Aux FW remotizzata

Vecchio PC di Alfio collegato via USB alla FW e poi via VNC si controlla con l'Hyperterm.

Tutto descritto su TowerConfigurations.

Rimozione readout speed lenti

I readout speed piu' lenti (150 kpix/sec ed equivalenti agli altri binning) sono stati rimossi dalla configurazione del ccd, in modo che non vengano piu' selezionati quando si imposta un frame rate.

test readout speed PRIMA:

Bin: 1 - Framerate 990 Hz - RON (ADU): 18.41 - RON (e-): 9.20 (estimated)
Bin: 2 - Framerate 990 Hz - RON (ADU): 13.32 - RON (e-): 6.66 (estimated)
Bin: 2 - Framerate 625 Hz - RON (ADU): 9.27 - RON (e-): 4.64 (estimated)
Bin: 2 - Framerate 400 Hz - RON (ADU): 9.01 - RON (e-): 4.51 (estimated)
Bin: 3 - Framerate 200 Hz - RON (ADU): 12.12 - RON (e-): 6.06 (estimated)
Bin: 4 - Framerate 300 Hz - RON (ADU): 13.02 - RON (e-): 6.51 (estimated)
Bin: 4 - Framerate 200 Hz - RON (ADU): 12.77 - RON (e-): 6.39 (estimated)
Bin: 4 - Framerate 105 Hz - RON (ADU): 12.95 - RON (e-): 6.47 (estimated)

test readout speed DOPO:

Bin: 1 - Framerate 990 Hz (2500 kpix/sec) - RON (ADU): 18.52 - RON (e-): 9.26 (estimated)
Bin: 2 - Framerate 990 Hz ( 800 kpix/sec) - RON (ADU): 21.78 - RON (e-): 10.89 (estimated)
Bin: 2 - Framerate 625 Hz ( 380 kpix/sec) - RON (ADU): 13.50 - RON (e-): 6.75 (estimated)
Bin: 2 - Framerate 400 Hz ( 380 kpix/sec) - RON (ADU): 13.52 - RON (e-): 6.76 (estimated)
Bin: 3 - Framerate 200 Hz ( 380 kpix/sec) - RON (ADU): 14.11 - RON (e-): 7.05 (estimated)
Bin: 4 - Framerate 300 Hz ( 335 kpix/sec) - RON (ADU): 14.86 - RON (e-): 7.43 (estimated)
Bin: 4 - Framerate 200 Hz ( 335 kpix/sec) - RON (ADU): 14.87 - RON (e-): 7.44 (estimated)
Bin: 4 - Framerate 105 Hz ( 335 kpix/sec) - RON (ADU): 14.96 - RON (e-): 7.48 (estimated)

Era meglio prima! Ma i problemi piu' grossi, ad esempio i 10 e- a bin2, non sembrano dipendere dall'eliminazione del 150 kpix...

Plottone con bin3 e bin4

bin1_600=['20110128_123831','20110128_123924','20110128_124012','20110128_125301','20110128_125349','20110128_125436']

bin1_400=['20110128_151231','20110128_151303','20110128_160317','20110128_160405','20110128_160439']

bin2_105=['20110131_122943','20110131_123006','20110131_123029','20110131_123616','20110131_123701','20110131_123726']

bin2_115=['20110131_142429','20110131_142455','20110131_143031','20110131_143505','20110131_143531','20110131_143554']

bin2_125=['20110131_144607','20110131_144634','20110131_144701','20110131_145140','20110131_145238','20110131_145308']

bin3_66=['20110207_155959','20110207_160052','20110207_160155']

bin4_36=['20110204_172936','20110204_173015','20110204_173050']

flao2 = obj_new('aodataset',[bin1_600,bin1_400,bin2_105, bin2_115, bin3_66, bin4_36] )

sr=flao2->value('irtc.sr_se')

mag=flao2->value('mag')

simul_table=fltarr(9,3)

simul_table[*,0]=[8.5,9.5,10.5,11.5,12.5,13.5,14.5,15.5,16.5]

simul_table[*,1]=[0.62,0.59,0.50,0.48,0.42,0.27,0.19,0.071,0.026]

simul_table[*,2]=[0.80,0.77,0.62,0.59,0.54,0.37,0.27,0.12,0.052]

plot, mag, sr, psym=4, title='SR FLAO#2 @ tower testbench', xtitle='R+I mag',ytitle='SR value (H band)', charsize=2

oplot, simul_table[*,0], simul_table[*,2],col='00ff00'x

oplot, simul_table[*,0], simul_table[*,1],col='0000ff'x


Mag 13.5 bin3

Il valore della lampada per ottenere un certo flusso non sembra molto riproducibile, prima di pranzo facevamo il flusso giusto con la pos=2, mentre ora dobbiamo farlo con la pos1 Lamp=117

Facciamo autofocus per Pos1



PROBLEMA DI PRODUZIONE FRAMES BCU CCD39

Ci accorgiamo che la diagnostica ha 2 frames per ogni frame che il CCD39 dovrebbe produrre.

