AO816 R=7.2

011000 Pronti
011100 Errore AOS, si torna alla versione precedente
011540 Da' ancora problemi. La LUT del TipTilt e' sbagliata, modulazione troppo alta
011750 Corretto
012100 Dimm 0.8 a el=56
012100 Acquired
012140 Rimanda il preset
012410 Loop chiuso - Safe Skip
012450 Si rifa manuale
013000 Chiusi
013130 Mirror ventilation is on
013750 Dimm 1.0 a el=63

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph SR band exp #frames disturb notes
20101127_013243 AO816 8.0 79 4 -1.00 0.55 092604 1 400 990 0.5 0.6 3 363 56.1 H 10 1000 ONSKY  
20101127_013407 AO816 8.0 78 4 -1.00 0.53 092604 1 400 990 0.5 0.6 3 362 -1.0 ? -1 -1 ONSKY  
20101127_013425 AO816 8.0 78 4 -1.00 0.58 092604 1 400 990 0.5 0.6 3 363 55.9 H 10 1000 ONSKY  
20101127_013631 AO816 8.0 78 4 -1.00 0.54 092604 1 400 990 0.5 0.6 3 363 60.4 H 10 1000 ONSKY  
20101127_014108 AO816 8.0 78 4 1.15 0.53 092604 1 400 990 0.6 0.6 3 359 50.9 H 10 1000 ONSKY  
20101127_014229 AO816 8.1 78 5 -1.00 0.70 092604 1 400 990 0.6 0.6 3 351 39.9 H 10 1000 ONSKY  
20101127_014346 AO816 8.1 78 5 0.93 0.46 092604 1 400 990 0.6 0.6 3 356 51.6 H 10 1000 ONSKY  

014500 Mirror ventilation is off

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph SR band exp #frames disturb notes
20101127_014733 AO816 8.0 78 5 -1.00 0.31 092604 1 400 990 0.5 0.6 3 363 79.0 H 10 1000 ONSKY  
20101127_014852 AO816 8.0 77 5 -1.00 0.37 092604 1 400 990 0.5 0.6 3 362 76.8 H 10 1000 ONSKY  
20101127_015028 AO816 8.0 77 4 -1.00 0.33 092604 1 400 990 0.5 0.6 3 362 75.5 H 10 1000 ONSKY  
20101127_015152 AO816 8.0 77 4 -1.00 0.35 092604 1 400 990 0.5 0.6 3 361 72.9 H 10 1000 ONSKY  
20101127_015319 AO816 8.0 77 5 1.05 0.42 092604 1 400 990 0.5 0.6 3 359 69.1 H 10 1000 ONSKY  
20101127_015908 AO816 8.1 76 5 -1.00 0.41 092604 1 400 990 0.6 0.9 3 350 73.8 H 10 1000 ONSKY AG
20101127_020029 AO816 8.1 76 4 0.99 0.40 092604 1 400 990 0.6 0.9 3 348 74.3 H 10 1000 ONSKY AG
20101127_020148 AO816 8.1 76 5 0.97 0.38 092604 1 400 990 0.6 0.9 3 347 77.0 H 10 1000 ONSKY AG

20101127_020710 Abbassato un po il gain ottimale nella procedura automatica

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph SR band exp #frames disturb notes
20101127_020710 AO816 8.1 75 5 0.90 0.35 092604 1 400 990 0.3 0.6 3 350 74.5 H 10 1000 ONSKY  
20101127_020828 AO816 8.1 75 5 1.01 0.32 092604 1 400 990 0.6 0.8 3 346 90.5 H 10 1000 ONSKY AG
20101127_020944 AO816 8.1 75 5 -1.00 0.37 092604 1 400 990 0.6 0.8 3 344 90.5 H 10 1000 ONSKY AG
20101127_021101 AO816 8.1 75 5 -1.00 0.33 092604 1 400 990 0.6 0.8 3 343 86.8 H 10 1000 ONSKY AG

