-- RunaBriguglio - 03 Mar 2010

Chiedere a marco degli errori dsp all’avvio del load program

!!!! modificato l’rbitrator all parte SetFlatAo, commentando il check sull’elevazione

Altro drift test

Track: 20100302_184917

Partito : 2010-03-02 18:49:26

20° elevazione 2010-03-02 18:51:08.681597

Si torna indietro 2010-03-02 18:52:38.989113

Rip 2010-03-02 18:53:39.096593 a fine corsa, per colpa del #455

FASTDGN00 |WAR| 18677|2010-03-02 18:29:08.258642| FUNCTEMERGENCYST > CHDISTAVERAGE-0455 = 1.42004 [/home/aoacct/src/DiagnApp/Funct.h:25 ]

FASTDGN00 |INF| 18678|2010-03-02 18:29:08.258681| ADAM > Adam: disabling coils...

FASTDGN00 |DEB| 18679|2010-03-02 18:29:08.258722| ADAM > Command to Adam: #011300

FASTDGN00 |DEB| 18680|2010-03-02 18:29:08.259340| ADAM > Answer from Adam: >01^M#011300

FASTDGN00 |ERR| 18681|2010-03-02 18:29:08.259367| ADAM > Adam: coils disabling failed

To do: nel ciclo del pistonamento mettere un test_coils()

Escluso il #455 la shell setta correttamente

Ma nella MirGui non viene escluso

Altro drift test per elevazione

Track 20100302_192758

Inizio 2010-03-02 19:28:16.156294

Torna indietro 2010-03-02 19:29:04.175227

Muore alle 2010-03-02 19:30:05.186372 perché ha preso una botta

Altro test.r drift

Track 20100302_195256

Inizio: 2010-03-02 19:53:15.091638

20°elevaz |2010-03-02 19:54:12.395362

Si torna indietro

Rip alle |2010-03-02 19:55:41.92580

FASTDGN00 |WAR| 67403|2010-03-02 19:55:26.861126| FUNCTEMERGENCYST > CHDISTAVERAGE-0455 = 1.74355 [/home/aoacct/src/DiagnApp/Funct.h:258]

FASTDGN00 |INF| 67404|2010-03-02 19:55:26.861156| ADAM > Adam: disabling coils...

FASTDGN00 |DEB| 67405|2010-03-02 19:55:26.861185| ADAM > Command to Adam: #011300

FASTDGN00 |DEB| 67406|2010-03-02 19:55:26.861780| ADAM > Answer from Adam: >01^M#011300

FASTDGN00 |ERR| 67407|2010-03-02 19:55:26.861796| ADAM > Adam: coils disabling failed

FASTDGN00 |ERR| 67408|2010-03-02 19:55:26.861818| FUNCTEMERGENCYST > ADAM CAN'T DISABLE COILS [/home/aoacct/src/DiagnApp/Funct.h:263]

FASTDGN00 |WAR| 67409|2010-03-02 19:55:26.881444| FUNCTEMERGENCYST > CHDISTAVERAGE-0455 = 1.74355 [/home/aoacct/src/DiagnApp/Funct.h:258]

FASTDGN00 |INF| 67410|2010-03-02 19:55:26.881499| ADAM > Adam: disabling coils...

FASTDGN00 |DEB| 67411|2010-03-02 19:55:26.881520| ADAM > Command to Adam: #011300

FASTDGN00 |DEB| 67412|2010-03-02 19:55:26.882165| ADAM > Answer from Adam: >01^M#011300

FASTDGN00 |ERR| 67413|2010-03-02 19:55:26.882179| ADAM > Adam: coils disabling failed

:

nel test precedente non era stato disabilitato il 455 nella fast per un errore

infatti ancora quell’attuatore e’ saltato in posizione

FASTDGN00 |WAR| 67403|2010-03-02 19:55:26.861126| FUNCTEMERGENCYST > CHDISTAVERAGE-0455 = 1.74355 [/home/aoacct/src/DiagnApp/Funct.h:258]

FASTDGN00 |INF| 67404|2010-03-02 19:55:26.861156| ADAM > Adam: disabling coils...

