Test Tree House FAN

TH OFF

Jeff dice che hanno modificato il fan della tree house e cosi' facciamo un test a loop chiuso con la TH spenta e poi accesa SN off
TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR band exp #frames disturb notes
20110605_160507 ??? 8.4 90 6 -1.00 -1.00 092604 1 400 990 0.2 0.4 3 269 ON 84.0 FeII 1.64 um 5000 2 OFF - Pupils mismatch - Background correction failed
20110605_160646 ??? 8.2 90 4 -1.00 -1.00 092604 1 400 990 0.2 0.4 3 312 ON 0.0 FeII 1.64 um 5000 2 OFF - Pupils mismatch - Center of PSF estimation failed
20110605_160919 ??? 8.3 90 1 -1.00 -1.00 092604 1 400 990 0.2 0.5 3 272 ON 81.2 FeII 1.64 um 5000 2 OFF - Pupils mismatch

SN on
TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR band exp #frames disturb notes
20110605_161356 ??? 8.4 90 3 -1.00 -1.00 092604 1 400 990 0.2 0.5 3 269 ON 79.7 FeII 1.64 um 5000 2 OFF - Pupils mismatch - Background correction failed
20110605_161505 ??? 8.3 90 4 -1.00 -1.00 092604 1 400 990 0.2 0.5 3 276 ON 77.6 FeII 1.64 um 5000 2 OFF - Pupils mismatch

TH ON

SN off
TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR band exp #frames disturb notes
20110605_162636 ??? 8.4 90 3 -1.00 -1.00 092604 1 400 990 0.2 0.5 3 269 ON 73.5 FeII 1.64 um 5000 2 OFF - Pupils mismatch
20110605_162802 ??? 8.3 90 3 -1.00 -1.00 092604 1 400 990 0.2 0.5 3 274 ON 74.5 FeII 1.64 um 5000 2 OFF - Pupils mismatch

SN on
TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR band exp #frames disturb notes
20110605_171039 ??? 8.4 90 4 -1.00 -1.00 092604 1 400 990 0.2 0.5 3 251 ON 83.3 FeII 1.64 um 5000 2 OFF - Pupils mismatch - Background correction failed

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR band exp #frames disturb notes
20110605_163001 ??? 8.3 90 6 -1.00 -1.00 092604 1 400 990 0.2 0.5 3 274 ON 75.4 FeII 1.64 um 5000 2 OFF - Pupils mismatch
20110605_163110 ??? 8.3 90 2 -1.00 -1.00 092604 1 400 990 0.2 0.5 3 276 ON 75.8 FeII 1.64 um 5000 2 OFF - Pupils mismatch

NCP Aberr correction

Rifacciamo il FEII per vedere se vengono comparabili

SN 20110605_165052 del NCP correction Quest eSN sembranno essere diverse da quelle di ieri che infatti
Mode 2 = -1.12E-8
Mode3 = 9.64E-10
Mode4 = -1.42E-8
Mode5 = 1.86E-9

SN ON
TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR band exp #frames disturb notes
20110605_165125 ??? 8.4 90 0 -1.00 -1.00 092604 1 400 990 0.2 0.5 3 270 ON 84.8 FeII 1.64 um 2000 2 OFF - Pupils mismatch
20110605_165227 ??? 8.3 90 2 -1.00 -1.00 092604 1 400 990 0.2 0.5 3 272 ON 81.0 FeII 1.64 um 5000 2 OFF - Pupils mismatch
20110605_165339 ??? 8.3 90 1 -1.00 -1.00 092604 1 400 990 0.2 0.5 3 275 ON 81.4 FeII 1.64 um 5000 2 OFF - Pupils mismatch - Background correction failed

SN OFF
TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR band exp #frames disturb notes
20110605_165458 ??? 8.3 90 4 -1.00 -1.00 092604 1 400 990 0.2 0.5 3 276 ON 76.5 FeII 1.64 um 5000 2 OFF - Pupils mismatch
20110605_165617 ??? 8.3 90 3 -1.00 -1.00 092604 1 400 990 0.2 0.5 3 277 ON 75.9 FeII 1.64 um 5000 2 OFF - Pupils mismatch
I file di SN da ieri a oggi sono cambiati in modo totale ed entrambi funzionano. Verifichiamo che ROT del telescopio era in 2 posizioni diverse. Ieri era a 211 Oggi 188

Anche la posizione nel campo e' diversa (slitt ein pos differente)

