You are here: Foswiki>FLAO Web>TowerLab>LabTest20110131 (09 Feb 2011, EnricoPinna)Edit Attach

TT-Focus OFFLOAD with Hexapode

Ven Luca ha installato il nuovo TCS, ora proviamo a far funzionare l'offload.

Va cambiata fisicamente la rete dell'esapodo, rimandiamo....

BIN2 ACQPUP

=======================================

Pup GREZZE= 20110131_113307
Centri =
Diam = 15.3pix
Dist = 18.00pix
TTMod = 6V 200Hz
Thr1 = 0.15
Thr2 = 0.30
=======================================

L'optical loop data va in ciampanelle quando cambi le pupille. Pare che usi quelle vecchie. Dobbiamo fermare il processo Optical Lood Data e poi quando riparte ha le pup corrette.

Pupille hottizzate: PUP 20110131_115300 165subap

INTMAT BIN2

Facciamo il 10 modi per centrare

=======================================

DISTURBOIM 20110131_115541
Modal basis = kl_20101207
type = Push-pull
Frames per mov = 3
Cycle = 60
#Modes = 10
Amp = 600_optimized_3l
Note =

=======================================

INTMATACQ 20110131_115637
Pup = 20110131_115300
Dist = 20110131_115541
Iteration = 4
Loop speed = 600
bin = 2
Modul = 3l/D
Rec.Close loop = none
Gain vector close loop = none

=======================================

REC 20110131_115801
Modal Basis: type
intmatacq = 20110131_115637
n modes = 10
TT removal = ON
cutted = 0
Note: Chiude

=======================================


Prendiamo la intmat a 153 modi

=======================================

DISTURBOIM 20110131_120133
Modal basis = kl_20101207
type = Push-pull
Frames per mov = 3
Cycle = 4
#Modes = 153
Amp = 600_optimized_3l
Note =

=======================================

INTMATACQ 20110131_120310
Pup = 20110131_115300
Dist = 20110131_120133
Iteration = 16
Loop speed = 600
bin = 2
Modul = 3l/D
Rec.Close loop = 20110131_115801
Gain vector close loop = 0.05
Note: ampiezze un po' basse nel plto, ma i valori sembrano buoni

=======================================

REC 20110131_120817
Modal Basis: type
intmatacq = 20110131_120310
n modes = 153
TT removal = ON
cutted = 0
Note: Chiude 600Hz G:0.5;0.4 no disturb

=======================================

REC 20110131_120133
Modal Basis: type
intmatacq = 20110131_120310
n modes = 120
TT removal = ON
cutted = 0
Note: Chiude 1000Hz G:0.45;0.35 no disturb

=======================================

Punto a mag 10.5

Gain ottimizzato a mano
TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph SR band exp #frames disturb notes
20110131_122943 ??? 10.8 -2147483648 -2147483648 -1.00 -1.00 120817 2 145 991 0.6 0.8 3 118 50.4 H 200 50 ON  
20110131_123006 ??? 10.8 -2147483648 -2147483648 -1.00 -1.00 120817 2 145 991 0.6 0.8 3 120 46.1 H 200 50 ON  
20110131_123029 ??? 10.8 -2147483648 -2147483648 -1.00 -1.00 120817 2 145 991 0.6 0.8 3 118 52.6 H 200 50 ON  

Gain ottimizzato con AUTOGAIN
TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph SR band exp #frames disturb notes
20110131_123616 ??? 10.8 -2147483648 -2147483648 -1.00 -1.00 120817 2 145 991 0.5 0.9 3 119 50.8 H 200 50 ON  
20110131_123701 ??? 10.8 -2147483648 -2147483648 -1.00 -1.00 120817 2 145 991 0.5 0.9 3 119 46.5 H 200 50 ON  
20110131_123726 ??? 10.8 -2147483648 -2147483648 -1.00 -1.00 120817 2 145 991 0.5 0.9 3 119 45.9 H 200 50 ON

Punto a 11.5

Abbassiamo la lampada e ottimizziamo il gain con autogain
TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph SR band exp #frames disturb notes
20110131_142429 ??? 11.2 -2147483648 -2147483648 -1.00 -1.00 120817 2 145 991 0.4 0.7 3 83 55.5 H 200 50 ON  
20110131_142455 ??? 11.4 -2147483648 -2147483648 -1.00 -1.00 120817 2 145 991 0.4 0.7 3 70 52.4 H 200 50 ON  
20110131_143031 ??? 11.3 -2147483648 -2147483648 -1.00 -1.00 120817 2 145 991 0.4 0.7 3 78 65.7 H 200 50 ON  
20110131_143505 ??? 11.5 -2147483648 -2147483648 -1.00 -1.00 120817 2 145 991 0.4 0.7 3 62 44.8 H 200 50 ON  
20110131_143531 ??? 11.6 -2147483648 -2147483648 -1.00 -1.00 120817 2 145 991 0.4 0.7 3 60 46.7 H 200 50 ON  
20110131_143554 ??? 11.6 -2147483648 -2147483648 -1.00 -1.00 120817 2 145 991 0.4 0.7 3 60 49.0 H 200 50 ON  

