You are here: Foswiki>FLAO Web>TowerLab>LabTest20110210 (11 Feb 2011, EnricoPinna)Edit Attach

Problema di vignetting... finto!

Sulla IRTC arriva la luce ma sul WFS solo uno strano spicchio.

Alla fine ci accorgiamo che stavamo centrando sullo spot di sinistra perche' nella IRTC vedevamo uno spot, ma era quello SBAGLIATO!!!



Misure a BIN4 seeing 0.8"

Pos = 3
Lamop 100% (255)
Antidrift ON

Gain con autogain -0.1 di TT

OFF: LJ47 + stages (z active) + ADC + FW + Rirot
TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph SR band exp #frames disturb notes
20110210_120500 ??? 14.2 -2147483648 -2147483648 -1.00 -1.00 112130 4 36 200 1.0 1.1 6 108 14.2 H 400 50 ON  
20110210_120534 ??? 14.2 -2147483648 -2147483648 -1.00 -1.00 112130 4 36 200 1.0 1.1 6 108 14.6 H 400 50 ON  
20110210_120608 ??? 14.2 -2147483648 -2147483648 -1.00 -1.00 112130 4 36 200 1.0 1.1 6 108 14.7 H 400 50 ON  
20110210_120724 ??? 14.2 -2147483648 -2147483648 -1.00 -1.00 112130 4 36 200 1.0 1.1 6 108 13.6 H 400 50 ON  
20110210_120758 ??? 14.3 -2147483648 -2147483648 -1.00 -1.00 112130 4 36 200 1.0 1.1 6 107 14.8 H 400 50 ON  
20110210_120832 ??? 14.3 -2147483648 -2147483648 -1.00 -1.00 112130 4 36 200 1.0 1.1 6 106 14.5 H 400 50 ON  


Abbassiamo un po' la lampada Lamp = 192

OFF: LJ47 + stages (z active) + ADC + FW + Rirot
TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph SR band exp #frames disturb notes
20110210_122027 ??? 15.0 -2147483648 -2147483648 -1.00 -1.00 112130 4 36 200 1.0 1.0 6 55 10.0 H 500 30 ON SR may be in error
20110210_122100 ??? 15.0 -2147483648 -2147483648 -1.00 -1.00 112130 4 36 200 1.0 1.0 6 55 10.7 H 500 30 ON SR may be in error
20110210_122133 ??? 14.9 -2147483648 -2147483648 -1.00 -1.00 112130 4 36 200 1.0 1.0 6 57 10.1 H 500 30 ON SR may be in error
20110210_122241 ??? 15.0 -2147483648 -2147483648 -1.00 -1.00 112130 4 36 200 1.0 1.0 6 54 8.6 H 500 30 ON  
20110210_122315 ??? 15.0 -2147483648 -2147483648 -1.00 -1.00 112130 4 36 200 1.0 1.0 6 55 8.9 H 500 30 ON  
20110210_122348 ??? 15.0 -2147483648 -2147483648 -1.00 -1.00 112130 4 36 200 1.0 1.0 6 55 8.7 H 500 30 ON  
Facciamo un load shape ripetiamo la stessa misura di prima nelle stesse condizioni

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph SR band exp #frames disturb notes
20110210_122620 ??? 15.0 -2147483648 -2147483648 -1.00 -1.00 112130 4 36 200 1.0 1.0 6 55 10.6 H 500 30 ON  
20110210_122653 ??? 15.0 -2147483648 -2147483648 -1.00 -1.00 112130 4 36 200 1.0 1.0 6 55 10.9 H 500 30 ON  
20110210_122726 ??? 14.9 -2147483648 -2147483648 -1.00 -1.00 112130 4 36 200 1.0 1.0 6 57 11.0 H 500 30 ON  
20110210_122835 ??? 15.0 -2147483648 -2147483648 -1.00 -1.00 112130 4 36 200 1.0 1.0 6 54 9.5 H 500 30 ON  
20110210_122908 ??? 15.0 -2147483648 -2147483648 -1.00 -1.00 112130 4 36 200 1.0 1.0 6 54 9.8 H 500 30 ON  
20110210_122942 ??? 14.9 -2147483648 -2147483648 -1.00 -1.00 112130 4 36 200 1.0 1.0 6 57 10.3 H 500 30 ON  