AO54 R=8.8

021415 puntamento
022215 loop closed
022600 Dimm 0.7 a el=54

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph SR band exp #frames disturb notes
20101127_022517 AO54 9.0 72 5 0.74 0.27 092604 1 400 990 0.5 0.7 3 154 80.0 H 10 1000 ONSKY  
20101127_022652 AO54 9.0 73 5 0.73 0.28 092604 1 400 990 0.5 0.7 3 154 83.5 H 10 1000 ONSKY  
20101127_022812 AO54 9.0 73 4 0.66 0.28 092604 1 400 990 0.5 0.7 3 154 83.8 H 10 1000 ONSKY  
20101127_023450 AO54 9.0 74 4 -1.00 0.24 092604 1 400 990 0.6 0.9 3 150 89.0 H 10 1000 ONSKY  
20101127_023610 AO54 9.0 74 5 -1.00 0.28 092604 1 400 990 0.6 0.9 3 149 88.2 H 10 1000 ONSKY  
20101127_023735 AO54 9.0 74 5 -1.00 0.28 092604 1 400 990 0.6 0.9 3 151 91.2 H 10 1000 ONSKY  
20101127_024308 AO54 9.0 74 5 -1.00 0.26 092604 1 400 990 0.4 0.6 3 147 84.2 H 10 1000 ONSKY  

si perde la stella, si riprendono degli open loop per dirimere la questione misura del seeing

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph SR band exp #frames disturb notes
20101127_025226 AO54 8.9 75 5 -1.00 0.10 092604 1 400 990 0.0 0.0 3 158 7.2 H 50 200 ONSKY  
20101127_025252 AO54 8.9 75 5 -1.00 0.09 092604 1 400 990 0.0 0.0 3 157 7.6 H 50 600 ONSKY  
20101127_025403 AO54 8.9 76 5 -1.00 0.07 092604 1 400 990 0.0 0.0 3 158 4.5 H 50 600 ONSKY  
20101127_025518 AO54 8.9 76 5 0.64 0.01 092604 1 400 990 0.0 0.0 3 164 4.6 H 50 600 ONSKY  

Il 20101127_025518 ha un FWHM in H di 0.18arcsec che con L0=40m vuol dire un seeing di 0.4arcsec, rispetto a 0.64 misurato dal DIMM e 0.28 misurato da FQP

Ora si fa una misura a loop chiuso con offset delle slitte e offload modes staccato

025900 tilt di 0.33 arcsec

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph SR band exp #frames disturb notes
20101127_025816 AO54 9.1 76 5 -1.00 0.23 092604 1 400 990 0.2 0.3 3 137 62.5 H 10 600 ONSKY  

ee = getaoelab('20101127_024308')
ff = getaoelab('20101127_025816')
mirave = (ee->modalpositions())->time_average()
tipave = (ff->modalpositions())->time_average()
print, 2 * 4 * (mirave[0] - tipave[0]) / 8.22 /4.848d-6

The output of the computation is 0.2" vs an input tilt of 0.33"

Ma nel frattempo si e' spostato l'esapodo. Va rifatta a modino.

AO37 R=9.8

030200 puntamento
031100 sceglie bin1 perche' misura 9.1

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph SR band exp #frames disturb notes
20101127_031410 AO37 10.4 84 3 -1.00 0.22 092604 1 400 990 0.6 0.8 3 41 84.9 H 50 200 ONSKY  
20101127_031444 AO37 10.4 84 3 -1.00 0.25 092604 1 400 990 0.6 0.8 3 39 81.2 H 50 200 ONSKY  
20101127_031511 AO37 10.5 83 4 -1.00 0.22 092604 1 400 990 0.6 0.8 3 37 91.9 H 50 200 ONSKY  

032500 la bcu non manda piu' le slopes, si cambia stella e si riaccende

AO892 R=10.

034000 loop chiuso automatico

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph SR band exp #frames disturb notes
20101127_034418 AO892 10.6 68 6 0.80 0.39 180534 2 150 991 1.0 1.2 3 143 57.3 H 150 70 ONSKY  
20101127_034442 AO892 10.6 67 6 0.87 0.38 180534 2 150 991 1.0 1.2 3 144 57.6 H 150 70 ONSKY  
20101127_034504 AO892 10.6 67 6 0.87 0.40 180534 2 150 991 1.0 1.2 3 146 57.2 H 150 70 ONSKY  

