  • La IRTC smontata per poter accedere alla fioriera
    SNC00371.jpg

  • La AUX filter wheel installata e cablata (mini USB + alimentazione)
    SNC00372.jpg

  • SNC00373.jpg:
    SNC00373.jpg



Test flusso con la AUX FW

Come da tabella nel log di ieri dovremmo avere

Pos 1 -> T=10%
Pos 2 -> T=1%
Pos 3 -> T=0.1%
Pos 4 -> T=100%
Pos 5 -> T=100%
Pos 6 -> T=100%

Controlliamo che i flussi siano quelli attesi

200Hz; Bin 1; Lamp=100%; TTAMP=6V
Pos 1 -> 118fot/subap ;drift= 2
Pos 2 -> 17fot/subap; drift=2
Pos 3 -> troppo pochi
Pos 4 -> 920 drift =3
Pos 5 -> 922 drift =2.5
Pos 6 -> 922 drift 1

200Hz; Bin 3; Lamp=100%; TTAMP=6V
Pos 6 -> 9400 drift 17
Pos 1 -> 1210 drift 3
Pos 2 -> 144 drift 1
Pos 3 -> 52 drift 0.2

200Hz; Bin 3; Lamp=100%; TTAMP=6V
Pos 2 -> 260 drift 3

200Hz; Bin 4; Lamp=100%; TTAMP=6l/D
Pos 2 -> 237 drift = -6



Focus IRTC con AuxFW=2

Prima ad alto flusso centriamo la PSF sul IRTC e poi facciamo il fuoco con la AuxFW in poszione e a 1 kHz

miglior fuoco z= 53.70


Punto mag 14.4 bin 4

Tabella di FLAO#1 da telescopio dice:
Mag= 14.40
fluxnorm= 841
bin= 4
CCD freq = 300
Fot/sub/frame = 45
Nmodes= 66

Facciamo autogain G = 0.7 0.57
TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph SR band exp #frames disturb notes
20110204_172936 ??? 14.7 -2147483648 -2147483648 -1.00 -1.00 112130 4 36 301 0.6 0.7 6 47 6.9 H 500 50 ON  

% READFITS: Now reading 320 by 256 array % AOPSF::BADPIXELMAP: BadPixelMap file not existing. Assume all pixel good
20110204_173015 ??? 14.7 -2147483648 -2147483648 -1.00 -1.00 112130 4 36 301 0.6 0.7 6 48 7.3 H 500 50 ON - oversampling freq not a multiple of loop freq

% READFITS: Now reading 320 by 256 array % AOPSF::BADPIXELMAP: BadPixelMap file not existing. Assume all pixel good
20110204_173050 ??? 14.7 -2147483648 -2147483648 -1.00 -1.00 112130 4 36 301 0.6 0.7 6 47 7.5 H 500 50 ON - oversampling freq not a multiple of loop freq
% AOMULTITON_ELAB::GETOBJ: Getting tracknum 20110204_172036

Bisogna ricontrolòlar eil calcolo dello SR perche' le PSF sembrano buone e non da 7%

  • psf.png:
    psf.png
I Attachment Action Size Date Who Comment
SNC00371.jpgjpg SNC00371.jpg manage 1 MB 04 Feb 2011 - 14:58 UnknownUser  
SNC00372.jpgjpg SNC00372.jpg manage 1 MB 04 Feb 2011 - 14:59 UnknownUser  
SNC00373.jpgjpg SNC00373.jpg manage 1 MB 04 Feb 2011 - 14:59 UnknownUser  
psf.pngpng psf.png manage 336 K 04 Feb 2011 - 16:41 UnknownUser  
Topic revision: r1 - 04 Feb 2011, EnricoPinna
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding Foswiki? Send feedback