Se si imposta 200Hz sul 39 il loop va a 400Hz.

Spento e riacceso LJ39.

Lo fa a Bin3 ma anche a bin2... a bin1 va bene.

Torniamo a bin2 e lo fa di nuovo.

Vediamo i frames salvati e sembrano frames veri e tutti diversi -> e' il ccd39 che e' impazzito?

Alfio ripristina la selezione dei ROSpeed come erano prima e torniamo alla normalita'


Riproviamo col punto a bin 3

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph SR band exp #frames disturb notes
20110207_155959 ??? 13.5 -2147483648 -2147483648 -1.00 -1.00 154626 3 66 400 0.4 0.7 3 55 19.1 H 600 30 ON - Pyramid modulation mismatch
20110207_160052 ??? 13.6 -2147483648 -2147483648 -1.00 -1.00 154626 3 66 400 0.4 0.7 3 52 19.5 H 600 30 ON - Pyramid modulation mismatch
20110207_160155 ??? 13.6 -2147483648 -2147483648 -1.00 -1.00 154626 3 66 400 0.4 0.7 3 53 18.8 H 600 30 ON - Pyramid modulation mismatch
Rifacciamo l'autogain dopo aver ripreso il dark

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph SR band exp #frames disturb notes
20110207_160329 ??? 13.6 -2147483648 -2147483648 -1.00 -1.00 154626 3 66 400 0.4 1.0 3 52 15.8 H 600 30 ON - Pyramid modulation mismatch
20110207_160418 ??? 13.6 -2147483648 -2147483648 -1.00 -1.00 154626 3 66 400 0.4 1.0 3 51 17.6 H 600 30 ON - Pyramid modulation mismatch
20110207_160447 ??? 13.6 -2147483648 -2147483648 -1.00 -1.00 154626 3 66 400 0.4 1.0 3 52 17.8 H 600 30 ON - Pyramid modulation mismatch
I risultati di bin 3 e 4 sono sotto la baseline.

Il pupil rirot fa alzare il ron a 400kpix/s da 4.6 a 4.9 e-

OFF: stages + pup rerot + LJ47
------------------------------ SUMMARY ------------------------------------
ccd39 - binning 1
Speed: 2500 kpix/sec - RON (ADU): 18.85 - RON (e-): 9.43 (estimated)
Speed: 890 kpix/sec - RON (ADU): 13.13 - RON (e-): 6.57 (estimated)
Speed: 400 kpix/sec - RON (ADU): 9.23 - RON (e-): 4.61 (estimated)
Speed: 150 kpix/sec - RON (ADU): 12.33 - RON (e-): 6.17 (estimated)

OFF: stages + pup rerot + LJ47 + ADC
------------------------------ SUMMARY ------------------------------------
ccd39 - binning 1
Speed: 2500 kpix/sec - RON (ADU): 18.60 - RON (e-): 9.30 (estimated)
Speed: 890 kpix/sec - RON (ADU): 13.01 - RON (e-): 6.51 (estimated)
Speed: 400 kpix/sec - RON (ADU): 8.64 - RON (e-): 4.32 (estimated)
Speed: 150 kpix/sec - RON (ADU): 10.59 - RON (e-): 5.29 (estimated)

OFF: stages + pup rerot + LJ47 + ADC + FWs
------------------------------ SUMMARY ------------------------------------
ccd39 - binning 1
Speed: 2500 kpix/sec - RON (ADU): 18.49 - RON (e-): 9.25 (estimated)
Speed: 890 kpix/sec - RON (ADU): 12.95 - RON (e-): 6.48 (estimated)
Speed: 400 kpix/sec - RON (ADU): 8.34 - RON (e-): 4.17 (estimated)
Speed: 150 kpix/sec - RON (ADU): 9.91 - RON (e-): 4.95 (estimated)