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph SR band exp #frames disturb notes
20101127_034806 AO892 10.5 67 6 0.72 0.31 180534 2 150 991 1.0 1.2 3 156 57.0 H 150 70 ONSKY  
20101127_034826 AO892 10.5 67 6 0.74 0.34 180534 2 150 991 1.0 1.2 3 157 57.2 H 150 70 ONSKY  
20101127_034913 AO892 10.5 67 6 0.72 0.31 180534 2 150 991 1.0 1.2 3 160 0.0 H 150 70 ONSKY ERRORE SCARTARE
20101127_034931 AO892 10.5 66 6 0.71 0.41 180534 2 150 991 1.0 1.2 3 160 47.3 H 150 70 ONSKY  
20101127_035239 AO892 10.4 66 6 0.83 0.52 180534 2 150 991 1.2 1.2 3 168 45.5 H 150 70 ONSKY  
20101127_035258 AO892 10.4 66 6 0.72 0.55 180534 2 150 991 1.2 1.2 3 168 39.7 H 150 70 ONSKY  
20101127_035321 AO892 10.4 66 7 0.70 0.55 180534 2 150 991 1.2 1.2 3 169 35.9 H 150 70 ONSKY  
20101127_035654 AO892 10.8 65 7 0.78 0.49 180534 2 150 991 0.8 1.2 3 124 51.7 H 150 70 ONSKY  
20101127_035714 AO892 10.8 65 7 0.73 0.50 180534 2 150 991 0.8 1.2 3 124 49.6 H 150 70 ONSKY  
20101127_035734 AO892 10.8 65 6 0.69 0.51 180534 2 150 991 0.8 1.2 3 124 50.3 H 150 70 ONSKY  
20101127_035752 AO892 10.8 65 6 0.74 0.59 180534 2 150 991 0.8 1.2 3 124 39.4 H 150 70 ONSKY  
20101127_035908 AO892 10.8 64 7 0.75 0.73 180534 2 150 991 0.8 1.2 3 124 33.7 H 150 70 ONSKY  
20101127_040017 AO892 10.8 64 7 0.77 0.46 180534 2 150 991 0.8 1.2 3 123 53.4 H 150 70 ONSKY  

Andiamo ad una 11.8

AO899 R11.8

Ma H=4 e alla fine si misura una magnitudine 7. Si prova il tracking vicino allo zenith

Si riprova con il test della calibrazione dei modi
042233 loop chiuso, no offload all-esapodo
042259 tilt 0.33 arcsec
042300 loop chiuso, no offload all-esapodo

Rifacendo come sopra con 042233 e 042300 il tilt applicato allo specchio misurato da modalpositions e' 0.2 contro 0.33 realmente applicato in cielo Se abbiamo un fattore 1.66 di errore nella misura dell'ampiezza dei modi questo ci affetta la stima del seeing di un fattore 1.66 ^ 6/5 = 1.8 Il olmodes.seeing deve essere corretto con un fattore 1.8

Il loop e' passato chiuso a 87 54' gradi di elevazione

Da 042346 a 043437 sono presi durante la rotazione veloce del telescopio Il telescopio ha mandato uno stop a 87 gradi, poi il loop e' stato richuso a mano

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph SR band exp #frames disturb notes
20101127_042406 AO899 8.0 87 7 -1.00 0.39 092604 1 400 990 0.7 0.9 3 367 0.0 H 3 1000 ONSKY  
20101127_042523 AO899 8.0 87 6 -1.00 0.35 092604 1 400 990 0.7 0.9 3 359 84.5 H 3 1000 ONSKY  
20101127_042641 AO899 7.9 87 5 -1.00 0.26 092604 1 400 990 0.7 0.9 3 394 2.7 H 3 1000 ONSKY  
20101127_042936 AO899 8.0 88 8 -1.00 0.25 092604 1 400 990 0.4 0.8 3 360 64.6 H 3 1000 ONSKY  
20101127_043055 AO899 8.1 88 8 -1.00 0.25 092604 1 400 990 0.6 0.9 3 350 83.5 H 3 1000 ONSKY  
20101127_043310 AO899 8.1 88 4 -1.00 0.25 092604 1 400 990 0.6 0.9 3 339 77.4 H 3 1000 ONSKY  
20101127_043437 AO899 8.1 88 6 -1.00 0.25 092604 1 400 990 0.6 0.9 3 334 28.1 H 3 1000 ONSKY  

AO107 R=12.1

045100 puntamento
045500 problema al telescopio
050020 si ripunta, ma ci sono ancora probl. di tel
050800 tel pronto