Rimettiamo il ROT a 211

SN di ieri con la rotazione che c'e' adesso
TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR band exp #frames disturb notes
20110605_171039 ??? 8.4 90 4 -1.00 -1.00 092604 1 400 990 0.2 0.5 3 251 ON 83.3 FeII 1.64 um 5000 2 OFF - Pupils mismatch - Background correction failed
20110605_171154 ??? 8.4 90 4 -1.00 -1.00 092604 1 400 990 0.2 0.5 3 256 ON 81.4 FeII 1.64 um 5000 2 OFF - Pupils mismatch

SN oggi prese con la rotazione diversa
20110605_171305 ??? 8.4 90 6 -1.00 -1.00 092604 1 400 990 0.2 0.5 3 258 ON 72.4 FeII 1.64 um 5000 2 OFF - Pupils mismatch - Background correction failed
20110605_171428 ??? 8.4 90 7 -1.00 -1.00 092604 1 400 990 0.2 0.5 3 256 ON 70.8 FeII 1.64 um 5000 2 OFF - Pupils mismatch - Background correction failed

Ora spostiamo le slitte e ci rimettiamo nella pos di ieri (non al centro del frame) SN ieri
TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR band exp #frames disturb notes
20110605_171917 ??? 8.4 90 4 -1.00 -1.00 092604 1 400 990 0.2 0.5 3 250 ON 81.6 FeII 1.64 um 5000 2 OFF - Pupils mismatch
20110605_172026 ??? 8.4 90 6 -1.00 -1.00 092604 1 400 990 0.2 0.5 3 257 ON 78.9 FeII 1.64 um 5000 2 OFF - Pupils mismatch

SN oggi
TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR band exp #frames disturb notes
20110605_172244 ??? 8.4 90 3 -1.00 -1.00 092604 1 400 990 0.2 0.5 3 254 ON 71.6 FeII 1.64 um 5000 2 OFF - Pupils mismatch - Background correction failed
20110605_172357 ??? 8.4 90 3 -1.00 -1.00 092604 1 400 990 0.2 0.5 3 261 ON 72.4 FeII 1.64 um 5000 2 OFF - Pupils mismatch - Background correction failed

Ora ruotiamo il ROT nella posizione di oggi e riproviamo in questa posizione del campo

SN ieri
TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR band exp #frames disturb notes
20110605_173853 ??? 8.5 90 4 -1.00 -1.00 092604 1 400 990 0.2 0.4 3 240 ON 73.5 FeII 1.64 um 5000 2 OFF - Pupils mismatch
20110605_174003 ??? 8.5 90 1 -1.00 -1.00 092604 1 400 990 0.2 0.4 3 244 ON 72.7 FeII 1.64 um 5000 2 OFF - Pupils mismatch

SN oggi
TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR band exp #frames disturb notes
20110605_174126 ??? 8.5 90 6 -1.00 -1.00 092604 1 400 990 0.2 0.4 3 246 ON 78.9 FeII 1.64 um 5000 2 OFF - Pupils mismatch - Background correction failed
20110605_174234 ??? 8.4 90 5 -1.00 -1.00 092604 1 400 990 0.2 0.4 3 248 ON 79.1 FeII 1.64 um 5000 2 OFF - Pupils mismatch - Background correction failed

NCP Kshort

Misura SN: 20110605_181441

Best modal coefficients:
Mode 2 coefficient -2.69e-08
Mode 3 coefficient -5.84e-09
Mode 4 coefficient -1.59e-08
Mode 11 coefficient -4.9e-10

Ripetiamo la misura delle SN per vedere che siano ripetibili: 20110605_182314

Best modal coefficients:
Mode 2 coefficient -9.81e-09
Mode 3 coefficient -1.94e-09
Mode 4 coefficient -1.62e-08
Mode 11 coefficient 1.15e-08

Di nuovo: 20110605_183253

Best modal coefficients:
Mode 2 coefficient -3.28e-08
Mode 3 coefficient -3.12e-10
Mode 4 coefficient -1.67e-08
Mode 11 coefficient 9.61e-09

Proviamo le vaie SN trovate in cloop

SN off
TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20110605_183550 ??? 8.5 90 7 -1.00 -1.00 092604 1 400 990 0.2 0.4 3 244 ON 70.0 Ks 1500 7 OFF NO - Pupils mismatch
20110605_183829 ??? 8.4 90 4 -1.00 -1.00 092604 1 400 990 0.2 0.4 3 248 ON 70.9 Ks 1500 7 OFF NO - Pupils mismatch - Background correction failed

SN le seconde misurate
TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20110605_184050 ??? 8.4 90 9 -1.00 -1.00 092604 1 400 990 0.2 0.4 3 250 ON 73.9 Ks 1500 7 OFF 182314 - Pupils mismatch
20110605_184318 ??? 8.4 90 7 -1.00 -1.00 092604 1 400 990 0.2 0.4 3 253 ON 73.9 Ks 1500 7 OFF 182314 - Pupils mismatch

