Open miniskirt sector to access #455

#455 deleted from list wo_pos and wo_curr

#455: the left contact is short circuit with actuator body

found #467 with right contact semi-desoldered (#467 = #648 mirror)

Found problem on external actuators: some gold contacts were broken.

Deep analisys over all external act: it was decided to remove one of the two contacts on the MIRR# 646 648 669 588

654 contact bended for avoiding grounding.

At shell ripped, 20 slews done.

Found one actuator pushing against the shell in horizon pointing. Manually displaced act MIRR #599 and #517.

NOTE: wood little piece inside 669.

-- RunaBriguglio - 03 Mar 2010
Topic revision: r2 - 04 Mar 2010, MarcoXompero
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.