You are here: Foswiki>FLAO Web>TowerLab>LabTest20110215 (16 Feb 2011, EnricoPinna)Edit Attach
dopo l'intervento di Marco ieri sera oea l'OFFLOAD funziona

Test RON table con Lineare AGW#1 (no spare) attaccato direttamente alla linea 110V della torre (CEE giallo)


Observing status: OFF = flowerpot only (CCD47 integrating) STAGES ON!!!


SUMMARY ------------------------------------
Bin: 1 - Framerate 990 Hz (2500 kpix/sec) - RON (e-): 9.15 (estimated)
Bin: 2 - Framerate 990 Hz ( 800 kpix/sec) - RON (e-): 6.52 (estimated)
Bin: 2 - Framerate 625 Hz ( 380 kpix/sec) - RON (e-): 5.17 (estimated)
Bin: 2 - Framerate 400 Hz ( 380 kpix/sec) - RON (e-): 5.19 (estimated)
Bin: 3 - Framerate 200 Hz ( 380 kpix/sec) - RON (e-): 5.48 (estimated)
Bin: 4 - Framerate 300 Hz ( 335 kpix/sec) - RON (e-): 5.78 (estimated)
Bin: 4 - Framerate 200 Hz ( 335 kpix/sec) - RON (e-): 5.81 (estimated)
Bin: 4 - Framerate 105 Hz ( 335 kpix/sec) - RON (e-): 5.74 (estimated)


SUMMARY ------------------------------------
ccd39 - binning 1
Speed: 2500 kpix/sec - RON (ADU): 19.18 - RON (e-): 9.59 (estimated)
Speed: 890 kpix/sec - RON (ADU): 13.00 - RON (e-): 6.50 (estimated)
Speed: 400 kpix/sec - RON (ADU): 10.57 - RON (e-): 5.28 (estimated)


OFF = flowerpot + FW (CCD47 integrating) STAGES ON!!!


SUMMARY ------------------------------------
Bin: 1 - Framerate 990 Hz (2500 kpix/sec) - RON (e-): 9.01 (estimated)
Bin: 2 - Framerate 990 Hz ( 800 kpix/sec) - RON (e-): 6.42 (estimated)
Bin: 2 - Framerate 625 Hz ( 380 kpix/sec) - RON (e-): 5.37 (estimated)
Bin: 2 - Framerate 400 Hz ( 380 kpix/sec) - RON (e-): 5.08 (estimated)
Bin: 3 - Framerate 200 Hz ( 380 kpix/sec) - RON (e-): 5.41 (estimated)
Bin: 4 - Framerate 300 Hz ( 335 kpix/sec) - RON (e-): 5.53 (estimated)
Bin: 4 - Framerate 200 Hz ( 335 kpix/sec) - RON (e-): 5.80 (estimated)
Bin: 4 - Framerate 105 Hz ( 335 kpix/sec) - RON (e-): 5.66 (estimated)


SUMMARY ------------------------------------
ccd39 - binning 1
Speed: 2500 kpix/sec - RON (ADU): 18.93 - RON (e-): 9.46 (estimated)
Speed: 890 kpix/sec - RON (ADU): 12.99 - RON (e-): 6.50 (estimated)
Speed: 400 kpix/sec - RON (ADU): 10.21 - RON (e-): 5.10 (estimated)


OFF = flowerpot + FW + ADC (CCD47 integrating) STAGES ON!!!


SUMMARY ------------------------------------
Bin: 1 - Framerate 990 Hz (2500 kpix/sec) - RON (e-): 8.87 (estimated)
Bin: 2 - Framerate 990 Hz ( 800 kpix/sec) - RON (e-): 6.37 (estimated)
Bin: 2 - Framerate 625 Hz ( 380 kpix/sec) - RON (e-): 4.59 (estimated)
Bin: 2 - Framerate 400 Hz ( 380 kpix/sec) - RON (e-): 4.62 (estimated)
Bin: 3 - Framerate 200 Hz ( 380 kpix/sec) - RON (e-): 4.82 (estimated)
Bin: 4 - Framerate 300 Hz ( 335 kpix/sec) - RON (e-): 5.04 (estimated)
Bin: 4 - Framerate 200 Hz ( 335 kpix/sec) - RON (e-): 5.03 (estimated)
Bin: 4 - Framerate 105 Hz ( 335 kpix/sec) - RON (e-): 4.96 (estimated)


SUMMARY ------------------------------------
ccd39 - binning 1
Speed: 2500 kpix/sec - RON (ADU): 18.75 - RON (e-): 9.37 (estimated)
Speed: 890 kpix/sec - RON (ADU): 12.84 - RON (e-): 6.42 (estimated)
Speed: 400 kpix/sec - RON (ADU): 9.24 - RON (e-): 4.62 (estimated)


MI ACCORGO ORA DEGLI STAGES ON. Li disattivo.


