W#1 Linear power supply implemented RON TEST

CONDITIONS:

W#1 in the 304 lab
Linear power supply on the bench
BOX39 in the AGW frame
All disconnected but CCD39 to box39
Peltier ON

------------------------------ SUMMARY ------------------------------------
ccd39 - binning 1
Speed: 2500 kpix/sec - RON (ADU): 19.72 - RON (e-): 9.86 (estimated)
Speed: 890 kpix/sec - RON (ADU): 17.29 - RON (e-): 8.65 (estimated)
Speed: 400 kpix/sec - RON (ADU): 8.09 - RON (e-): 4.05 (estimated)
Speed: 150 kpix/sec - RON (ADU): 8.48 - RON (e-): 4.24 (estimated)
------------------------------ SUMMARY ------------------------------------
ccd39 - binning 1
Speed: 2500 kpix/sec - RON (ADU): 20.35 - RON (e-): 10.17 (estimated)
Speed: 890 kpix/sec - RON (ADU): 18.09 - RON (e-): 9.04 (estimated)
Speed: 400 kpix/sec - RON (ADU): 8.15 - RON (e-): 4.07 (estimated)
Speed: 150 kpix/sec - RON (ADU): 8.51 - RON (e-): 4.26 (estimated)
------------------------------ SUMMARY ------------------------------------
ccd39 - binning 1
Speed: 2500 kpix/sec - RON (ADU): 20.37 - RON (e-): 10.18 (estimated)
Speed: 890 kpix/sec - RON (ADU): 18.29 - RON (e-): 9.14 (estimated)
Speed: 400 kpix/sec - RON (ADU): 8.13 - RON (e-): 4.07 (estimated)
Speed: 150 kpix/sec - RON (ADU): 8.55 - RON (e-): 4.28 (estimated)

-- EnricoPinna - 23 Apr 2010