 150 ON - Pyramid modulation mismatch
20110408_161709 ??? 10.5 -2147483648 -2147483648 -1.00 -1.00 151551 1 300 990 0.3 0.4 6 40 ON 65.6 H 70 150 ON - Pyramid modulation mismatch

La modulazione era per sbaglio a 6 l/D, riproviamo.
TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR band exp #frames disturb notes
20110408_161948 ??? 10.7 -2147483648 -2147483648 -1.00 -1.00 151551 1 300 990 0.3 0.5 3 34 ON 69.6 H 70 150 ON  
20110408_162026 ??? 10.6 -2147483648 -2147483648 -1.00 -1.00 151551 1 300 990 0.3 0.5 3 38 ON 68.2 H 70 150 ON  
20110408_162103 ??? 10.6 -2147483648 -2147483648 -1.00 -1.00 151551 1 300 990 0.3 0.5 3 36 ON 67.9 H 70 150 ON  
20110408_162225 ??? 10.7 -2147483648 -2147483648 -1.00 -1.00 151551 1 300 990 0.3 0.5 3 34 ON 69.1 H 70 150 ON  
20110408_162302 ??? 10.7 -2147483648 -2147483648 -1.00 -1.00 151551 1 300 990 0.3 0.5 3 34 ON 70.1 H 70 150 ON  
20110408_162340 ??? 10.7 -2147483648 -2147483648 -1.00 -1.00 151551 1 300 990 0.3 0.5 3 34 ON 70.0 H 70 150 ON  
20110408_162503 ??? 10.6 -2147483648 -2147483648 -1.00 -1.00 151551 1 300 990 0.3 0.5 3 37 ON 70.8 H 70 150 ON  
20110408_162540 ??? 10.6 -2147483648 -2147483648 -1.00 -1.00 151551 1 300 990 0.3 0.5 3 36 ON 71.6 H 70 150 ON  
20110408_162619 ??? 10.6 -2147483648 -2147483648 -1.00 -1.00 151551 1 300 990 0.3 0.5 3 36 ON 70.4 H 70 150 ON  
20110408_162741 ??? 10.7 -2147483648 -2147483648 -1.00 -1.00 151551 1 300 990 0.3 0.5 3 34 ON 70.6 H 70 150 ON  
20110408_162818 ??? 10.6 -2147483648 -2147483648 -1.00 -1.00 151551 1 300 990 0.3 0.5 3 36 ON 70.8 H 70 150 ON  
20110408_162856 ??? 10.6 -2147483648 -2147483648 -1.00 -1.00 151551 1 300 990 0.3 0.5 3 37 ON 69.7 H 70 150 ON  
['20110408_161948','20110408_162026','20110408_162103','20110408_162225','20110408_162302','20110408_162340','20110408_162503','20110408_162540','20110408_162619','20110408_162741','20110408_162818','20110408_162856']

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR band exp #frames disturb notes
20110408_163954 ??? 11.1 -2147483648 -2147483648 -1.00 -1.00 151551 1 300 990 0.3 0.4 3 24 ON 60.9 H 100 150 ON  
20110408_164036 ??? 11.1 -2147483648 -2147483648 -1.00 -1.00 151551 1 300 990 0.3 0.4 3 23 ON 58.7 H 100 150 ON  
20110408_164118 ??? 11.2 -2147483648 -2147483648 -1.00 -1.00 151551 1 300 990 0.3 0.4 3 21 ON 58.1 H 100 150 ON  
20110408_164250 ??? 11.3 -2147483648 -2147483648 -1.00 -1.00 151551 1 300 990 0.3 0.4 3 19 ON 50.1 H 100 150 ON  
20110408_164334 ??? 11.3 -2147483648 -2147483648 -1.00 -1.00 151551 1 300 990 0.3 0.4 3 20 ON 52.0 H 100 150 ON  
20110408_164416 ??? 11.1 -2147483648 -2147483648 -1.00 -1.00 151551 1 300 990 0.3 0.4 3 22 ON 57.6 H 100 150 ON  
20110408_164533 ??? 11.2 -2147483648 -2147483648 -1.00 -1.00 151551 1 300 990 0.3 0.4 3 21 ON 55.7 H 100 150 ON  
20110408_164615 ??? 11.2 -2147483648 -2147483648 -1.00 -1.00 151551 1 300 990 0.3 0.4 3 20 ON 53.4 H 100 150 ON  
20110408_164657 ??? 11.2 -2147483648 -2147483648 -1.00 -1.00 151551 1 300 990 0.3 0.4 3 20 ON 56.1 H 100 150 ON  
20110408_164828 ??? 11.3 -2147483648 -2147483648 -1.00 -1.00 151551 1 300 990 0.3 0.4 3 20 ON 52.6 H 100 150 ON  
20110408_164910 ??? 11.3 -2147483648 -2147483648 -1.00 -1.00 151551 1 300 990 0.3 0.4 3 20 ON 51.9 H 100 150 ON  
20110408_164951 ??? 11.3 -2147483648 -2147483648 -1.00 -1.00 151551 1 300 990 0.3 0.4 3 19 ON 51.9 H 100 150 ON  