Abbassiamo la lampada Lamp=187 Pos=3
TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph SR band exp #frames disturb notes
20110210_125748 ??? 15.8 -2147483648 -2147483648 -1.00 -1.00 112130 4 36 200 0.7 0.9 6 25 4.0 H 500 30 ON  
20110210_125821 ??? 15.7 -2147483648 -2147483648 -1.00 -1.00 112130 4 36 200 0.7 0.9 6 28 4.4 H 500 30 ON  
20110210_125854 ??? 15.8 -2147483648 -2147483648 -1.00 -1.00 112130 4 36 200 0.7 0.9 6 26 3.9 H 500 30 ON  
20110210_130003 ??? 15.7 -2147483648 -2147483648 -1.00 -1.00 112130 4 36 200 0.7 0.9 6 27 4.8 H 500 30 ON SR may be in error
20110210_130036 ??? 15.7 -2147483648 -2147483648 -1.00 -1.00 112130 4 36 200 0.7 0.9 6 28 5.2 H 500 30 ON SR may be in error
20110210_130109 ??? 15.6 -2147483648 -2147483648 -1.00 -1.00 112130 4 36 200 0.7 0.9 6 30 5.3 H 500 30 ON SR may be in error

Facciamo un load shape e ripetiamo la misura
TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph SR band exp #frames disturb notes
20110210_130409 ??? 15.7 -2147483648 -2147483648 -1.00 -1.00 112130 4 36 200 0.7 0.9 6 27 6.3 H 500 30 ON SR may be in error
20110210_130442 ??? 15.8 -2147483648 -2147483648 -1.00 -1.00 112130 4 36 200 0.7 0.9 6 26 4.9 H 500 30 ON SR may be in error
20110210_130515 ??? 15.8 -2147483648 -2147483648 -1.00 -1.00 112130 4 36 200 0.7 0.9 6 26 4.8 H 500 30 ON  
20110210_130623 ??? 15.8 -2147483648 -2147483648 -1.00 -1.00 112130 4 36 200 0.7 0.9 6 25 4.7 H 500 30 ON SR may be in error
20110210_130656 ??? 15.7 -2147483648 -2147483648 -1.00 -1.00 112130 4 36 200 0.7 0.9 6 27 5.4 H 500 30 ON SR may be in error
20110210_130729 ??? 15.7 -2147483648 -2147483648 -1.00 -1.00 112130 4 36 200 0.7 0.9 6 28 5.8 H 500 30 ON SR may be in error
Ci mettiamo a 100Hz e abbassiamo la lampada

Lamp=181
Pos=3 (T=0.1%)

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph SR band exp #frames disturb notes
20110210_132906 ??? 16.3 -2147483648 -2147483648 -1.00 -1.00 112130 4 36 100 1.0 1.1 6 34 10.7 H 600 50 ON SR may be in error
20110210_132958 ??? 16.3 -2147483648 -2147483648 -1.00 -1.00 112130 4 36 100 1.0 1.1 6 32 4.9 H 600 50 ON SR may be in error
20110210_133051 ??? 16.3 -2147483648 -2147483648 -1.00 -1.00 112130 4 36 100 1.0 1.1 6 33 6.0 H 600 50 ON SR may be in error
20110210_133237 ??? 16.4 -2147483648 -2147483648 -1.00 -1.00 112130 4 36 100 1.0 1.1 6 29 2.2 H 600 50 ON  
20110210_133330 ??? 16.3 -2147483648 -2147483648 -1.00 -1.00 112130 4 36 100 1.0 1.1 6 32 6.3 H 600 50 ON  
20110210_133422 ??? 16.3 -2147483648 -2147483648 -1.00 -1.00 112130 4 36 100 1.0 1.1 6 33 8.7 H 600 50 ON  