OFF: stages + pup rerot + LJ47 + ADC + FWs + Flowerpot
------------------------------ SUMMARY ------------------------------------
ccd39 - binning 1
Speed: 2500 kpix/sec - RON (ADU): 18.24 - RON (e-): 9.12 (estimated)
Speed: 890 kpix/sec - RON (ADU): 12.84 - RON (e-): 6.42 (estimated)
Speed: 400 kpix/sec - RON (ADU): 7.99 - RON (e-): 3.99 (estimated)
Speed: 150 kpix/sec - RON (ADU): 9.01 - RON (e-): 4.51 (estimated)

OFF: stages + + LJ47 + Flowerpot
------------------------------ SUMMARY ------------------------------------
ccd39 - binning 1
Speed: 2500 kpix/sec - RON (ADU): 18.57 - RON (e-): 9.29 (estimated)
Speed: 890 kpix/sec - RON (ADU): 13.14 - RON (e-): 6.57 (estimated)
Speed: 400 kpix/sec - RON (ADU): 9.96 - RON (e-): 4.98 (estimated)
Speed: 150 kpix/sec - RON (ADU): 12.83 - RON (e-): 6.41 (estimated)


TEST LOOP

Facciamo un loop chiuso di test ad alti fotoni per vedere se la causa delle basse performance รจ davvero il RON. Teniamo il resto uguale (bin3, etc).

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph SR band exp #frames disturb notes
20110207_172407 ??? 11.1 -2147483648 -2147483648 -1.00 -1.00 154626 3 66 502 0.7 0.8 0 432 20.5 H 200 50 ON - Pyramid modulation mismatch
20110207_172445 ??? 11.1 -2147483648 -2147483648 -1.00 -1.00 154626 3 66 502 0.7 0.8 0 433 23.2 H 200 50 ON - Pyramid modulation mismatch
20110207_172544 ??? 11.0 -2147483648 -2147483648 -1.00 -1.00 154626 3 66 502 0.7 0.8 0 438 25.4 H 200 50 ON - Pyramid modulation mismatch

Abbassiamo la lampada e riottimizziamo il gain, oscilla parecchio il TT

Si scopre che la MOD era zero!!! Ricominciamo

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph SR band exp #frames disturb notes
20110207_173949 ??? 11.1 -2147483648 -2147483648 -1.00 -1.00 154626 3 66 500 0.7 1.0 6 430 27.8 H 200 50 ON  
20110207_174016 ??? 11.1 -2147483648 -2147483648 -1.00 -1.00 154626 3 66 500 0.7 1.0 6 432 27.4 H 200 50 ON  
20110207_174044 ??? 11.1 -2147483648 -2147483648 -1.00 -1.00 154626 3 66 500 0.7 1.0 6 431 29.5 H 200 50 ON  

Si scopre che l'ADC stava girando lentamente !!!

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph SR band exp #frames disturb notes
20110207_174722 ??? 11.9 -2147483648 -2147483648 -1.00 -1.00 154626 3 66 500 0.5 1.1 6 201 22.2 H 200 50 ON  
20110207_174816 ??? 11.9 -2147483648 -2147483648 -1.00 -1.00 154626 3 66 500 0.5 1.1 6 200 22.6 H 200 50 ON  
20110207_174842 ??? 11.9 -2147483648 -2147483648 -1.00 -1.00 154626 3 66 500 0.5 1.1 6 200 25.6 H 200 50 ON  
Note: lampada settata a 190.

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph SR band exp #frames disturb notes
20110207_175458 ??? 12.6 -2147483648 -2147483648 -1.00 -1.00 154626 3 66 500 0.4 0.7 6 104 16.5 H 200 50 ON  
20110207_175534 ??? 12.6 -2147483648 -2147483648 -1.00 -1.00 154626 3 66 500 0.4 0.7 6 104 18.0 H 200 50 ON  
20110207_175641 ??? 12.6 -2147483648 -2147483648 -1.00 -1.00 154626 3 66 500 0.4 0.7 6 106 23.0 H 200 50 ON  
Note: lampada settata a 184.

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph SR band exp #frames disturb notes
20110207_180024 ??? 13.3 -2147483648 -2147483648 -1.00 -1.00 154626 3 66 500 0.3 0.5 6 53 14.5 H 600 50 ON  
20110207_180112 ??? 13.3 -2147483648 -2147483648 -1.00 -1.00 154626 3 66 500 0.3 0.5 6 53 13.7 H 600 50 ON  
20110207_180155 ??? 13.3 -2147483648 -2147483648 -1.00 -1.00 154626 3 66 500 0.3 0.5 6 54 13.6 H 600 50 ON  