Mag stimata 12.0 dall'AcquireRef
05115 star acquired DIMM=0.6

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph SR band exp #frames disturb notes
20101127_051358 AO107 11.9 79 5 0.68 0.35 180534 2 150 845 1.4 1.5 3 51 36.8 H 500 20 ONSKY  
20101127_051415 AO107 12.0 79 4 0.64 0.37 180534 2 150 845 1.4 1.5 3 46 -1.0 ? -1 -1 ONSKY  
20101127_051436 AO107 12.1 79 5 0.64 0.36 180534 2 150 845 1.4 1.5 3 43 45.3 H 500 20 ONSKY  
20101127_051455 AO107 12.1 79 4 0.66 0.43 180534 2 150 845 1.4 1.5 3 43 45.3 H 500 20 ONSKY  
20101127_051848 AO107 11.9 79 5 0.69 0.41 180534 2 150 845 0.6 1.7 3 51 40.9 H 500 20 ONSKY AG
20101127_051908 AO107 11.9 79 5 0.69 0.37 180534 2 150 845 0.6 1.7 3 51 47.3 H 500 20 ONSKY AG
20101127_051925 AO107 11.9 79 3 0.65 0.36 180534 2 150 845 0.6 1.7 3 52 41.2 H 500 20 ONSKY AG
20101127_052008 AO107 11.9 79 4 0.70 0.37 180534 2 150 845 0.6 1.7 3 53 47.4 H 500 20 ONSKY  
20101127_052030 AO107 11.8 79 4 0.70 0.38 180534 2 150 845 0.6 1.7 3 54 41.5 H 500 20 ONSKY  

Siamo controvento. Andiamo su una stella con il vento in poppa, che funziona sempre meglio

AO1068 R=12.1

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph SR band exp #frames disturb notes
20101127_053420 AO1068 12.1 72 8 -1.00 0.36 180534 2 150 894 1.0 1.4 3 41 38.2 H 500 20 ONSKY  
20101127_053438 AO1068 12.2 72 7 -1.00 0.45 180534 2 150 894 1.0 1.4 3 38 35.6 H 500 20 ONSKY  
20101127_053502 AO1068 12.3 72 7 -1.00 0.40 180534 2 150 894 1.0 1.4 3 35 23.0 H 500 20 ONSKY  
20101127_053534 AO1068 12.1 72 8 -1.00 0.40 180534 2 150 894 1.0 1.4 3 39 33.9 H 500 20 ONSKY  
20101127_053550 AO1068 12.2 72 7 -1.00 0.49 180534 2 150 894 1.0 1.4 3 37 33.2 H 500 20 ONSKY  
20101127_053907 AO1068 12.3 72 8 -1.00 0.35 180534 2 150 894 0.4 1.2 3 35 50.1 H 500 20 ONSKY  
20101127_053928 AO1068 12.4 72 8 0.66 0.44 180534 2 150 894 0.4 1.2 3 32 41.5 H 500 20 ONSKY  
20101127_054004 AO1068 12.3 72 8 0.63 0.31 180534 2 150 894 0.4 1.2 3 33 46.6 H 500 20 ONSKY  
20101127_054033 AO1068 12.3 72 8 0.63 0.36 180534 2 150 894 0.4 1.2 3 34 44.3 H 500 20 ONSKY  
20101127_054106 AO1068 12.4 72 8 0.67 0.35 180534 2 150 894 0.4 1.2 3 30 43.3 H 500 20 ONSKY  

054200 l'antidrift era staccato e il drift del ccd39 ha causato un loopFail con conseguente Recover. Ora si attacca l'antidrift

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph SR band exp #frames disturb notes
20101127_054840 AO1068 12.0 72 7 0.58 0.27 180534 2 150 953 0.5 1.2 3 42 54.8 H 300 40 ONSKY  
20101127_054859 AO1068 12.0 72 7 0.60 0.29 180534 2 150 953 0.5 1.2 3 42 45.9 H 300 40 ONSKY  
20101127_054916 AO1068 12.0 72 8 0.61 0.30 180534 2 150 953 0.5 1.2 3 43 57.1 H 300 40 ONSKY  
20101127_055105 AO1068 12.0 72 8 -1.00 0.35 180534 2 150 953 0.5 1.2 3 41 51.7 H 300 40 ONSKY  
20101127_055148 AO1068 12.0 72 8 -1.00 0.35 180534 2 150 953 0.5 1.2 3 41 51.4 H 300 40 ONSKY  