SN le terze misurate
20110605_184542 ??? 8.4 90 8 -1.00 -1.00 092604 1 400 990 0.2 0.4 3 253 ON 70.9 Ks 1500 7 OFF 183253 - Pupils mismatch
20110605_184754 ??? 8.4 90 7 -1.00 -1.00 092604 1 400 990 0.2 0.4 3 256 ON 72.5 Ks 1500 7 OFF 183253 - Pupils mismatch

SN le prime misurate
20110605_184754 ??? 8.4 90 7 -1.00 -1.00 092604 1 400 990 0.2 0.4 3 256 ON 72.5 Ks 1500 7 OFF 183253 - Pupils mismatch
20110605_185133 ??? 8.4 90 3 -1.00 -1.00 092604 1 400 990 0.2 0.4 3 251 ON 72.0 Ks 1500 7 OFF 181441 - Pupils mismatch

TH OFF

Riprendiamo lo SR con le SN OFF
TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20110605_190537 ??? 8.5 90 7 -1.00 -1.00 092604 1 400 990 0.2 0.4 3 246 ON 76.1 Ks 1500 7 OFF NO - Pupils mismatch
20110605_190843 ??? 8.4 90 6 -1.00 -1.00 092604 1 400 990 0.2 0.4 3 252 ON 76.5 Ks 1500 7 OFF NO - Pupils mismatch

SN le seconde misurate
TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20110605_191109 ??? 8.4 90 5 -1.00 -1.00 092604 1 400 990 0.2 0.4 3 258 ON 78.1 Ks 1500 7 OFF 182314 - Pupils mismatch
20110605_191451 ??? 8.4 90 7 -1.00 -1.00 092604 1 400 990 0.2 0.4 3 253 ON 78.3 Ks 1500 7 OFF 182314 - Pupils mismatch
Rimisurioamo le SN 20110605_192811 Molto simili a quelle misurate con TH on Check SR

SN OFF
TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20110605_192936 ??? 8.5 90 8 -1.00 -1.00 092604 1 400 990 0.2 0.4 3 245 ON 75.0 Ks 1500 7 OFF NO - Pupils mismatch - Background correction failed
20110605_193151 ??? 8.4 90 9 -1.00 -1.00 092604 1 400 990 0.2 0.4 3 253 ON 75.4 Ks 1500 7 OFF NO - Pupils mismatch

SN 192811
TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20110605_193407 ??? 8.4 90 8 -1.00 -1.00 092604 1 400 990 0.2 0.4 3 254 ON 77.7 Ks 1500 7 OFF 192811 - Pupils mismatch
20110605_193626 ??? 8.4 90 5 -1.00 -1.00 092604 1 400 990 0.2 0.4 3 254 ON 77.6 Ks 1500 7 OFF 192811 - Pupils mismatch - Background correction failed

Passiamo ad H2 - 2.12 um

Best modal coefficients:
Mode 2 coefficient -6.21e-09
Mode 3 coefficient -9.55e-09
Mode 4 coefficient -2.16e-08
Mode 11 coefficient 8.18e-09
Saving total offset: /home/aoacct/AO/current/calib/wfs/current/slopenulls/bin1/20110605_200335.fits

SN OFF
TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20110605_200504 ??? 8.5 90 10 -1.00 -1.00 092604 1 400 990 0.2 0.4 3 243 ON 76.1 H2 2.122 um 10000 1 OFF NO - Pupils mismatch - Background correction failed
20110605_200604 ??? 8.4 90 10 -1.00 -1.00 092604 1 400 990 0.2 0.4 3 247 ON 77.8 H2 2.122 um 10000 1 OFF NO - Pupils mismatch

SN ON
TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20110605_200706 ??? 8.4 90 12 -1.00 -1.00 092604 1 400 990 0.2 0.4 3 251 ON 81.6 H2 2.122 um 10000 1 OFF 200335 - Pupils mismatch - SR may be in error
20110605_200801 ??? 8.4 90 7 -1.00 -1.00 092604 1 400 990 0.2 0.4 3 253 ON 80.7 H2 2.122 um 10000 1 OFF 200335 - Pupils mismatch - Background correction failed

Long exposure SN ON
TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20110605_201834 ??? 8.5 90 8 -1.00 -1.00 092604 1 400 990 0.2 0.4 3 245 ON 83.7 H2 2.122 um 20000 1 OFF 200335 - Pupils mismatch
Atmosfera ON, slopenull OFF