OFF = flowerpot + FW + ADC (CCD47 integrating) + stages


SUMMARY ------------------------------------
Bin: 1 - Framerate 990 Hz (2500 kpix/sec) - RON (e-): 8.67 (estimated)
Bin: 2 - Framerate 990 Hz ( 800 kpix/sec) - RON (e-): 6.27 (estimated)
Bin: 2 - Framerate 625 Hz ( 380 kpix/sec) - RON (e-): 4.50 (estimated)
Bin: 2 - Framerate 400 Hz ( 380 kpix/sec) - RON (e-): 4.51 (estimated)
Bin: 3 - Framerate 200 Hz ( 380 kpix/sec) - RON (e-): 4.72 (estimated)
Bin: 4 - Framerate 300 Hz ( 335 kpix/sec) - RON (e-): 4.89 (estimated)
Bin: 4 - Framerate 200 Hz ( 335 kpix/sec) - RON (e-): 4.87 (estimated)
Bin: 4 - Framerate 105 Hz ( 335 kpix/sec) - RON (e-): 4.84 (estimated)


SUMMARY ------------------------------------
ccd39 - binning 1
Speed: 2500 kpix/sec - RON (ADU): 18.28 - RON (e-): 9.14 (estimated)
Speed: 890 kpix/sec - RON (ADU): 12.64 - RON (e-): 6.32 (estimated)
Speed: 400 kpix/sec - RON (ADU): 9.00 - RON (e-): 4.50 (estimated)


OFF = flowerpot + FW + ADC + Rirot (CCD47 integrating)+ stages


SUMMARY ------------------------------------
Bin: 1 - Framerate 990 Hz (2500 kpix/sec) - RON (e-): 8.71 (estimated)
Bin: 2 - Framerate 990 Hz ( 800 kpix/sec) - RON (e-): 6.22 (estimated)
Bin: 2 - Framerate 625 Hz ( 380 kpix/sec) - RON (e-): 4.05 (estimated)
Bin: 2 - Framerate 400 Hz ( 380 kpix/sec) - RON (e-): 4.04 (estimated)
Bin: 3 - Framerate 200 Hz ( 380 kpix/sec) - RON (e-): 4.16 (estimated)
Bin: 4 - Framerate 300 Hz ( 335 kpix/sec) - RON (e-): 4.29 (estimated)
Bin: 4 - Framerate 200 Hz ( 335 kpix/sec) - RON (e-): 4.33 (estimated)
Bin: 4 - Framerate 105 Hz ( 335 kpix/sec) - RON (e-): 4.43 (estimated)


SUMMARY ------------------------------------
ccd39 - binning 1
Speed: 2500 kpix/sec - RON (ADU): 18.32 - RON (e-): 9.16 (estimated)
Speed: 890 kpix/sec - RON (ADU): 12.62 - RON (e-): 6.31 (estimated)
Speed: 400 kpix/sec - RON (ADU): 8.22 - RON (e-): 4.11 (estimated)


OFF = flowerpot + FW + ADC + Rirot + LJ47+ stages


SUMMARY ------------------------------------
Bin: 1 - Framerate 990 Hz (2500 kpix/sec) - RON (e-): 8.66 (estimated)
Bin: 2 - Framerate 990 Hz ( 800 kpix/sec) - RON (e-): 6.22 (estimated)
Bin: 2 - Framerate 625 Hz ( 380 kpix/sec) - RON (e-): 4.06 (estimated)
Bin: 2 - Framerate 400 Hz ( 380 kpix/sec) - RON (e-): 4.07 (estimated)
Bin: 3 - Framerate 200 Hz ( 380 kpix/sec) - RON (e-): 4.19 (estimated)
Bin: 4 - Framerate 300 Hz ( 335 kpix/sec) - RON (e-): 4.33 (estimated)
Bin: 4 - Framerate 200 Hz ( 335 kpix/sec) - RON (e-): 4.38 (estimated)
Bin: 4 - Framerate 105 Hz ( 335 kpix/sec) - RON (e-): 4.44 (estimated)