Installata la ND

AO245 R=8.9 + ND

064400 DIMM 0.9" el=33

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph SR band exp #frames disturb notes
20101127_065324 AO245 13.4 63 9 1.03 0.43 180534 2 150 444 0.9 1.9 3 25 27.5 H 100 100 ONSKY manual gain
20101127_065351 AO245 13.3 63 9 1.01 0.39 180534 2 150 444 0.9 1.9 3 26 26.3 H 100 100 ONSKY manual gain
20101127_065413 AO245 13.3 63 9 1.01 0.34 180534 2 150 444 0.9 1.9 3 27 27.5 H 100 100 ONSKY manual gain
20101127_065939 AO245 13.2 64 9 1.13 0.40 180534 2 150 444 1.5 1.5 3 29 18.6 H 100 100 ONSKY auto gain
20101127_070004 AO245 13.2 64 8 1.17 0.41 180534 2 150 444 1.5 1.5 3 30 21.3 H 100 100 ONSKY auto gain
20101127_070026 AO245 13.2 64 8 1.05 0.46 180534 2 150 444 1.5 1.5 3 31 18.8 H 100 100 ONSKY auto gain
20101127_070135 AO245 13.1 65 8 1.05 0.36 180534 2 150 444 0.9 1.9 3 32 24.0 H 100 100 ONSKY manual gain
20101127_070157 AO245 13.1 65 8 1.10 0.37 180534 2 150 444 0.9 1.9 3 34 25.5 H 100 100 ONSKY manual gain
20101127_070220 AO245 13.0 65 8 1.12 0.42 180534 2 150 444 0.9 1.9 3 34 25.6 H 100 100 ONSKY manual gain
20101127_070506 AO245 13.2 65 8 1.34 0.32 180534 2 150 444 0.6 1.6 3 28 26.3 H 100 100 ONSKY AG
20101127_070537 AO245 13.2 65 8 1.07 0.38 180534 2 150 444 0.6 1.6 3 30 27.3 H 100 100 ONSKY AG
20101127_070559 AO245 13.2 66 8 1.21 0.38 180534 2 150 444 0.6 1.6 3 31 24.3 H 100 100 ONSKY AG
20101127_070657 AO245 13.0 66 9 1.26 0.06 180534 2 150 444 0.0 0.0 3 34 1.3 H 1000 30 ONSKY OL
20101127_070748 AO245 13.1 66 9 1.38 0.04 180534 2 150 444 0.0 0.0 3 33 2.4 H 1000 30 ONSKY OL

070657 ha una FWHM di 0.38" in H che vuol dire seeing=0.67

070620 ha una FWHM di 0.48" in H

Dal 071218 il DIMM e' alla giusta elevazione e ritorna a dare 0.7" come

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph SR band exp #frames disturb notes
20101127_071218 AO245 13.0 67 9 0.65 0.37 180534 2 150 444 0.9 1.8 3 35 21.1 H 100 30 ONSKY AG
20101127_071239 AO245 13.0 67 9 0.65 0.34 180534 2 150 444 0.9 1.8 3 35 20.1 H 100 30 ONSKY AG
20101127_071300 AO245 13.1 67 9 0.63 0.33 180534 2 150 444 0.9 1.8 3 34 22.1 H 100 30 ONSKY  
20101127_071726 AO245 13.2 68 9 0.67 0.33 180534 2 150 300 1.1 2.1 3 46 26.7 H 100 30 ONSKY  
20101127_071746 AO245 13.2 68 9 0.68 0.36 180534 2 150 300 1.1 2.1 3 45 27.0 H 100 30 ONSKY  
20101127_071802 AO245 13.2 68 9 0.75 0.35 180534 2 150 300 1.1 2.1 3 43 26.1 H 100 30 ONSKY  

