You are here: Foswiki>FLAO Web>TowerLab>LabTest20110211 (11 Feb 2011, EnricoPinna)Edit Attach

Bin 2

Pos=1

Lamp=255

Antidrift = ON

OFF= LJ47, FW, ADC, Pup rot
TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph SR band exp #frames disturb notes
20110211_105555 ??? 11.0 -2147483648 -2147483648 -1.00 -1.00 151228 2 153 991 0.3 0.4 3 101 61.9 H 100 200 ON SR may be in error
20110211_105648 ??? 11.0 -2147483648 -2147483648 -1.00 -1.00 151228 2 153 991 0.3 0.4 3 98 62.5 H 100 200 ON SR may be in error
20110211_105742 ??? 11.0 -2147483648 -2147483648 -1.00 -1.00 151228 2 153 991 0.3 0.4 3 99 61.0 H 100 200 ON SR may be in error
20110211_105914 ??? 11.0 -2147483648 -2147483648 -1.00 -1.00 151228 2 153 991 0.3 0.4 3 100 49.1 H 100 200 ON  
20110211_110009 ??? 10.9 -2147483648 -2147483648 -1.00 -1.00 151228 2 153 991 0.3 0.4 3 105 50.0 H 100 200 ON  
20110211_110102 ??? 11.0 -2147483648 -2147483648 -1.00 -1.00 151228 2 153 991 0.3 0.4 3 103 52.5 H 100 200 ON  
20110211_110452 ??? 11.0 -2147483648 -2147483648 -1.00 -1.00 151228 2 153 991 0.3 0.4 3 101 61.8 H 100 200 ON SR may be in error
20110211_110547 ??? 11.0 -2147483648 -2147483648 -1.00 -1.00 151228 2 153 991 0.3 0.4 3 100 60.9 H 100 200 ON SR may be in error
20110211_110640 ??? 11.0 -2147483648 -2147483648 -1.00 -1.00 151228 2 153 991 0.3 0.4 3 100 56.6 H 100 200 ON SR may be in error
20110211_110813 ??? 10.9 -2147483648 -2147483648 -1.00 -1.00 151228 2 153 991 0.3 0.4 3 107 53.6 H 100 200 ON SR may be in error
20110211_110908 ??? 11.0 -2147483648 -2147483648 -1.00 -1.00 151228 2 153 991 0.3 0.4 3 102 56.1 H 100 200 ON SR may be in error
20110211_111002 ??? 11.0 -2147483648 -2147483648 -1.00 -1.00 151228 2 153 991 0.3 0.4 3 103 57.1 H 100 200 ON SR may be in error
20110211_111406 ??? 11.0 -2147483648 -2147483648 -1.00 -1.00 151228 2 153 991 0.3 0.4 3 103 -1.0 ? -1 -1 ON  
20110211_111427 ??? 11.0 -2147483648 -2147483648 -1.00 -1.00 151228 2 153 991 0.3 0.4 3 104 45.4 H 100 200 ON  
20110211_111520 ??? 10.9 -2147483648 -2147483648 -1.00 -1.00 151228 2 153 991 0.3 0.4 3 105 45.4 H 100 200 ON  
20110211_111614 ??? 11.0 -2147483648 -2147483648 -1.00 -1.00 151228 2 153 991 0.3 0.4 3 101 47.7 H 100 200 ON  
20110211_111746 ??? 10.9 -2147483648 -2147483648 -1.00 -1.00 151228 2 153 991 0.3 0.4 3 105 -1.0 ? -1 -1 ON  
20110211_111807 ??? 11.0 -2147483648 -2147483648 -1.00 -1.00 151228 2 153 991 0.3 0.4 3 103 52.4 H 100 200 ON SR may be in error
20110211_111901 ??? 11.0 -2147483648 -2147483648 -1.00 -1.00 151228 2 153 991 0.3 0.4 3 102 53.4 H 100 200 ON SR may be in error