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20110605_202611 ??? 8.4 90 11 -1.00 -1.00 092604 1 400 990 0.4 0.4 3 252 ON 76.9 H2 2.122 um 20000 1 ON NO - Pupils mismatch - Background correction failed
20110605_202859 ??? 8.4 90 3 -1.00 -1.00 092604 1 400 990 0.4 0.4 3 254 ON 77.1 H2 2.122 um 20000 1 ON NO - Pupils mismatch

Atmosfera ON, slopenull ON
TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20110605_203041 ??? 8.4 90 8 -1.00 -1.00 092604 1 400 990 0.4 0.4 3 258 ON 81.1 H2 2.122 um 20000 1 ON 200335 - Pupils mismatch - Background correction failed
20110605_203155 ??? 8.4 90 9 -1.00 -1.00 092604 1 400 990 0.4 0.4 3 260 ON 81.0 H2 2.122 um 20000 1 ON 200335 - Pupils mismatch - Background correction failed

Ks Disturb ON SN off
TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20110605_211604 ??? 8.4 90 9 -1.00 -1.00 092604 1 400 990 0.4 0.5 3 251 ON 76.0 Ks 1500 7 ON NO - Pupils mismatch
20110605_211815 ??? 8.4 90 9 -1.00 -1.00 092604 1 400 990 0.4 0.5 3 258 ON 78.3 Ks 1500 7 ON NO - Pupils mismatch

Ks Disturb ON SN di H2
TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20110605_212044 ??? 8.4 90 7 -1.00 -1.00 092604 1 400 990 0.4 0.5 3 261 ON 78.6 Ks 1500 7 ON 200335 - Pupils mismatch - Background correction failed
20110605_212302 ??? 8.4 90 10 -1.00 -1.00 092604 1 400 990 0.4 0.5 3 264 ON 80.9 Ks 1500 7 ON 200335 - Pupils mismatch

Ks Disturb ON SN di Ks
TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20110605_213936 ??? 8.4 90 10 -1.00 -1.00 092604 1 400 990 0.4 0.5 3 252 ON 82.6 Ks 1500 7 ON 192811 - Pupils mismatch
20110605_214304 ??? 8.4 90 7 -1.00 -1.00 092604 1 400 990 0.4 0.5 3 256 ON 81.8 Ks 1500 7 ON 192811 - Pupils mismatch

Passiamo a NCP @ BIN2

Facciamo le NCP ab misurandole con il distrubo per tenere conto della correzione parziale Mag11

Bin2 Fe II

Best modal coefficients:
Mode 2 coefficient 1.95e-09
Mode 3 coefficient -1.82e-09
Mode 4 coefficient -7.75e-09
Mode 11 coefficient 1.52e-09

Saving total offset: /home/aoacct/AO/current/calib/wfs/current/slopenulls/bin2/20110605_222701.fits

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20110605_223432 ??? 11.2 90 12 -1.00 -1.00 180534 2 145 991 0.3 0.7 3 84 ON 54.6 FeII 1.64 um 10000 2 ON NO - Background correction failed
20110605_223614 ??? 11.1 90 15 -1.00 -1.00 180534 2 145 991 0.3 0.7 3 88 ON 54.2 FeII 1.64 um 10000 2 ON NO  
20110605_223747 ??? 11.1 90 8 -1.00 -1.00 180534 2 145 991 0.3 0.7 3 92 ON 56.7 FeII 1.64 um 10000 2 ON 222701  
20110605_223917 ??? 11.1 90 8 -1.00 -1.00 180534 2 145 991 0.3 0.7 3 93 ON 55.9 FeII 1.64 um 10000 2 ON 222701 - Background correction failed

Bin2 H2 2.12 um

Best modal coefficients:
Mode 2 coefficient 2.69e-09
Mode 3 coefficient -4.35e-09
Mode 4 coefficient -9.23e-09
Mode 11 coefficient 2.64e-09
Saving total offset: /home/aoacct/AO/current/calib/wfs/current/slopenulls/bin2/20110605_225830.fits

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20110605_230017 ??? 11.2 90 5 -1.00 -1.00 180534 2 145 991 0.3 0.7 3 87 ON 70.6 H2 2.122 um 10000 2 ON NO - SR may be in error
20110605_230210 ??? 11.1 90 9 -1.00 -1.00 180534 2 145 991 0.3 0.7 3 90 ON 68.6 H2 2.122 um 10000 2 ON NO - SR may be in error
20110605_230341 ??? 11.1 90 6 -1.00 -1.00 180534 2 145 991 0.3 0.7 3 91 ON 71.9 H2 2.122 um 10000 2 ON 225830  
20110605_230509 ??? 11.0 90 7 -1.00 -1.00 180534 2 145 991 0.3 0.7 3 98 ON 72.6 H2 2.122 um 10000 2 ON 225830  