073200 c'e' il readout speed troppo veloce per questo framerate

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph SR band exp #frames disturb notes
20101127_072747 AO245 13.7 70 8 -1.00 0.43 180534 2 150 445 0.6 2.0 3 18 31.8 H 100 100 ONSKY  
20101127_072808 AO245 13.5 70 8 -1.00 0.40 180534 2 150 445 0.6 2.0 3 23 29.9 H 100 100 ONSKY  
20101127_072832 AO245 13.5 70 8 -1.00 0.42 180534 2 150 445 0.6 2.0 3 22 27.5 H 100 100 ONSKY  
20101127_073116 AO245 13.4 71 8 0.82 0.44 180534 2 150 445 0.6 2.0 3 24 26.9 H 100 100 ONSKY  
20101127_073137 AO245 13.5 71 8 0.81 0.49 180534 2 150 445 0.6 2.0 3 23 24.8 H 100 100 ONSKY  
20101127_073200 AO245 13.5 71 8 0.78 0.44 180534 2 150 445 0.6 2.0 3 22 28.3 H 100 100 ONSKY  
20101127_073512 AO245 13.5 72 7 0.84 0.50 180534 2 150 300 1.0 2.0 3 35 25.8 H 100 100 ONSKY  
20101127_073532 AO245 13.5 72 8 0.76 0.42 180534 2 150 300 1.0 2.0 3 35 28.3 H 100 100 ONSKY  
20101127_073600 AO245 13.5 72 8 0.76 0.40 180534 2 150 300 1.0 2.0 3 35 31.4 H 100 100 ONSKY  

070657 ha una FWHM di 0.38" in H che vuol dire seeing=0.67

070620 ha una FWHM di 0.48" in H

Dal 071218 il DIMM e' alla giusta elevazione e ritorna a dare 0.7" come

AO836 R 10.7

073700 Puntamento
??? L'AO stima male il numero di fotoni e rende errore. L'ottica attiva va in errore
083500 Ora riabbiamo la stella ma ci sono pochi fotoni. Siamo finiti a bin 4
084000 DIMM 0.7 el=57

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph SR band exp #frames disturb notes
20101127_084821 AO836 14.6 58 4 0.80 0.36 075552 3 66 265 1.1 1.8 6 31 20.1 H 300 30 ONSKY  
20101127_084844 AO836 14.3 58 6 0.74 0.33 075552 3 66 265 1.1 1.8 6 41 20.8 H 300 30 ONSKY  
20101127_084905 AO836 14.4 58 4 0.72 0.33 075552 3 66 265 1.1 1.8 6 36 24.4 H 300 30 ONSKY  
20101127_085140 AO836 14.5 57 4 0.72 0.32 075552 3 66 265 1.1 1.8 6 34 22.9 H 300 212 ONSKY  
20101127_085306 AO836 14.4 57 4 0.72 0.28 075552 3 66 265 1.1 1.8 6 39 25.1 H 300 30 ONSKY  
20101127_085326 AO836 14.4 57 3 0.71 0.47 075552 3 66 265 1.1 1.8 6 37 17.6 H 300 30 ONSKY  
20101127_085614 AO836 14.5 56 5 0.68 0.64 075552 3 66 265 1.3 2.8 6 35 12.6 H 300 30 ONSKY  
20101127_085633 AO836 14.8 56 4 1.00 0.83 075552 3 66 265 1.3 2.8 6 26 7.6 H 300 30 ONSKY  
20101127_085657 AO836 14.4 56 4 1.08 0.56 075552 3 66 265 1.3 2.8 6 38 13.7 H 300 30 ONSKY  
20101127_085758 AO836 14.4 56 6 0.84 0.48 075552 3 66 265 1.3 3.0 6 36 -1.0 ? -1 -1 ONSKY  
20101127_085818 AO836 14.5 56 6 0.78 0.42 075552 3 66 265 1.3 3.0 6 35 -1.0 ? -1 -1 ONSKY  
20101127_085840 AO836 14.4 56 7 0.84 0.74 075552 3 66 265 1.3 3.0 6 37 9.7 H 300 30 ONSKY  
20101127_085900 AO836 14.4 56 5 0.90 0.43 075552 3 66 265 1.3 3.0 6 38 19.7 H 300 30 ONSKY  
20101127_085918 AO836 14.4 56 5 0.94 0.37 075552 3 66 265 1.3 3.0 6 37 22.2 H 300 30 ONSKY  
20101127_085943 AO836 14.3 55 7 0.75 0.46 075552 3 66 265 1.3 2.7 6 39 20.3 H 300 30 ONSKY  
20101127_090006 AO836 14.3 55 4 0.75 0.43 075552 3 66 265 1.3 2.7 6 39 23.1 H 300 30 ONSKY  
20101127_090026 AO836 14.4 55 4 0.80 0.40 075552 3 66 265 1.3 2.7 6 38 22.0 H 300 30 ONSKY  
20101127_090123 AO836 14.3 55 3 0.69 0.07 075552 3 66 265 0.0 0.0 6 40 -1.0 ? -1 -1 ONSKY Error
20101127_090220 AO836 14.5 55 4 0.73 0.08 075552 3 66 265 0.0 0.0 6 33 1.9 H 1000 30 ONSKY  
20101127_090259 AO836 14.6 55 4 0.80 0.09 075552 3 66 265 0.0 0.0 6 30 1.5 H 1000 30 ONSKY  