Le performance sembrano in decrescita, FACCIAMO un LAODSHAPE
TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph SR band exp #frames disturb notes
20110211_112827 ??? 11.0 -2147483648 -2147483648 -1.00 -1.00 151228 2 153 991 0.3 0.4 3 103 57.7 H 100 200 ON  
20110211_112920 ??? 10.9 -2147483648 -2147483648 -1.00 -1.00 151228 2 153 991 0.3 0.4 3 105 49.3 H 100 200 ON  
20110211_113014 ??? 10.9 -2147483648 -2147483648 -1.00 -1.00 151228 2 153 991 0.3 0.4 3 107 51.4 H 100 200 ON  
20110211_113147 ??? 11.0 -2147483648 -2147483648 -1.00 -1.00 151228 2 153 991 0.3 0.4 3 104 57.5 H 100 200 ON SR may be in error
20110211_113240 ??? 11.0 -2147483648 -2147483648 -1.00 -1.00 151228 2 153 991 0.3 0.4 3 104 59.0 H 100 200 ON SR may be in error
20110211_113334 ??? 10.9 -2147483648 -2147483648 -1.00 -1.00 151228 2 153 991 0.3 0.4 3 104 58.5 H 100 200 ON SR may be in error
20110211_113542 ??? 10.9 -2147483648 -2147483648 -1.00 -1.00 151228 2 153 991 0.3 0.4 3 108 54.5 H 100 200 ON  
20110211_113636 ??? 11.0 -2147483648 -2147483648 -1.00 -1.00 151228 2 153 991 0.3 0.4 3 103 47.8 H 100 200 ON  
20110211_113730 ??? 10.9 -2147483648 -2147483648 -1.00 -1.00 151228 2 153 991 0.3 0.4 3 106 49.1 H 100 200 ON  
20110211_113902 ??? 10.9 -2147483648 -2147483648 -1.00 -1.00 151228 2 153 991 0.3 0.4 3 105 57.8 H 100 200 ON SR may be in error
20110211_113956 ??? 10.9 -2147483648 -2147483648 -1.00 -1.00 151228 2 153 991 0.3 0.4 3 106 60.5 H 100 200 ON SR may be in error
20110211_114050 ??? 10.9 -2147483648 -2147483648 -1.00 -1.00 151228 2 153 991 0.3 0.4 3 106 59.2 H 100 200 ON SR may be in error
20110211_114554 ??? 10.9 -2147483648 -2147483648 -1.00 -1.00 151228 2 153 991 0.3 0.4 3 104 -1.0 ? -1 -1 ON  
20110211_114615 ??? 10.9 -2147483648 -2147483648 -1.00 -1.00 151228 2 153 991 0.3 0.4 3 107 48.1 H 100 200 ON  
20110211_114708 ??? 10.9 -2147483648 -2147483648 -1.00 -1.00 151228 2 153 991 0.3 0.4 3 106 51.1 H 100 200 ON  
20110211_114841 ??? 10.9 -2147483648 -2147483648 -1.00 -1.00 151228 2 153 991 0.3 0.4 3 106 49.9 H 100 200 ON  
20110211_114934 ??? 10.9 -2147483648 -2147483648 -1.00 -1.00 151228 2 153 991 0.3 0.4 3 106 42.1 H 100 200 ON  
20110211_115028 ??? 10.9 -2147483648 -2147483648 -1.00 -1.00 151228 2 153 991 0.3 0.4 3 105 42.3 H 100 200 ON  

Rifacciamo il load shape
TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph SR band exp #frames disturb notes
20110211_115255 ??? 10.9 -2147483648 -2147483648 -1.00 -1.00 151228 2 153 991 0.3 0.4 3 105 54.8 H 100 200 ON  
20110211_115349 ??? 10.9 -2147483648 -2147483648 -1.00 -1.00 151228 2 153 991 0.3 0.4 3 106 59.8 H 100 200 ON SR may be in error
20110211_115443 ??? 10.9 -2147483648 -2147483648 -1.00 -1.00 151228 2 153 991 0.3 0.4 3 106 58.8 H 100 200 ON SR may be in error
20110211_115617 ??? 10.9 -2147483648 -2147483648 -1.00 -1.00 151228 2 153 991 0.3 0.4 3 110 52.6 H 100 200 ON  
20110211_115711 ??? 10.9 -2147483648 -2147483648 -1.00 -1.00 151228 2 153 991 0.3 0.4 3 106 45.7 H 100 200 ON  
20110211_115804 ??? 10.9 -2147483648 -2147483648 -1.00 -1.00 151228 2 153 991 0.3 0.4 3 107 46.6 H 100 200 ON  