SUMMARY ------------------------------------
ccd39 - binning 1
Speed: 2500 kpix/sec - RON (ADU): 18.27 - RON (e-): 9.14 (estimated)
Speed: 890 kpix/sec - RON (ADU): 12.58 - RON (e-): 6.29 (estimated)
Speed: 400 kpix/sec - RON (ADU): 8.26 - RON (e-): 4.13 (estimated)


Il CCD47 non sembra influenzare i RON delle velocita' piu' lente, quindi lo lascio spento


OFF = flowerpot + FW + ADC + LJ47+ stages


SUMMARY ------------------------------------
Bin: 1 - Framerate 990 Hz (2500 kpix/sec) - RON (e-): 8.68 (estimated)
Bin: 2 - Framerate 990 Hz ( 800 kpix/sec) - RON (e-): 6.26 (estimated)
Bin: 2 - Framerate 625 Hz ( 380 kpix/sec) - RON (e-): 4.49 (estimated)
Bin: 2 - Framerate 400 Hz ( 380 kpix/sec) - RON (e-): 4.50 (estimated)
Bin: 3 - Framerate 200 Hz ( 380 kpix/sec) - RON (e-): 4.76 (estimated)
Bin: 4 - Framerate 300 Hz ( 335 kpix/sec) - RON (e-): 4.91 (estimated)
Bin: 4 - Framerate 200 Hz ( 335 kpix/sec) - RON (e-): 4.96 (estimated)
Bin: 4 - Framerate 105 Hz ( 335 kpix/sec) - RON (e-): 4.91 (estimated)


SUMMARY ------------------------------------
ccd39 - binning 1
Speed: 2500 kpix/sec - RON (ADU): 18.32 - RON (e-): 9.16 (estimated)
Speed: 890 kpix/sec - RON (ADU): 12.69 - RON (e-): 6.35 (estimated)
Speed: 400 kpix/sec - RON (ADU): 9.18 - RON (e-): 4.59 (estimated)


OFF = flowerpot + FW + LJ47+ stages


SUMMARY ------------------------------------
Bin: 1 - Framerate 990 Hz (2500 kpix/sec) - RON (e-): 8.76 (estimated)
Bin: 2 - Framerate 990 Hz ( 800 kpix/sec) - RON (e-): 6.35 (estimated)
Bin: 2 - Framerate 625 Hz ( 380 kpix/sec) - RON (e-): 4.81 (estimated)
Bin: 2 - Framerate 400 Hz ( 380 kpix/sec) - RON (e-): 4.83 (estimated)
Bin: 3 - Framerate 200 Hz ( 380 kpix/sec) - RON (e-): 5.02 (estimated)
Bin: 4 - Framerate 300 Hz ( 335 kpix/sec) - RON (e-): 5.28 (estimated)
Bin: 4 - Framerate 200 Hz ( 335 kpix/sec) - RON (e-): 5.30 (estimated)
Bin: 4 - Framerate 105 Hz ( 335 kpix/sec) - RON (e-): 5.23 (estimated)


SUMMARY ------------------------------------
ccd39 - binning 1
Speed: 2500 kpix/sec - RON (ADU): 18.42 - RON (e-): 9.21 (estimated)
Speed: 890 kpix/sec - RON (ADU): 12.75 - RON (e-): 6.38 (estimated)
Speed: 400 kpix/sec - RON (ADU): 9.51 - RON (e-): 4.76 (estimated)


OFF = flowerpot + LJ47+ stages (OBSERVING CONDITIONS apart LJ47)


SUMMARY ------------------------------------
ccd39 - binning 1
Speed: 2500 kpix/sec - RON (ADU): 18.68 - RON (e-): 9.34 (estimated)
Speed: 890 kpix/sec - RON (ADU): 12.82 - RON (e-): 6.41 (estimated)
Speed: 400 kpix/sec - RON (ADU): 9.59 - RON (e-): 4.80 (estimated)