FASTDGN00 |DEB| 67405|2010-03-02 19:55:26.861185| ADAM > Command to Adam: #011300

FASTDGN00 |DEB| 67406|2010-03-02 19:55:26.861780| ADAM > Answer from Adam: >01^M#011300

FASTDGN00 |ERR| 67407|2010-03-02 19:55:26.861796| ADAM > Adam: coils disabling failed

FASTDGN00 |ERR| 67408|2010-03-02 19:55:26.861818| FUNCTEMERGENCYST > ADAM CAN'T DISABLE COILS [/home/aoacct/src/DiagnApp/Funct.h:263]

FASTDGN00 |WAR| 67409|2010-03-02 19:55:26.881444| FUNCTEMERGENCYST > CHDISTAVERAGE-0455 = 1.74355 [/home/aoacct/src/DiagnApp/Funct.h:258]

FASTDGN00 |INF| 67410|2010-03-02 19:55:26.881499| ADAM > Adam: disabling coils...

FASTDGN00 |DEB| 67411|2010-03-02 19:55:26.881520| ADAM > Command to Adam: #011300

FASTDGN00 |DEB| 67412|2010-03-02 19:55:26.882165| ADAM > Answer from Adam: >01^M#011300

FASTDGN00 |ERR| 67413|2010-03-02 19:55:26.882179| ADAM > Adam: coils disabling failed

:

!!! modificata fsm_load_program per escludere il controllo sul #455:

print, setdiagnparam('FASTDGN00', 'ChDistAverage', 455, 455, ALARM_MIN=-1e6, WARNING_MIN=-1e6, WARNING_MAX=1e6, ALARM_MAX=1e6)

per verificare : print, setdiagnparam('FASTDGN00', 'ChDistAverage', 455, 455, ALARM_MIN=-1e6, WARNING_MIN=-1e6, WARNING_MAX=1e6, ALARM_MAX=1e6)

!!! cancellare la modifica

Controllare il comando di flat e la calibrazione del #591 (mirror=667)

Altro drift elevazione

Track 20100302_212813

inizio 2010-03-02 21:28:20.958

20°elevz 2010-03-02 21:29:22.493742

Indietro |2010-03-02 21:30:39.

Fine slew 2010-03-02 21:31:50.650601 bordo saltato per colpa del #451

2010-03-02 21:33: il #451 torna indietro

Ricominci lo slew |2010-03-02 21:34:06.1

20°elev |2010-03-02 21:34:52.

#218 tira corrente

|2010-03-02 21:35:20.9 si torna indietro

#451 tira corrente quando si è llo zentih, per colpa del driver di corrente del#455

Inizia lo slew 2010-03-02 21:37:53.1 ma annullato per troppe oscillazioni

#455 without curr

Ulteriore run di elevazione, più volte continue

Track 20100302_220239

Inizio |2010-03-02 22:02:55.496566

Fine 2010-03-02 22:09:44.880223

FASTDGN00 |WAR| 15730|2010-03-02 22:09:44.902870| FUNCTWARNING > FunctWarning CHDISTRMS-0485 3.30863e-08

FASTDGN00 |ERR| 15731|2010-03-02 22:09:44.964116| FUNCTALARM > FunctAlarm CHDISTRMS-0485 5.04917e-07

FASTDGN00 |WAR| 15732|2010-03-02 22:09:44.979020| FUNCTWARNING > FunctWarning CHINTCONTROLCURRENT-0485 0.308269

FASTDGN00 |ERR| 15733|2010-03-02 22:09:44.981502| FUNCTALARM > FunctAlarm CHDISTRMS-0485 4.87414e-07

FASTDGN00 |WAR| CHINTCONTROLCURRENT 15734|2010-03-02 22:09:44.999431| FUNCTWARNING > FunctWarning CHINTCONTROLCURRENT-0485 0.322117

Altro run

Track 20100302_221736

Inizio 2010-03-02 22:17:54.86

Torna indietro 2010-03-02 22:19:49.881 problemi correnti #451

Su di nuovo 2010-03-02 22:21:00.0

Indietro 2010-03-02 22:21:36. problemi #451

FASTDGN00 |WAR| 73094|2010-03-02 22:22:07.161212| FUNCTWARNING > FunctWarning CHINTCONTROLCURRENT-0451 -0.511577

FASTDGN00 |WAR| 73095|2010-03-02 22:22:07.173037| FUNCTWARNING > FunctWarning CHINTCONTROLCURRENT-0451 -0.51148

Su di nuovo 2010-03-02 22:23:42.870

Indietro 2010-03-02 22:24:20.87

Problemi #451 2010-03-02 22:24:49.298400 poi ritorna

Di nuovo su 2010-03-02 22:26:16.8

Rip 2010-03-02 22:29:11.84

FASTDGN00 |WAR| 86357|2010-03-02 22:28:53.401780| FUNCTEMERGENCYST > CHCURRAVERAGE-0000 = -0.8 [/home/aoacct/src/DiagnApp/Funct.h:258]

FASTDGN00 |INF| 86358|2010-03-02 22:28:53.401803| ADAM > Adam: disabling coils...