Ora rallentiamo il CCD per andare alle velocita' da tabella

Pos=1

Lamp=255

Antidrift = ON

OFF= LJ47, FW, ADC, Pup rot

Sweep gain

Riapplichiamo il load shape
TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph SR band exp #frames disturb notes
20110211_121257 ??? 10.9 -2147483648 -2147483648 -1.00 -1.00 151228 2 153 801 0.5 0.6 3 130 46.1 H 100 200 ON  
20110211_121350 ??? 11.0 -2147483648 -2147483648 -1.00 -1.00 151228 2 153 801 0.5 0.6 3 129 49.0 H 100 200 ON  
20110211_121444 ??? 11.0 -2147483648 -2147483648 -1.00 -1.00 151228 2 153 801 0.5 0.6 3 129 49.0 H 100 200 ON  
20110211_121616 ??? 10.9 -2147483648 -2147483648 -1.00 -1.00 151228 2 153 801 0.5 0.6 3 131 49.5 H 100 200 ON  
20110211_121710 ??? 10.9 -2147483648 -2147483648 -1.00 -1.00 151228 2 153 801 0.5 0.6 3 130 42.7 H 100 200 ON  
20110211_121804 ??? 10.9 -2147483648 -2147483648 -1.00 -1.00 151228 2 153 801 0.5 0.6 3 130 42.8 H 100 200 ON  

Abbassiamo la lampada

Pos=1

Lamp= 199

Antidrift = ON

OFF= LJ47, FW, ADC, Pup rot

Sweep gain
TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph SR band exp #frames disturb notes
20110211_122504 ??? 11.1 -2147483648 -2147483648 -1.00 -1.00 151228 2 153 801 0.5 0.6 3 108 46.6 H 150 100 ON  
20110211_122537 ??? 11.2 -2147483648 -2147483648 -1.00 -1.00 151228 2 153 801 0.5 0.6 3 107 48.4 H 150 100 ON  
20110211_122609 ??? 11.1 -2147483648 -2147483648 -1.00 -1.00 151228 2 153 801 0.5 0.6 3 108 46.9 H 150 100 ON  
20110211_122726 ??? 11.2 -2147483648 -2147483648 -1.00 -1.00 151228 2 153 801 0.5 0.6 3 102 51.5 H 150 100 ON SR may be in error
20110211_122758 ??? 11.1 -2147483648 -2147483648 -1.00 -1.00 151228 2 153 801 0.5 0.6 3 110 51.3 H 150 100 ON SR may be in error
20110211_122830 ??? 11.2 -2147483648 -2147483648 -1.00 -1.00 151228 2 153 801 0.5 0.6 3 105 48.9 H 150 100 ON SR may be in error

Abbassiamo ancora

Lamp =192
TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph SR band exp #frames disturb notes
20110211_123843 ??? 11.6 -2147483648 -2147483648 -1.00 -1.00 151228 2 153 801 0.4 0.7 3 72 50.4 H 150 100 ON SR may be in error
20110211_123916 ??? 11.7 -2147483648 -2147483648 -1.00 -1.00 151228 2 153 801 0.4 0.7 3 65 46.0 H 150 100 ON  
20110211_123948 ??? 11.7 -2147483648 -2147483648 -1.00 -1.00 151228 2 153 801 0.4 0.7 3 67 46.4 H 150 100 ON  
20110211_124104 ??? 11.7 -2147483648 -2147483648 -1.00 -1.00 151228 2 153 801 0.4 0.7 3 64 48.3 H 150 100 ON SR may be in error
20110211_124137 ??? 11.6 -2147483648 -2147483648 -1.00 -1.00 151228 2 153 801 0.4 0.7 3 68 -1.0 ? -1 -1 ON  
20110211_124156 ??? 11.6 -2147483648 -2147483648 -1.00 -1.00 151228 2 153 801 0.4 0.7 3 70 52.0 H 150 100 ON SR may be in error
20110211_124530 ??? 11.7 -2147483648 -2147483648 -1.00 -1.00 151228 2 153 801 0.4 0.7 3 67 58.1 H 150 100 ON SR may be in error
20110211_124602 ??? 11.6 -2147483648 -2147483648 -1.00 -1.00 151228 2 153 801 0.4 0.7 3 68 55.4 H 150 100 ON SR may be in error
20110211_124635 ??? 11.6 -2147483648 -2147483648 -1.00 -1.00 151228 2 153 801 0.4 0.7 3 69 48.0 H 150 100 ON SR may be in error
20110211_124751 ??? 11.7 -2147483648 -2147483648 -1.00 -1.00 151228 2 153 801 0.4 0.7 3 67 51.3 H 150 100 ON SR may be in error
20110211_124823 ??? 11.6 -2147483648 -2147483648 -1.00 -1.00 151228 2 153 801 0.4 0.7 3 68 53.9 H 150 100 ON SR may be in error
20110211_124856 ??? 11.6 -2147483648 -2147483648 -1.00 -1.00 151228 2 153 801 0.4 0.7 3 69 55.6 H 150 100 ON SR may be in error
Non se ne salva piu' nessuno. Alziamo il set point della camera a 249, ovvero ad una tempo che possa ragigungere.