Punto a 12.5

20110131_144607 ??? 12.4 -2147483648 -2147483648 -1.00 -1.00 120817 2 145 625 0.4 1.0 3 44 36.1 H 300 50 ON  
20110131_144634 ??? 12.4 -2147483648 -2147483648 -1.00 -1.00 120817 2 145 625 0.4 1.0 3 43 38.1 H 300 50 ON - long stop of 27 frames at frame 3634
20110131_144701 ??? 12.4 -2147483648 -2147483648 -1.00 -1.00 120817 2 145 625 0.4 1.0 3 45 33.5 H 300 50 ON - long stop of 28 frames at frame 1349
20110131_145140 ??? 12.4 -2147483648 -2147483648 -1.00 -1.00 120817 2 145 625 0.4 1.0 3 43 32.7 H 300 50 ON - long stop of 46 frames at frame 1674
20110131_145238 ??? 12.4 -2147483648 -2147483648 -1.00 -1.00 120817 2 145 625 0.4 1.0 3 43 38.6 H 300 50 ON  
20110131_145308 ??? 12.4 -2147483648 -2147483648 -1.00 -1.00 120817 2 145 625 0.4 1.0 3 42 36.6 H 300 50 ON  

Mode offload

Acceso il nuovo TCS

OSS TSF IIF e AOS operativi

Ma il testo dell'offload e' negativo perche' la matrice POS2MODES e' ancora quella del LBT672a.

Questa matrice genera 15um di fuoco dove non sembra esserci un fuoco apprezzabile.

La IRTC funziona con il nuovo TCS

BIN3 PUPILLE

=======================================

Pup GREZZE = 20110131_172459
Centri = <coord1-coord2>
Diam = <#>pix
Dist = <#>pix
TTMod = <V+Hz or l/D>
Thr1 = <#>
Thr2 = <#>

=======================================

Pup hottizate 20110131_173154

=======================================

DISTURBOIM 20110131_174710
Modal basis = kl_20101207
type = Push-pull
Frames per mov = 3
Cycle = 60
#Modes = 10
Amp = 600_optimized_6l
Note =

=======================================

INTMATACQ 20110131_175435
save slopes command failed

-- EnricoPinna - 31 Jan 2011
  • acqpupil_bin2.png:
    acqpupil_bin2.png

  • IDL_0_31012011_14.54.14.jpg:
    IDL_0_31012011_14.54.14.jpg

  • IDL_0_31012011_15.03.17.jpg:
    IDL_0_31012011_15.03.17.jpg

  • IDL_0_31012011_16.49.39.jpg:
    IDL_0_31012011_16.49.39.jpg
Da esegeuire in elablib


bin1_600=['20110128_123831','20110128_123924','20110128_124012','20110128_125301','20110128_125349','20110128_125436']

bin1_400=['20110128_151231','20110128_151303','20110128_160317','20110128_160405','20110128_160439']

bin2_105=['20110131_122943','20110131_123006','20110131_123029','20110131_123616','20110131_123701','20110131_123726']

bin2_115=['20110131_142429','20110131_142455','20110131_143031','20110131_143505','20110131_143531','20110131_143554']

bin2_125=['20110131_144607','20110131_144634','20110131_144701','20110131_145140','20110131_145238','20110131_145308']

flao2 = obj_new('aodataset',[bin1_600,bin1_400,bin2_105, bin2_115] )

sr=flao2->value('irtc.sr_se')

mag=flao2->value('mag')

simul_table=fltarr(9,3)

simul_table[*,0]=[8.5,9.5,10.5,11.5,12.5,13.5,14.5,15.5,16.5]

simul_table[*,1]=[0.62,0.59,0.50,0.48,0.42,0.27,0.19,0.071,0.026]

simul_table[*,2]=[0.80,0.77,0.62,0.59,0.54,0.37,0.27,0.12,0.052]

plot, mag, sr, psym=4, title='SR FLAO#2 @ tower testbench', xtitle='R+I mag',ytitle='SR value (H band)', charsize=2

oplot, simul_table[*,0], simul_table[*,2],col='00ff00'x

oplot, simul_table[*,0], simul_table[*,1],col='0000ff'x


Topic revision: r8 - 09 Feb 2011, EnricoPinna
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding Foswiki? Send feedback