BIN3 intmat

10 modi

=======================================

DISTURBOIM 20110408_170647
Modal basis = kl_20110311
type = Push-pull
Frames per mov = 3
Cycle = 60
#Modes = 10
Amp = 600_optimized_6l
Note =

=======================================

INTMATACQ 20110408_170850
Pup = 20110131_173154
Dist = 20110408_170647
Iteration = 4
Loop speed = 700
bin = 3
Modul = 6
Rec.Close loop = None
Gain vector close loop = None

=======================================

REC 20110408_171000
Modal Basis: type
intmatacq = 20110408_170850
n modes = 10
TT removal = ON
cutted = 0
Note: ...............

=======================================

66 modi

=======================================

DISTURBOIM 20110408_171223
Modal basis = kl_20110311
type = Push-pull
Frames per mov = 3
Cycle = 9
#Modes = 66
Amp = 600_optimized_6l
Note =

=======================================

INTMATACQ 20110408_171251
Pup = 20110131_173154
Dist = 20110408_171223
Iteration = 4
Loop speed = 700
bin = 3
Modul = 6
Rec.Close loop = 20110408_171000
Gain vector close loop = 0.05
=======================================

REC 20110408_171410
Modal Basis: type
intmatacq = 20110408_171251
n modes = 66
TT removal = ON
cutted = 0
Note: ...............

=======================================

RON TEST ROTATORE

OFF: FW, ADC, CUBE, stages

Bin: 1 - Framerate 990 Hz (2500 kpix/sec) - RON (e-): 8.69 (estimated)
Bin: 2 - Framerate 990 Hz ( 800 kpix/sec) - RON (e-): 6.46 (estimated)
Bin: 2 - Framerate 625 Hz ( 380 kpix/sec) - RON (e-): 4.67 (estimated)
Bin: 2 - Framerate 400 Hz ( 380 kpix/sec) - RON (e-): 4.71 (estimated)
Bin: 3 - Framerate 200 Hz ( 380 kpix/sec) - RON (e-): 4.86 (estimated)
Bin: 4 - Framerate 300 Hz ( 335 kpix/sec) - RON (e-): 5.05 (estimated)
Bin: 4 - Framerate 200 Hz ( 335 kpix/sec) - RON (e-): 5.01 (estimated)
Bin: 4 - Framerate 105 Hz ( 335 kpix/sec) - RON (e-): 5.00 (estimated)

OFF: FW, ADC, REROT, CUBE, stages
Time: 17:37

Bin: 1 - Framerate 990 Hz (2500 kpix/sec) - RON (e-): 8.77 (estimated)
Bin: 2 - Framerate 990 Hz ( 800 kpix/sec) - RON (e-): 6.51 (estimated)
Bin: 2 - Framerate 625 Hz ( 380 kpix/sec) - RON (e-): 4.34 (estimated)
Bin: 2 - Framerate 400 Hz ( 380 kpix/sec) - RON (e-): 4.39 (estimated)
Bin: 3 - Framerate 200 Hz ( 380 kpix/sec) - RON (e-): 4.52 (estimated)
Bin: 4 - Framerate 300 Hz ( 335 kpix/sec) - RON (e-): 4.65 (estimated)
Bin: 4 - Framerate 200 Hz ( 335 kpix/sec) - RON (e-): 4.72 (estimated)
Bin: 4 - Framerate 105 Hz ( 335 kpix/sec) - RON (e-): 4.63 (estimated)