SR ESPOSITO MODIFICATA

Implementato il FIX BACKGROUND (/FIX_BG per log_twiki)
qusto regola il background dell'immagine IRTC aggiungendo o sottraendo una costante in modo che lontano della psf il contributo al flusso sia nullo.

Tolta la procedura di riduzione di righe di Carmelo perche' a volte prduceva una buca intorno alla PSF (sopra e sotto) e rendeva impossibile la stima dello SR


RON TEST versione vecchia

OFF: LJ47 + ADC + Pupil rerotator


SUMMARY ------------------------------------
ccd39 - binning 1
Speed: 2500 kpix/sec - RON (ADU): 18.30 - RON (e-): 9.15 (estimated)
Speed: 890 kpix/sec - RON (ADU): 13.06 - RON (e-): 6.53 (estimated)
Speed: 400 kpix/sec - RON (ADU): 9.62 - RON (e-): 4.81 (estimated)

OFF: LJ47 + ADC + FW + Pupil rerotator


SUMMARY ------------------------------------
ccd39 - binning 1
Speed: 2500 kpix/sec - RON (ADU): 18.00 - RON (e-): 9.00 (estimated)
Speed: 890 kpix/sec - RON (ADU): 12.89 - RON (e-): 6.44 (estimated)
Speed: 400 kpix/sec - RON (ADU): 8.93 - RON (e-): 4.47 (estimated)

OFF: LJ47


SUMMARY ------------------------------------
ccd39 - binning 1
Speed: 2500 kpix/sec - RON (ADU): 18.45 - RON (e-): 9.22 (estimated)
Speed: 890 kpix/sec - RON (ADU): 13.23 - RON (e-): 6.62 (estimated)
Speed: 400 kpix/sec - RON (ADU): 10.60 - RON (e-): 5.30 (estimated)