FASTDGN00 |DEB| 86359|2010-03-02 22:28:53.401822| ADAM > Command to Adam: #011300

FASTDGN00 |DEB| 86360|2010-03-02 22:28:53.402472| ADAM > Answer from Adam: >01^M#011300

FASTDGN00 |ERR| 86361|2010-03-02 22:28:53.402485| ADAM > Adam: coils disabling failed

FASTDGN00 |ERR| 86362|2010-03-02 22:28:53.402556| FUNCTEMERGENCYST > ADAM CAN'T DISABLE COILS [/home/aoacct/src/DiagnAp

Altro run

Track 20100302_230741

Inizio 2010-03-02 23:07:52.65151

FASTDGN00 |WAR| 159900|2010-03-02 23:09:45.192933| FUNCTEMERGENCYST > CHCURRAVERAGE-0000 = -0.8 [/home/aoacct/src/DiagnApp/Funct.h:258]

FASTDGN00 |INF| 159901|2010-03-02 23:09:45.192957| ADAM > Adam: disabling coils...

FASTDGN00 |DEB| 159902|2010-03-02 23:09:45.192983| ADAM > Command to Adam: #011300

FASTDGN00 |DEB| 159903|2010-03-02 23:09:45.193627| ADAM > Answer from Adam: >01^M#011300

FASTDGN00 |ERR| 159904|2010-03-02 23:09:45.193645| ADAM > Adam: coils disabling failed

FASTDGN00 |ERR| 159905|2010-03-02 23:09:45.193671| FUNCTEMERGENCYST > ADAM CAN'T DISABLE COILS [/home/aoacct/src/DiagnApp/Funct.h:263]

FASTDGN00 |WAR| 159906|2010-03-02 23:09:45.198075| FUNCTWARNING > FunctWarning CHINTCONTROLCURRENT-0000 -0.62356

FASTDGN00 |ERR| 159907|2010-03-02 23:09:45.199415| FUNCTALARM > FunctAlarm CHINTCONTROLCURRENT-0342 -0.698602

FASTDGN00 |WAR| 159908|2010-03-02 23:09:45.215055| FUNCTEMERGENCYST > CHCURRAVERAGE-0000 = -0.8 [/home/aoacct/src

Settata la shell

Molta corrente su#455

FASTDGN00 |WAR| 203457|2010-03-02 23:15:01.934963| FUNCTWARNING > FunctWarning CHINTCONTROLCURRENT-0451 0.474482

FASTDGN00 |WAR| 203458|2010-03-02 23:15:01.954982| FUNCTWARNING > FunctWarning CHINTCONTROLCURRENT-0451 0.474426

FASTDGN00 |WAR| 203459|2010-03-02 23:15:01.975334| FUNCTWARNING > FunctWarning CHINTCONTROLCURRENT-0451 0.4746

FASTDGN00 |WAR| 203460|2010-03-02 23:15:01.995146| FUNCTWARNING > FunctWarning CHINTCONTROLCURRENT-0451 0.474599

Altro run

Track 20100302_232004

Inizio 2010-03-02 23:20:16.373

Verificare #451 all’orizzonte

Quando è allo zenith di nuovo:

FASTDGN00 |WAR| 246311|2010-03-02 23:35:20.980237| FUNCTWARNING > FunctWarning CHINTCONTROLCURRENT-0451 -0.503581

FASTDGN00 |WAR| 246312|2010-03-02 23:35:21.000161| FUNCTWARNING > FunctWarning CHINTCONTROLCURRENT-0451 -0.503822

Test a tenere a bassa elevazione il secondario per un po’, per fargli tirare piu’ corrente piu’ alungo ed evidenziare una dipendenza dei salti dalla temperature

Test started: 23:43:07.85019

Test ends at 2010-03-02 23:51:50.34281

L’effetto non scompare

Su di nuovo: 2010-03-02 23:55:11.487413

A 20° elev scompare

Giù

Verifica: sollevando la sgroud dietro il crate 4 (#455) il chccontrolcurrent scompare
Topic revision: r1 - 03 Mar 2010, RunaBriguglio
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding Foswiki? Send feedback