Facciamo un loadshape e ripetiamo con stessi parametri
TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph SR band exp #frames disturb notes
20110210_133552 ??? 16.2 -2147483648 -2147483648 -1.00 -1.00 112130 4 36 100 1.0 1.1 6 35 3.3 H 600 50 ON  
20110210_133644 ??? 16.2 -2147483648 -2147483648 -1.00 -1.00 112130 4 36 100 1.0 1.1 6 35 3.3 H 600 50 ON  
20110210_133737 ??? 16.3 -2147483648 -2147483648 -1.00 -1.00 112130 4 36 100 1.0 1.1 6 33 2.6 H 600 50 ON  
20110210_133921 ??? 16.4 -2147483648 -2147483648 -1.00 -1.00 112130 4 36 100 1.0 1.1 6 29 2.4 H 600 50 ON  
20110210_134015 ??? 16.4 -2147483648 -2147483648 -1.00 -1.00 112130 4 36 100 1.0 1.1 6 30 2.0 H 600 50 ON  
20110210_134107 ??? 16.3 -2147483648 -2147483648 -1.00 -1.00 112130 4 36 100 1.0 1.1 6 31 2.1 H 600 50 ON  

AO RON TABLE, OFF: ADC + FW + Rirot + LJ47 + stages
Bin: 1 - Framerate  990 Hz (2500 kpix/sec) - RON (e-):   8.75 (estimated)
Bin: 2 - Framerate  990 Hz ( 800 kpix/sec) - RON (e-):   6.34 (estimated)
Bin: 2 - Framerate  625 Hz ( 380 kpix/sec) - RON (e-):   4.17 (estimated)
Bin: 2 - Framerate  400 Hz ( 380 kpix/sec) - RON (e-):   4.16 (estimated)
Bin: 3 - Framerate  200 Hz ( 380 kpix/sec) - RON (e-):   4.30 (estimated)
Bin: 4 - Framerate  300 Hz ( 335 kpix/sec) - RON (e-):   4.41 (estimated)
Bin: 4 - Framerate  200 Hz ( 335 kpix/sec) - RON (e-):   4.48 (estimated)
Bin: 4 - Framerate  105 Hz ( 335 kpix/sec) - RON (e-):   4.50 (estimated)



Bin 2

Nel rec usato fino ad ora a bin2 sono tagliati gli 8 modi che sono stati tolti per il FLAO1.

Li riabilitiamo

=======================================

REC 20110210 _151228
Modal Basis:
Modes =
intmatacq = 20110131_120310
n modes = 153
TT removal = ON
cutted = 0
Note: ...............

=======================================

Facciamo il bright side del bin 2 andando 1 kHz.

Sweep gain modal. (senza la sottrazione di 0.1)

Lamp = 255 Pos=4

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph SR band exp #frames disturb notes
20110210_153221 ??? 8.7 -2147483648 -2147483648 -1.00 -1.00 151228 2 153 991 0.5 0.6 3 837 57.7 H 100 200 ON  
20110210_153318 ??? 8.7 -2147483648 -2147483648 -1.00 -1.00 151228 2 153 991 0.5 0.6 3 838 55.8 H 100 200 ON  
20110210_153415 ??? 8.7 -2147483648 -2147483648 -1.00 -1.00 151228 2 153 991 0.5 0.6 3 838 57.5 H 100 200 ON  
20110210_153616 ??? 8.7 -2147483648 -2147483648 -1.00 -1.00 151228 2 153 991 0.5 0.6 3 850 63.9 H 100 200 ON SR may be in error
20110210_153716 ??? 8.7 -2147483648 -2147483648 -1.00 -1.00 151228 2 153 991 0.5 0.6 3 843 62.7 H 100 200 ON SR may be in error
20110210_153815 ??? 8.7 -2147483648 -2147483648 -1.00 -1.00 151228 2 153 991 0.5 0.6 3 839 61.5 H 100 200 ON SR may be in error
abbassiamo la lamp Lamp = 185