SUMMARY ------------------------------------
Bin: 1 - Framerate 990 Hz (2500 kpix/sec) - RON (e-): 8.84 (estimated)
Bin: 2 - Framerate 990 Hz ( 800 kpix/sec) - RON (e-): 6.32 (estimated)
Bin: 2 - Framerate 625 Hz ( 380 kpix/sec) - RON (e-): 4.74 (estimated)
Bin: 2 - Framerate 400 Hz ( 380 kpix/sec) - RON (e-): 4.76 (estimated)
Bin: 3 - Framerate 200 Hz ( 380 kpix/sec) - RON (e-): 5.05 (estimated)
Bin: 4 - Framerate 300 Hz ( 335 kpix/sec) - RON (e-): 5.24 (estimated)
Bin: 4 - Framerate 200 Hz ( 335 kpix/sec) - RON (e-): 5.34 (estimated)
Bin: 4 - Framerate 105 Hz ( 335 kpix/sec) - RON (e-): 5.29 (estimated)


SUMMARY ------------------------------------
ccd39 - binning 1
Speed: 2500 kpix/sec - RON (ADU): 18.62 - RON (e-): 9.31 (estimated)
Speed: 890 kpix/sec - RON (ADU): 12.76 - RON (e-): 6.38 (estimated)
Speed: 400 kpix/sec - RON (ADU): 9.56 - RON (e-): 4.78 (estimated)


OFF = LJ47+ stages + ADC + Rirot (TESTING CONDITION, lamp 100%, cube out of target)


SUMMARY ------------------------------------
Bin: 1 - Framerate 990 Hz (2500 kpix/sec) - RON (e-): 8.90 (estimated)
Bin: 2 - Framerate 990 Hz ( 800 kpix/sec) - RON (e-): 6.28 (estimated)
Bin: 2 - Framerate 625 Hz ( 380 kpix/sec) - RON (e-): 4.39 (estimated)
Bin: 2 - Framerate 400 Hz ( 380 kpix/sec) - RON (e-): 4.43 (estimated)
Bin: 3 - Framerate 200 Hz ( 380 kpix/sec) - RON (e-): 4.65 (estimated)
Bin: 4 - Framerate 300 Hz ( 335 kpix/sec) - RON (e-): 4.72 (estimated)
Bin: 4 - Framerate 200 Hz ( 335 kpix/sec) - RON (e-): 4.83 (estimated)
Bin: 4 - Framerate 105 Hz ( 335 kpix/sec) - RON (e-): 4.86 (estimated)


SUMMARY ------------------------------------
ccd39 - binning 1
Speed: 2500 kpix/sec - RON (ADU): 18.68 - RON (e-): 9.34 (estimated)
Speed: 890 kpix/sec - RON (ADU): 12.70 - RON (e-): 6.35 (estimated)
Speed: 400 kpix/sec - RON (ADU): 8.93 - RON (e-): 4.46 (estimated)


OFF = stages (lamp 100%, cube out of target)


SUMMARY ------------------------------------
Bin: 1 - Framerate 990 Hz (2500 kpix/sec) - RON (e-): 9.08 (estimated)
Bin: 2 - Framerate 990 Hz ( 800 kpix/sec) - RON (e-): 6.48 (estimated)
Bin: 2 - Framerate 625 Hz ( 380 kpix/sec) - RON (e-): 4.85 (estimated)
Bin: 2 - Framerate 400 Hz ( 380 kpix/sec) - RON (e-): 5.01 (estimated)
Bin: 3 - Framerate 200 Hz ( 380 kpix/sec) - RON (e-): 5.25 (estimated)
Bin: 4 - Framerate 300 Hz ( 335 kpix/sec) - RON (e-): 5.43 (estimated)
Bin: 4 - Framerate 200 Hz ( 335 kpix/sec) - RON (e-): 5.60 (estimated)
Bin: 4 - Framerate 105 Hz ( 335 kpix/sec) - RON (e-): 5.46 (estimated)


SUMMARY ------------------------------------
ccd39 - binning 1
Speed: 2500 kpix/sec - RON (ADU): 19.09 - RON (e-): 9.54 (estimated)
Speed: 890 kpix/sec - RON (ADU): 12.84 - RON (e-): 6.42 (estimated)
Speed: 400 kpix/sec - RON (ADU): 9.87 - RON (e-): 4.94 (estimated)




Riapplico il board setup torre

BIN 1

Non funziona lo scaricamento dei dati dalla IRTC.
Era giu' l'IRS su TCSTEST e poi e' finito lo spazio su aoserver.