Bin 2 ancora

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph SR band exp #frames disturb notes
20110211_161302 ??? 12.2 -2147483648 -2147483648 -1.00 -1.00 151228 2 153 625 0.4 0.7 3 52 43.0 H 200 100 ON - oversampling freq not a multiple of loop freqSR may be in error
20110211_161339 ??? 12.2 -2147483648 -2147483648 -1.00 -1.00 151228 2 153 625 0.4 0.7 3 51 45.4 H 200 100 ON - oversampling freq not a multiple of loop freqSR may be in error
20110211_161417 ??? 12.2 -2147483648 -2147483648 -1.00 -1.00 151228 2 153 625 0.4 0.7 3 50 46.1 H 200 100 ON - oversampling freq not a multiple of loop freqSR may be in error
20110211_161543 ??? 12.3 -2147483648 -2147483648 -1.00 -1.00 151228 2 153 625 0.4 0.7 3 49 42.1 H 200 100 ON - oversampling freq not a multiple of loop freq
20110211_161621 ??? 12.3 -2147483648 -2147483648 -1.00 -1.00 151228 2 153 625 0.4 0.7 3 49 44.3 H 200 100 ON - oversampling freq not a multiple of loop freqSR may be in error
20110211_161658 ??? 12.2 -2147483648 -2147483648 -1.00 -1.00 151228 2 153 625 0.4 0.7 3 50 43.9 H 200 100 ON - oversampling freq not a multiple of loop freq
20110211_161851 ??? 12.2 -2147483648 -2147483648 -1.00 -1.00 151228 2 153 625 0.4 0.7 3 51 38.8 H 200 100 ON - oversampling freq not a multiple of loop freqSR may be in error
20110211_161929 ??? 12.2 -2147483648 -2147483648 -1.00 -1.00 151228 2 153 625 0.4 0.7 3 51 39.6 H 200 100 ON - oversampling freq not a multiple of loop freqSR may be in error
20110211_162006 ??? 12.2 -2147483648 -2147483648 -1.00 -1.00 151228 2 153 625 0.4 0.7 3 52 38.5 H 200 100 ON - oversampling freq not a multiple of loop freq
20110211_162133 ??? 12.3 -2147483648 -2147483648 -1.00 -1.00 151228 2 153 625 0.4 0.7 3 49 43.7 H 200 100 ON - oversampling freq not a multiple of loop freq
20110211_162211 ??? 12.2 -2147483648 -2147483648 -1.00 -1.00 151228 2 153 625 0.4 0.7 3 50 43.7 H 200 100 ON - oversampling freq not a multiple of loop freq
20110211_162248 ??? 12.2 -2147483648 -2147483648 -1.00 -1.00 151228 2 153 625 0.4 0.7 3 50 40.8 H 200 100 ON - oversampling freq not a multiple of loop freq
20110211_162456 ??? 12.2 -2147483648 -2147483648 -1.00 -1.00 151228 2 153 625 0.4 0.7 3 53 40.5 H 200 100 ON - oversampling freq not a multiple of loop freq
20110211_162534 ??? 12.2 -2147483648 -2147483648 -1.00 -1.00 151228 2 153 625 0.4 0.7 3 51 0.0 H 200 100 ON - oversampling freq not a multiple of loop freqBackground correction failed
20110211_162611 ??? 12.2 -2147483648 -2147483648 -1.00 -1.00 151228 2 153 625 0.4 0.7 3 52 42.4 H 200 100 ON - oversampling freq not a multiple of loop freq
20110211_162738 ??? 12.3 -2147483648 -2147483648 -1.00 -1.00 151228 2 153 625 0.4 0.7 3 49 45.4 H 200 100 ON - oversampling freq not a multiple of loop freq
20110211_162815 ??? 12.2 -2147483648 -2147483648 -1.00 -1.00 151228 2 153 625 0.4 0.7 3 51 46.6 H 200 100 ON - oversampling freq not a multiple of loop freq
20110211_162853 ??? 12.2 -2147483648 -2147483648 -1.00 -1.00 151228 2 153 625 0.4 0.7 3 53 45.9 H 200 100 ON - oversampling freq not a multiple of loop freq
20110211_163009 ??? 12.2 -2147483648 -2147483648 -1.00 -1.00 151228 2 153 625 0.4 0.7 3 50 47.8 H 200 100 ON - oversampling freq not a multiple of loop freq
20110211_163047 ??? 12.2 -2147483648 -2147483648 -1.00 -1.00 151228 2 153 625 0.4 0.7 3 53 45.7 H 200 100 ON - oversampling freq not a multiple of loop freq
20110211_163124 ??? 12.2 -2147483648 -2147483648 -1.00 -1.00 151228 2 153 625 0.4 0.7 3 52 45.1 H 200 100 ON - oversampling freq not a multiple of loop freq
20110211_163251 ??? 12.3 -2147483648 -2147483648 -1.00 -1.00 151228 2 153 625 0.4 0.7 3 47 40.8 H 200 100 ON - oversampling freq not a multiple of loop freq
20110211_163328 ??? 12.2 -2147483648 -2147483648 -1.00 -1.00 151228 2 153 625 0.4 0.7 3 54 42.6 H 200 100 ON - long stop of 61 frames at frame 1191 - oversampling freq not a multiple of loop freq
20110211_163406 ??? 12.2 -2147483648 -2147483648 -1.00 -1.00 151228 2 153 625 0.4 0.7 3 54 43.9 H 200 100 ON - oversampling freq not a multiple of loop freq
Abbassiamo la lampada Lamp=180 Pos=1