OFF = LJ47 + ADC + Rirot

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph SR band exp #frames disturb notes
20110210_154641 ??? 10.2 -2147483648 -2147483648 -1.00 -1.00 151228 2 153 991 0.4 0.5 3 216 58.3 H 200 100 ON  
20110210_154718 ??? 10.2 -2147483648 -2147483648 -1.00 -1.00 151228 2 153 991 0.4 0.5 3 216 57.8 H 200 100 ON  
20110210_154755 ??? 10.2 -2147483648 -2147483648 -1.00 -1.00 151228 2 153 991 0.4 0.5 3 216 58.0 H 200 100 ON  
20110210_154922 ??? 10.2 -2147483648 -2147483648 -1.00 -1.00 151228 2 153 991 0.4 0.5 3 206 63.8 H 200 100 ON SR may be in error
20110210_154959 ??? 10.1 -2147483648 -2147483648 -1.00 -1.00 151228 2 153 991 0.4 0.5 3 218 65.8 H 200 100 ON SR may be in error
20110210_155037 ??? 10.1 -2147483648 -2147483648 -1.00 -1.00 151228 2 153 991 0.4 0.5 3 219 72.2 H 200 100 ON SR may be in error

TEST NO MODULAZIONE

MOD=0 e sweep gain modal
TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph SR band exp #frames disturb notes
20110210_160004 ??? 8.8 -2147483648 -2147483648 -1.00 -1.00 151228 2 153 991 0.3 0.3 0 781 69.0 H 100 100 ON - Pyramid modulation mismatchSR may be in error
20110210_160031 ??? 8.8 -2147483648 -2147483648 -1.00 -1.00 151228 2 153 991 0.3 0.3 0 779 66.8 H 100 100 ON - Pyramid modulation mismatchSR may be in error
20110210_160059 ??? 8.8 -2147483648 -2147483648 -1.00 -1.00 151228 2 153 991 0.3 0.3 0 777 61.9 H 100 100 ON - Pyramid modulation mismatchSR may be in error
20110210_160205 ??? 8.8 -2147483648 -2147483648 -1.00 -1.00 151228 2 153 991 0.3 0.3 0 783 58.6 H 100 100 ON - Pyramid modulation mismatch
20110210_160233 ??? 8.8 -2147483648 -2147483648 -1.00 -1.00 151228 2 153 991 0.3 0.3 0 779 60.5 H 100 100 ON - Pyramid modulation mismatch
20110210_160301 ??? 8.8 -2147483648 -2147483648 -1.00 -1.00 151228 2 153 991 0.3 0.3 0 782 61.9 H 100 100 ON - Pyramid modulation mismatch

Rimettiamo 3l/D e riottimizziamo il gain
TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph SR band exp #frames disturb notes
20110210_160508 ??? 8.7 -2147483648 -2147483648 -1.00 -1.00 151228 2 153 991 0.4 0.5 3 841 59.2 H 100 100 ON  
20110210_160536 ??? 8.7 -2147483648 -2147483648 -1.00 -1.00 151228 2 153 991 0.4 0.5 3 840 -1.0 ? -1 -1 ON  
20110210_160557 ??? 8.7 -2147483648 -2147483648 -1.00 -1.00 151228 2 153 991 0.4 0.5 3 839 61.1 H 100 100 ON  
20110210_160703 ??? 8.7 -2147483648 -2147483648 -1.00 -1.00 151228 2 153 991 0.4 0.5 3 845 62.3 H 100 100 ON  
20110210_160731 ??? 8.7 -2147483648 -2147483648 -1.00 -1.00 151228 2 153 991 0.4 0.5 3 839 62.8 H 100 100 ON  
20110210_160758 ??? 8.7 -2147483648 -2147483648 -1.00 -1.00 151228 2 153 991 0.4 0.5 3 836 61.7 H 100 100 ON  