Marco sposta un po' di roba su /towerdata/labot@aoserver

finalmente ripartiamo.

ricomincio con un loop senza disturbo bin1 400 modi max flux lamp

Pos=6 (no filter)
Lamp=255
No disturb

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph SR band exp #frames disturb notes
20110215_160055 ??? 8.7 -2147483648 -2147483648 -1.00 -1.00 143833 1 400 1000 0.2 0.3 3 208 74.6 H 70 200 OFF SR may be in error
20110215_160143 ??? 8.7 -2147483648 -2147483648 -1.00 -1.00 143833 1 400 1000 0.2 0.3 3 208 75.8 H 70 200 OFF SR may be in error
20110215_160232 ??? 8.7 -2147483648 -2147483648 -1.00 -1.00 143833 1 400 1000 0.2 0.3 3 209 81.9 H 70 200 OFF SR may be in error
20110215_160420 ??? 8.7 0 -2147483648 -1.00 -1.00 143833 1 400 1000 0.2 0.3 3 213 87.6 H 70 200 OFF SR may be in error
20110215_160516 ??? 8.7 -2147483648 -2147483648 -1.00 -1.00 143833 1 400 1000 0.2 0.3 3 211 87.8 H 70 200 OFF SR may be in error
20110215_160607 ??? 8.7 -2147483648 -2147483648 -1.00 -1.00 143833 1 400 1000 0.2 0.3 3 207 87.1 H 70 200 OFF SR may be in error
Abbasso la lampada e mettiamo il disturbo

Lamp = 190
Pos=6
TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph SR band exp #frames disturb notes
20110215_170425 ??? 9.3 -2147483648 -2147483648 -1.00 -1.00 143833 1 400 1000 0.4 0.4 3 116 68.1 H 100 200 ON  
20110215_170519 ??? 9.3 -2147483648 -2147483648 -1.00 -1.00 143833 1 400 1000 0.4 0.4 3 115 75.2 H 100 200 ON  
20110215_170614 ??? 9.3 -2147483648 -2147483648 -1.00 -1.00 143833 1 400 1000 0.4 0.4 3 116 79.7 H 100 200 ON  
20110215_170813 ??? 9.4 -2147483648 -2147483648 -1.00 -1.00 143833 1 400 1000 0.4 0.4 3 109 78.4 H 100 200 ON  
20110215_170908 ??? 9.3 -2147483648 -2147483648 -1.00 -1.00 143833 1 400 1000 0.4 0.4 3 114 70.5 H 100 200 ON  
20110215_171003 ??? 9.3 -2147483648 -2147483648 -1.00 -1.00 143833 1 400 1000 0.4 0.4 3 114 63.5 H 100 200 ON SR may be in error

bin1_novib=['20110209_120157','20110209_120244','20110209_120936','20110209_121024','20110209_121110']
TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph SR band exp #frames disturb notes
20110215_171231 ??? 9.5 -2147483648 -2147483648 -1.00 -1.00 143833 1 400 1000 0.4 0.4 3 97 -1.0 ? -1 -1 ON  
20110215_171326 ??? 9.5 -2147483648 -2147483648 -1.00 -1.00 143833 1 400 1000 0.4 0.4 3 98 83.8 H 100 200 ON SR may be in error
20110215_171421 ??? 9.5 -2147483648 -2147483648 -1.00 -1.00 143833 1 400 1000 0.4 0.4 3 98 81.2 H 100 200 ON  
20110215_171619 ??? 9.6 -2147483648 -2147483648 -1.00 -1.00 143833 1 400 1000 0.4 0.4 3 91 68.0 H 100 200 ON Background bombato
20110215_171717 ??? 9.5 -2147483648 -2147483648 -1.00 -1.00 143833 1 400 1000 0.4 0.4 3 97 67.9 H 100 200 ON SR may be in error
20110215_171811 ??? 9.5 -2147483648 -2147483648 -1.00 -1.00 143833 1 400 1000 0.4 0.4 3 97 72.6 H 100 200 ON  