Ora mettiamo la AUX FW su POS2=1%

Facciamo il fuoco

Alla fine del primo giro di autofocus muore il MSGdaemon del secondario e ci fermiamo per qualche minuto

La posizione individuata per il POS2=1%; Zstage->53.08

cloop bin3 mag 13.4

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR band exp #frames disturb notes
20110408_174612 ??? 13.4 -2147483648 -2147483648 -1.00 -1.00 171410 3 66 200 1.3 1.4 6 125 ON 33.2 H 200 50 ON SR may be in error
20110408_174641 ??? 13.4 -2147483648 -2147483648 -1.00 -1.00 171410 3 66 200 1.3 1.4 6 125 ON 34.7 H 200 50 ON  
20110408_174710 ??? 13.4 -2147483648 -2147483648 -1.00 -1.00 171410 3 66 200 1.3 1.4 6 125 ON 34.3 H 200 50 ON SR may be in error
20110408_174809 ??? 13.5 -2147483648 -2147483648 -1.00 -1.00 171410 3 66 200 1.3 1.4 6 118 ON 33.5 H 200 50 ON  
20110408_174837 ??? 13.4 -2147483648 -2147483648 -1.00 -1.00 171410 3 66 200 1.3 1.4 6 120 ON 30.9 H 200 50 ON SR may be in error
20110408_174907 ??? 13.4 -2147483648 -2147483648 -1.00 -1.00 171410 3 66 200 1.3 1.4 6 122 ON 31.1 H 200 50 ON SR may be in error
20110408_175157 ??? 13.4 -2147483648 -2147483648 -1.00 -1.00 171410 3 66 200 1.3 1.4 6 122 ON 31.2 H 200 50 ON SR may be in error
20110408_175226 ??? 13.4 -2147483648 -2147483648 -1.00 -1.00 171410 3 66 200 1.3 1.4 6 122 ON 31.2 H 200 50 ON SR may be in error
20110408_175255 ??? 13.4 -2147483648 -2147483648 -1.00 -1.00 171410 3 66 200 1.3 1.4 6 122 ON 32.2 H 200 50 ON SR may be in error
20110408_175354 ??? 13.5 -2147483648 -2147483648 -1.00 -1.00 171410 3 66 200 1.3 1.4 6 118 ON 31.9 H 200 50 ON SR may be in error
20110408_175424 ??? 13.4 -2147483648 -2147483648 -1.00 -1.00 171410 3 66 200 1.3 1.4 6 123 ON 32.6 H 200 50 ON  
20110408_175452 ??? 13.4 -2147483648 -2147483648 -1.00 -1.00 171410 3 66 200 1.3 1.4 6 122 ON 31.2 H 200 50 ON  

Bin3 Mag14.5

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR band exp #frames disturb notes
20110408_175924 ??? 14.5 -2147483648 -2147483648 -1.00 -1.00 171410 3 66 200 0.8 1.1 6 46 ON 22.0 H 300 50 ON SR may be in error
20110408_175954 ??? 14.6 -2147483648 -2147483648 -1.00 -1.00 171410 3 66 200 0.8 1.1 6 43 ON 23.1 H 300 50 ON SR may be in error
20110408_180024 ??? 14.6 -2147483648 -2147483648 -1.00 -1.00 171410 3 66 200 0.8 1.1 6 43 ON 22.5 H 300 50 ON SR may be in error
20110408_180130 ??? 14.6 -2147483648 -2147483648 -1.00 -1.00 171410 3 66 200 0.8 1.1 6 40 ON 20.7 H 300 50 ON SR may be in error
20110408_180200 ??? 14.6 -2147483648 -2147483648 -1.00 -1.00 171410 3 66 200 0.8 1.1 6 41 ON 22.0 H 300 50 ON SR may be in error
20110408_180231 ??? 14.6 -2147483648 -2147483648 -1.00 -1.00 171410 3 66 200 0.8 1.1 6 42 ON 22.3 H 300 50 ON SR may be in error