Ritogliamo la modulazione
TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph SR band exp #frames disturb notes
20110210_161111 ??? 8.8 -2147483648 -2147483648 -1.00 -1.00 151228 2 153 991 0.3 0.3 0 780 56.5 H 100 100 ON - Pyramid modulation mismatch
20110210_161139 ??? 8.8 -2147483648 -2147483648 -1.00 -1.00 151228 2 153 991 0.3 0.3 0 782 57.3 H 100 100 ON - Pyramid modulation mismatch
20110210_161206 ??? 8.8 -2147483648 -2147483648 -1.00 -1.00 151228 2 153 991 0.3 0.3 0 783 61.7 H 100 100 ON - Pyramid modulation mismatchSR may be in error
20110210_161312 ??? 8.8 -2147483648 -2147483648 -1.00 -1.00 151228 2 153 991 0.3 0.3 0 786 62.1 H 100 100 ON - Pyramid modulation mismatchSR may be in error
20110210_161340 ??? 8.8 -2147483648 -2147483648 -1.00 -1.00 151228 2 153 991 0.3 0.3 0 783 61.7 H 100 100 ON - Pyramid modulation mismatchSR may be in error
20110210_161408 ??? 8.8 -2147483648 -2147483648 -1.00 -1.00 151228 2 153 991 0.3 0.3 0 781 62.4 H 100 100 ON - Pyramid modulation mismatchSR may be in error



Torniamo ai test classici a bin 2

Fatto loadshape e ripetiamo il punto a 10.1
TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph SR band exp #frames disturb notes
20110210_162018 ??? 10.1 -2147483648 -2147483648 -1.00 -1.00 151228 2 153 991 0.5 0.5 3 221 60.0 H 200 100 ON  
20110210_162055 ??? 10.1 -2147483648 -2147483648 -1.00 -1.00 151228 2 153 991 0.5 0.5 3 221 57.7 H 200 100 ON  
20110210_162133 ??? 10.1 -2147483648 -2147483648 -1.00 -1.00 151228 2 153 991 0.5 0.5 3 219 58.2 H 200 100 ON  
20110210_162259 ??? 10.2 -2147483648 -2147483648 -1.00 -1.00 151228 2 153 991 0.5 0.5 3 201 57.3 H 200 100 ON  
20110210_162337 ??? 10.2 -2147483648 -2147483648 -1.00 -1.00 151228 2 153 991 0.5 0.5 3 213 55.6 H 200 100 ON  
20110210_162414 ??? 10.2 -2147483648 -2147483648 -1.00 -1.00 151228 2 153 991 0.5 0.5 3 217 55.0 H 200 100 ON  

Ripetiamo la misura come sopra
TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph SR band exp #frames disturb notes
20110210_165938 ??? 10.1 -2147483648 -2147483648 -1.00 -1.00 151228 2 153 991 0.5 0.5 3 219 -1.0 ? -1 -1 ON  
20110210_165959 ??? 10.2 -2147483648 -2147483648 -1.00 -1.00 151228 2 153 991 0.5 0.5 3 216 61.3 H 200 100 ON  
20110210_170036 ??? 10.2 -2147483648 -2147483648 -1.00 -1.00 151228 2 153 991 0.5 0.5 3 216 60.3 H 200 100 ON  
20110210_170202 ??? 10.2 -2147483648 -2147483648 -1.00 -1.00 151228 2 153 991 0.5 0.5 3 201 65.5 H 200 100 ON SR may be in error
20110210_170240 ??? 10.2 -2147483648 -2147483648 -1.00 -1.00 151228 2 153 991 0.5 0.5 3 214 71.1 H 200 100 ON SR may be in error
20110210_170317 ??? 10.1 -2147483648 -2147483648 -1.00 -1.00 151228 2 153 991 0.5 0.5 3 218 72.8 H 200 100 ON SR may be in error

Warning su SR_SE

I valori di SR a bin2 mag 10.2 variano fra 60 e 70%. Questa variazione e' molto grande suscita dei dubbi sulla sr_esposito.pro

Mettiamo un warning che avvisa quando il flusso sul subframe che si ingrandisce non converge al valore massimo.