-- EnricoPinna - 15 Feb 2011

bin1_mag093=['20110215_170425','20110215_170519','20110215_170614','20110215_170813','20110215_170908']

bin1_mag095=['20110215_171421']

bin2_mag087_1000=['20110210_153221','20110210_153318','20110210_153415','20110210_160508','20110210_160557','20110210_160703','20110210_160731',' 20110210_160758' ]

bin2_mag102_1000=['20110210_162018','20110210_162055','20110210_162133','20110210_162259','20110210_162337','20110210_162414','20110210_165959',' 20110210_170036']

bin2_mag110_1000=['20110211_105914','20110211_110009','20110211_110102','20110211_112827',' 20110211_112920','20110211_113014',' 20110211_113542','20110211_113636', '20110211_113730','20110211_115255','20110211_115617' ]

bin2_mag122_625=['20110211_162611','20110211_162738','20110211_162815','20110211_162853','20110211_163009','20110211_163047','20110211_163124','20110211_163251','20110211_163328','20110211_163406' ]

bin2_mag133_400=['20110211_164607','20110211_164632','20110211_164657','20110211_164759','20110211_164824','20110211_164848','20110211_165001','20110211_165026','20110211_165050','20110211_165152','20110211_165217','20110211_165241']

bin3_novib=['20110209_160718',' 20110209_160747','20110209_160815','20110209_160925','20110209_160954',' 20110209_161022','20110209_163005','20110209_163034','20110209_163102','20110209_163211','20110209_163239','20110209_163308']

bin3_mag147=['20110209_164223','20110209_164251','20110209_164320','20110209_164423','20110209_164452','20110209_164520']

bin3_mag151=['20110209_173936','20110209_174004','20110209_174033 ','20110209_174138','20110209_174206','20110209_174234']

bin4_mag142=['20110210_120500','20110210_120534','20110210_120608','20110210_120724','20110210_120758','20110210_120832']

bin4_mag150=['20110210_122620','20110210_122653','20110210_122726','20110210_122835','20110210_122908','20110210_122942']

bin4_mag158=['20110210_125748','20110210_130515','20110210_125821','20110210_125854' ]

bin4_mag163=['20110210_133237','20110210_133330','20110210_133422','20110210_133552','20110210_133644' ]

flao2_bin1 = obj_new('aodataset',[bin1_novib, bin1_mag093,bin1_mag095 ] )

flao2_bin2 = obj_new('aodataset',[bin2_mag087_1000, bin2_mag102_1000, bin2_mag110_1000, bin2_mag122_625, bin2_mag133_400] )

flao2_bin3 = obj_new('aodataset',[bin3_novib, bin3_mag147, bin3_mag151] )

flao2_bin4 = obj_new('aodataset',[bin4_mag142,bin4_mag150,bin4_mag158,bin4_mag163] )

sr_b1 = flao2_bin1->value('irtc.sr_se')

sr_b2 = flao2_bin2->value('irtc.sr_se')

sr_b3 = flao2_bin3->value('irtc.sr_se')

sr_b4 = flao2_bin4->value('irtc.sr_se')

mag_b1 = flao2_bin1->value('mag')

mag_b2 = flao2_bin2->value('mag')

mag_b3 = flao2_bin3->value('mag')

mag_b4 = flao2_bin4->value('mag')

simul_table=fltarr(9,3)

simul_table[*,0]=[8.5,9.5,10.5,11.5,12.5,13.5,14.5,15.5,16.5]

simul_table[*,1]=[0.62,0.59,0.50,0.48,0.42,0.27,0.19,0.071,0.026]

simul_table[*,2]=[0.80,0.77,0.62,0.59,0.54,0.37,0.27,0.12,0.052]

plot, simul_table[*,0], simul_table[*,2], title='SR FLAO#2 @ tower testbench', xtitle='R+I mag',ytitle='SR value (H band)', charsize=2, yrange=[0,1]

oplot, simul_table[*,0], simul_table[*,2],col='00ff00'x

oplot, simul_table[*,0], simul_table[*,1],col='0000ff'x

oplot, mag_b1, sr_b1, psym=4

oplot, mag_b2, sr_b2, psym=6

oplot, mag_b3, sr_b3, psym=5

oplot, mag_b4, sr_b4, psym=2
Topic revision: r4 - 16 Feb 2011, EnricoPinna
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding Foswiki? Send feedback