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph SR band exp #frames disturb notes
20110211_164607 ??? 13.3 -2147483648 -2147483648 -1.00 -1.00 151228 2 153 400 0.4 0.7 3 30 27.2 H 300 50 ON  
20110211_164632 ??? 13.3 -2147483648 -2147483648 -1.00 -1.00 151228 2 153 400 0.4 0.7 3 30 26.2 H 300 50 ON  
20110211_164657 ??? 13.2 -2147483648 -2147483648 -1.00 -1.00 151228 2 153 400 0.4 0.7 3 31 24.2 H 300 50 ON  
20110211_164759 ??? 13.3 -2147483648 -2147483648 -1.00 -1.00 151228 2 153 400 0.4 0.7 3 29 25.5 H 300 50 ON  
20110211_164824 ??? 13.2 -2147483648 -2147483648 -1.00 -1.00 151228 2 153 400 0.4 0.7 3 31 25.6 H 300 50 ON  
20110211_164848 ??? 13.2 -2147483648 -2147483648 -1.00 -1.00 151228 2 153 400 0.4 0.7 3 32 26.6 H 300 50 ON  
20110211_165001 ??? 13.2 -2147483648 -2147483648 -1.00 -1.00 151228 2 153 400 0.4 0.7 3 34 22.8 H 300 50 ON SR may be in error
20110211_165026 ??? 13.2 -2147483648 -2147483648 -1.00 -1.00 151228 2 153 400 0.4 0.7 3 33 24.1 H 300 50 ON  
20110211_165050 ??? 13.3 -2147483648 -2147483648 -1.00 -1.00 151228 2 153 400 0.4 0.7 3 29 27.3 H 300 50 ON  
20110211_165152 ??? 13.5 -2147483648 -2147483648 -1.00 -1.00 151228 2 153 400 0.4 0.7 3 25 24.1 H 300 50 ON  
20110211_165217 ??? 13.3 -2147483648 -2147483648 -1.00 -1.00 151228 2 153 400 0.4 0.7 3 30 25.1 H 300 50 ON SR may be in error
20110211_165241 ??? 13.2 -2147483648 -2147483648 -1.00 -1.00 151228 2 153 400 0.4 0.7 3 32 24.0 H 300 50 ON SR may be in error

Aggiustiamo il gain a manina
TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph SR band exp #frames disturb notes
20110211_165357 ??? 13.2 -2147483648 -2147483648 -1.00 -1.00 151228 2 153 400 0.5 0.8 3 32 25.2 H 300 50 ON  
20110211_165422 ??? 13.3 -2147483648 -2147483648 -1.00 -1.00 151228 2 153 400 0.5 0.8 3 29 23.8 H 300 50 ON SR may be in error
20110211_165446 ??? 13.2 -2147483648 -2147483648 -1.00 -1.00 151228 2 153 400 0.5 0.8 3 32 24.8 H 300 50 ON  
20110211_165548 ??? 13.3 -2147483648 -2147483648 -1.00 -1.00 151228 2 153 400 0.5 0.8 3 31 23.2 H 300 50 ON SR may be in error
20110211_165612 ??? 13.3 -2147483648 -2147483648 -1.00 -1.00 151228 2 153 400 0.5 0.8 3 29 25.4 H 300 50 ON  
20110211_165636 ??? 13.3 -2147483648 -2147483648 -1.00 -1.00 151228 2 153 400 0.5 0.8 3 30 25.9 H 300 50 ON  
Facciamo un loadshape

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph SR band exp #frames disturb notes
20110211_165759 ??? 13.4 -2147483648 -2147483648 -1.00 -1.00 151228 2 153 400 0.4 0.7 3 28 25.7 H 300 50 ON  
20110211_165823 ??? 13.3 -2147483648 -2147483648 -1.00 -1.00 151228 2 153 400 0.4 0.7 3 30 24.9 H 300 50 ON  
20110211_165847 ??? 13.2 -2147483648 -2147483648 -1.00 -1.00 151228 2 153 400 0.4 0.7 3 32 25.3 H 300 50 ON  
20110211_165950 ??? 13.4 -2147483648 -2147483648 -1.00 -1.00 151228 2 153 400 0.4 0.7 3 27 23.4 H 300 50 ON  
20110211_170014 ??? 13.2 -2147483648 -2147483648 -1.00 -1.00 151228 2 153 400 0.4 0.7 3 32 21.3 H 300 50 ON  
20110211_170039 ??? 13.2 -2147483648 -2147483648 -1.00 -1.00 151228 2 153 400 0.4 0.7 3 32 20.7 H 300 50 ON  