L'open loop ha FWHM 0.27" in H cioe' seeing=0.52" con L0=50 contro 0.73 del DIMM e

AO911

090600 Puntamento
092000 Viene fuori 14.2
092000 DIMM 0.6 el = ?

Too bright, prendiamone un'altra!

AO248

092500 Primario rippato! Panic error
094300 Si misura una 16.1, Skippa, stop
095300 Ancora problemi, non fa il dark. Nel frattempo resettano il rotatore
095900 Era un bug nella tabella Ora ci siamo ma il primario fa una splendida psf a ciambella
102100 Il telescopio si e' ripreso, si fa il presetAO
102700 Si chiude per un attimo, ma ci sono troppo pochi fotoni, R=17.2

AO921 R=11.9

E' nuvolo, non si riesce piu' a lavorare

AO301 R=6.3

Open loop offset test

TT Mode test

11:47:00

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph SR band exp #frames disturb notes
20101127_115526 TTtest 11.3 80 9 -1.00 Inf 235002 4 5 701 0.0 0.0 6 478 0.5 H 200 50 ONSKY  
20101127_115542 TTtest 11.3 80 8 -1.00 Inf 235002 4 5 701 0.0 0.0 6 497 0.6 H 200 50 ONSKY  
20101127_115559 TTtest 11.2 80 9 -1.00 Inf 235002 4 5 701 0.0 0.0 6 544 0.6 H 200 50 ONSKY  
20101127_120054 TTtest 11.2 79 9 -1.00 Inf 235002 4 5 701 0.1 0.2 6 516 1.0 H 200 50 ONSKY  
20101127_120737 TTtest 11.3 78 8 -1.00 0.52 110053 4 10 701 0.7 1.1 6 468 -1.0 ? -1 -1 ONSKY  
20101127_120753 TTtest 11.4 78 9 -1.00 0.32 110053 4 10 701 0.7 1.1 6 449 1.5 H 200 50 ONSKY  
20101127_120820 TTtest 11.5 78 10 -1.00 0.44 110053 4 10 701 0.7 1.1 6 422 1.8 H 200 50 ONSKY  

121850 Si rifa con lo specchio un spianato bene

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph SR band exp #frames disturb notes
20101127_122025 TTtest 11.5 76 11 -1.00 Inf 235002 4 5 701 0.8 1.2 6 410 1.7 H 200 50 ONSKY  
20101127_122046 TTtest 11.5 76 10 -1.00 Inf 235002 4 5 701 0.8 1.2 6 425 1.1 H 100 50 ONSKY  
20101127_122102 TTtest 11.4 76 11 -1.00 Inf 235002 4 5 701 0.8 1.2 6 463 1.7 H 100 100 ONSKY  
20101127_122122 TTtest 11.3 76 11 -1.00 Inf 235002 4 5 701 0.8 1.2 6 474 2.2 H 100 100 ONSKY  
20101127_122142 TTtest 11.3 76 11 -1.00 Inf 235002 4 5 701 0.0 0.0 6 485 1.5 H 100 100 ONSKY  
20101127_122201 TTtest 11.3 76 10 -1.00 Inf 235002 4 5 701 0.0 0.0 6 491 1.2 H 100 100 ONSKY  
20101127_122220 TTtest 11.3 76 10 -1.00 Inf 235002 4 5 701 0.0 0.0 6 488 1.3 H 100 100 ONSKY  

Off axis test

Non funziona, abbiamo la densita' che svignetta tutto quanto. Si chiude

-- EnricoPinna - 27 Nov 2010