"

-- EnricoPinna - 10 Feb 2011




bin1_novib=['20110209_120109','20110209_120157','20110209_120244','20110209_120936','20110209_121024','20110209_121110']

bin2_mag087=['20110210_153221','20110210_153318','20110210_153415','20110210_160508','20110210_160557','20110210_160703','20110210_160731',' 20110210_160758' ]

bin2_mag102=['20110210_162018','20110210_162055','20110210_162133','20110210_162259','20110210_162337','20110210_162414','20110210_165959',' 20110210_170036']

bin2_mag110=['20110211_105914','20110211_110009','20110211_110102' ]

bin3_novib=['20110209_160718',' 20110209_160747','20110209_160815','20110209_160925','20110209_160954',' 20110209_161022','20110209_163005','20110209_163034','20110209_163102','20110209_163211','20110209_163239','20110209_163308']

bin3_mag147=['20110209_164223','20110209_164251','20110209_164320','20110209_164423','20110209_164452','20110209_164520']

bin3_mag151=['20110209_173936','20110209_174004','20110209_174033 ','20110209_174138','20110209_174206','20110209_174234']

bin4_mag142=['20110210_120500','20110210_120534','20110210_120608','20110210_120724','20110210_120758','20110210_120832']

bin4_mag150=['20110210_122620','20110210_122653','20110210_122726','20110210_122835','20110210_122908','20110210_122942']

bin4_mag158=['20110210_130409','20110210_130442','20110210_130515','20110210_130623','20110210_130656','20110210_130729']

bin4_mag163=['20110210_132906','20110210_132958','20110210_133051','20110210_133237','20110210_133330','20110210_133422' ]

flao2_bin1 = obj_new('aodataset',[bin1_novib] )

flao2_bin2 = obj_new('aodataset',[bin2_mag087,bin2_mag102, bin2_mag110] )

flao2_bin3 = obj_new('aodataset',[bin3_novib, bin3_mag147, bin3_mag151] )

flao2_bin4 = obj_new('aodataset',[bin4_mag142,bin4_mag150,bin4_mag158,bin4_mag163] )

sr_b1 = flao2_bin1->value('irtc.sr_se')

sr_b2 = flao2_bin2->value('irtc.sr_se')

sr_b3 = flao2_bin3->value('irtc.sr_se')

sr_b4 = flao2_bin4->value('irtc.sr_se')

mag_b1 = flao2_bin1->value('mag')

mag_b2 = flao2_bin2->value('mag')

mag_b3 = flao2_bin3->value('mag')

mag_b4 = flao2_bin4->value('mag')

simul_table=fltarr(9,3)

simul_table[*,0]=[8.5,9.5,10.5,11.5,12.5,13.5,14.5,15.5,16.5]

simul_table[*,1]=[0.62,0.59,0.50,0.48,0.42,0.27,0.19,0.071,0.026]

simul_table[*,2]=[0.80,0.77,0.62,0.59,0.54,0.37,0.27,0.12,0.052]

plot, simul_table[*,0], simul_table[*,2], title='SR FLAO#2 @ tower testbench', xtitle='R+I mag',ytitle='SR value (H band)', charsize=2, yrange=[0,1]

oplot, simul_table[*,0], simul_table[*,2],col='00ff00'x

oplot, simul_table[*,0], simul_table[*,1],col='0000ff'x

oplot, mag_b1, sr_b1, psym=4

oplot, mag_b2, sr_b2, psym=6

oplot, mag_b3, sr_b3, psym=5

oplot, mag_b4, sr_b4, psym=2