-- EnricoPinna - 07 Apr 2011
bin1_mag9_6 = ['20110407_142718','20110407_143346','20110407_143428','20110407_144422','20110407_144459','20110407_144537','20110407_144659','20110407_144737','20110407_144815']  
bin1_mag10_1= ['20110407_150114','20110407_150603','20110407_150648','20110407_150814','20110407_150953']
bin1_mag10_7= ['20110408_161948','20110408_162026','20110408_162103','20110408_162225','20110408_162302','20110408_162340','20110408_162503','20110408_162540','20110408_162619','20110408_162741','20110408_162818','20110408_162856']
bin1_mag11_2= ['20110408_163954','20110408_164036','20110408_164118','20110408_164250','20110408_164334','20110408_164416','20110408_164533','20110408_164615','20110408_164657','20110408_164828','20110408_164910','20110408_164951']
flao2_bin1 = obj_new('aodataset',[bin1_mag9_6,bin1_mag10_1,bin1_mag10_7, bin1_mag11_2])
sr_b1 = flao2_bin1->value('irtc.sr_se')
mag_b1 = flao2_bin1->value('mag')



bin2_mag10_7= ['20110407_173951','20110407_174018','20110407_174150','20110407_174220']
bin2_mag11_0= ['20110407_174626','20110407_174653','20110407_174758','20110407_174825','20110407_174857']
bin2_mag11_8= ['20110407_180943','20110407_181011','20110407_181038','20110407_181143','20110407_181238','20110407_181358','20110407_181428','20110407_181532','20110407_181600','20110407_181627']
bin2_mag12_5= ['20110408_151120','20110408_151152','20110408_151225','20110408_151339','20110408_151412','20110408_151445','20110408_151608','20110408_151641','20110408_151714','20110408_151829','20110408_151902','20110408_151934']
bin2_mag13_5= ['20110408_155152','20110408_155219','20110408_155248','20110408_155352','20110408_155419','20110408_155447','20110408_155559','20110408_155627','20110408_155655','20110408_155800','20110408_155827']
flao2_bin2 = obj_new('aodataset',[bin2_mag10_7,bin2_mag11_0,bin2_mag11_8, bin2_mag12_5, bin2_mag13_5])
sr_b2 = flao2_bin2->value('irtc.sr_se')
mag_b2 = flao2_bin2->value('mag')

bin3_mag13_5= ['20110408_174641','20110408_174809','20110408_175424','20110408_175452']
flao2_bin3=obj_new('aodataset',[bin3_mag13_5])
sr_b3 = flao2_bin3->value('irtc.sr_se')
mag_b3 = flao2_bin3->value('mag')


; Simulation data (baseline and goal)
simul_table=fltarr(9,3)
simul_table[*,0]=[8.5,9.5,10.5,11.5,12.5,13.5,14.5,15.5,16.5]
simul_table[*,1]=[0.62,0.59,0.50,0.48,0.42,0.27,0.19,0.071,0.026]
simul_table[*,2]=[0.80,0.77,0.62,0.59,0.54,0.37,0.27,0.12,0.052]

plot, simul_table[*,0], simul_table[*,2], title='SR FLAO#2 @ tower testbench in April 2011', xtitle='R+I mag',ytitle='SR value (H band)', charsize=2, yrange=[0,1]
oplot, simul_table[*,0], simul_table[*,2],col='00ff00'x
oplot, simul_table[*,0], simul_table[*,1],col='0000ff'x
oplot, mag_b1, sr_b1, psym=4
oplot, mag_b2, sr_b2, psym=6
oplot, mag_b3, sr_b3, psym=5 

  • plottone-20110408.png:
    plottone-20110408.png
I Attachment Action Size Date Who Comment
plottone-20110408.pngpng plottone-20110408.png manage 111 K 08 Apr 2011 - 16:06 RunaBriguglio  
temp0.pngpng temp0.png manage 276 K 08 Apr 2011 - 12:34 UnknownUser  
temp1.pngpng temp1.png manage 94 K 08 Apr 2011 - 12:52 UnknownUser  
Topic revision: r12 - 15 Sep 2011, EnricoPinna
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding Foswiki? Send feedback