New functional test document

Following the functional checks done in the previous days, a new version (revision "C") of the W unit functional check document is uploaded in the "FLAO Handhover" wiki page http://aowiki.arcetri.astro.it/FLAO/FlaoHandoverDocuments

The new revision contains minor updates regarding the SX unit, and some small fixes in the test sequence.

IRTC dichroic measurement

We measure the dichroic angle with the IRTC on the clean room floor. After 3 measurements of the IRTC flange and of the dichroic, the angle is determined to be 14.9681 +/-0.004, which is inside the error bars of the reference value ( 14.966 +/- 0.004). Therefore there is no need of shimming the dichroic.

IRTC mating to AGW

We lift the IRTC with the clean room crane and mate it to the AGW. In order to do this, several small parts of the AGW cart must be disassembled since they are in the way of the IRTC flange.

-- AlfioPuglisi - 05 Feb 2016