bin1_novib=['20110209_120157','20110209_120244','20110209_120936','20110209_121024','20110209_121110']

bin2_mag087_1000=['20110210_153221','20110210_153318','20110210_153415','20110210_160508','20110210_160557','20110210_160703','20110210_160731',' 20110210_160758' ]

bin2_mag102_1000=['20110210_162018','20110210_162055','20110210_162133','20110210_162259','20110210_162337','20110210_162414','20110210_165959',' 20110210_170036']

bin2_mag110_1000=['20110211_105914','20110211_110009','20110211_110102','20110211_112827',' 20110211_112920','20110211_113014',' 20110211_113542','20110211_113636', '20110211_113730','20110211_115255','20110211_115617' ]

bin2_mag122_625=['20110211_162611','20110211_162738','20110211_162815','20110211_162853','20110211_163009','20110211_163047','20110211_163124','20110211_163251','20110211_163328','20110211_163406' ]

bin2_mag133_400=['20110211_164607','20110211_164632','20110211_164657','20110211_164759','20110211_164824','20110211_164848','20110211_165001','20110211_165026','20110211_165050','20110211_165152','20110211_165217','20110211_165241']

bin3_novib=['20110209_160718',' 20110209_160747','20110209_160815','20110209_160925','20110209_160954',' 20110209_161022','20110209_163005','20110209_163034','20110209_163102','20110209_163211','20110209_163239','20110209_163308']

bin3_mag147=['20110209_164223','20110209_164251','20110209_164320','20110209_164423','20110209_164452','20110209_164520']

bin3_mag151=['20110209_173936','20110209_174004','20110209_174033 ','20110209_174138','20110209_174206','20110209_174234']

bin4_mag142=['20110210_120500','20110210_120534','20110210_120608','20110210_120724','20110210_120758','20110210_120832']

bin4_mag150=['20110210_122620','20110210_122653','20110210_122726','20110210_122835','20110210_122908','20110210_122942']

bin4_mag158=['20110210_125748','20110210_130515','20110210_125821','20110210_125854' ]

bin4_mag163=['20110210_133237','20110210_133330','20110210_133422','20110210_133552','20110210_133644' ]

flao2_bin1 = obj_new('aodataset',[bin1_novib] )

flao2_bin2 = obj_new('aodataset',[bin2_mag087_1000, bin2_mag102_1000, bin2_mag110_1000, bin2_mag122_625, bin2_mag133_400] )

flao2_bin3 = obj_new('aodataset',[bin3_novib, bin3_mag147, bin3_mag151] )

flao2_bin4 = obj_new('aodataset',[bin4_mag142,bin4_mag150,bin4_mag158,bin4_mag163] )

sr_b1 = flao2_bin1->value('irtc.sr_se')

sr_b2 = flao2_bin2->value('irtc.sr_se')

sr_b3 = flao2_bin3->value('irtc.sr_se')

sr_b4 = flao2_bin4->value('irtc.sr_se')

mag_b1 = flao2_bin1->value('mag')

mag_b2 = flao2_bin2->value('mag')

mag_b3 = flao2_bin3->value('mag')

mag_b4 = flao2_bin4->value('mag')

simul_table=fltarr(9,3)

simul_table[*,0]=[8.5,9.5,10.5,11.5,12.5,13.5,14.5,15.5,16.5]

simul_table[*,1]=[0.62,0.59,0.50,0.48,0.42,0.27,0.19,0.071,0.026]

simul_table[*,2]=[0.80,0.77,0.62,0.59,0.54,0.37,0.27,0.12,0.052]

plot, simul_table[*,0], simul_table[*,2], title='SR FLAO#2 @ tower testbench', xtitle='R+I mag',ytitle='SR value (H band)', charsize=2, yrange=[0,1]

oplot, simul_table[*,0], simul_table[*,2],col='00ff00'x

oplot, simul_table[*,0], simul_table[*,1],col='0000ff'x

oplot, mag_b1, sr_b1, psym=4

oplot, mag_b2, sr_b2, psym=6

oplot, mag_b3, sr_b3, psym=5

oplot, mag_b4, sr_b4, psym=2

  • plottone_20110211.png:
    plottone_20110211.png
Topic revision: r4 - 11 Feb 2011, EnricoPinna
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.