H18:00 si punta

AO794

Wref RA Dec S type B V R I J H notes
AO794 22:40:52.472 +20:49:22.21 K2 9.63 8.23 7.38   5.81 5.12 BD+20 5203

Los pecchio va spesso in safeskip Prendiamo OL per misurare il seeing

TrackNo RefStar Mag El Wind DIMM Rec bin #mod freq gain mod nph SR band exp #frames disturb notes
20101126_012742 AO794 8.8 78 11 NaN 092604 1 400 990 0.0 0.0 3 181 -1.0 ? -1 -1 ONSKY  
20101126_012759 AO794 8.6 78 11 NaN 092604 1 400 990 0.0 0.0 3 211 -1.0 ? -1 -1 ONSKY  
20101126_012816 AO794 8.8 78 10 NaN 092604 1 400 990 0.0 0.0 3 183 0.2 H 1000 30 ONSKY FWHM 1.25 Hband
20101126_012851 AO794 9.0 78 11 NaN 092604 1 400 990 0.0 0.0 3 144 0.6 H 1000 30 ONSKY  

Closed loop con qualche problema di safeskip...

Misuriamo un FWHM di 1.23 in H band che con outerscale 20-50m significa 1.8-2.0" di seeing.
TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph SR band exp #frames disturb notes
20101126_014023 AO794 8.3 78 11 NaN 1.48 092604 1 400 990 1.2 1.4 3 277 17.3 H 70 150 ONSKY  
20101126_014048 AO794 8.3 78 11 NaN 1.46 092604 1 400 990 1.2 1.4 3 279 14.5 H 70 150 ONSKY  
20101126_014118 AO794 8.3 78 12 NaN 1.40 092604 1 400 990 1.2 1.4 3 286 18.6 H 30 300 ONSKY  
20101126_014151 AO794 8.4 78 10 NaN 1.57 092604 1 400 990 1.2 1.4 3 265 12.3 H 30 300 ONSKY  
20101126_014223 AO794 8.5 78 11 NaN 1.73 092604 1 400 990 1.2 1.4 3 236 12.3 H 30 300 ONSKY  

20101126_012816 vs 20101126_014151

  • ol_vs_cl_18arcse.jpg:
    ol_vs_cl_18arcse.jpg

  • ol_vs_cl_18arcse_plot.jpg:
    ol_vs_cl_18arcse_plot.jpg
Qui tutti i loop hanno molto skipframe
TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph SR band exp #frames disturb notes
20101126_020552 AO794 8.5 77 11 NaN 1.63 092604 1 400 990 0.8 1.0 3 233 2.7 H 300 117 ONSKY  
20101126_020641 AO794 8.7 77 10 NaN 1.88 092604 1 400 990 0.8 1.0 3 197 1.8 H 300 30 ONSKY  
20101126_020700 AO794 8.6 77 11 NaN 1.62 092604 1 400 990 0.8 1.0 3 218 1.4 H 300 30 ONSKY  
20101126_020716 AO794 8.9 77 10 NaN 1.25 092604 1 400 990 0.8 1.0 3 164 1.0 H 300 30 ONSKY  

AO704 TEST ACQUISITION @ low elevation

Wref RA Dec S type B V R I J H notes
AO704 21:34:36.393 +02:15:27.17 K0 10.02 8.63 7.83   6.39 5.77 HD 205357

STAR ACQUIRED @50deg elevation


h19:33 blocco del message demon del secondario

tirando giu' quello del secondario si blocca anche quello del W

problema con il nostro rirotatore che andava negativo


AO777 @elevation=30

Wref RA Dec S type B V R I J H notes
AO767 22:08:40.485 +00:20:16.92 K2 8.91 7.77 7.07   5.63 5.09 HD 210185

Acquisition OK!

A BIN1 non riusciamo a stabilizzare la posizione della pup al livello di 0.1 pix, perche' il seeing a questa altezza sul guider vinee 2.5"

Mettiamo il BIN2 e chiudiamo subito il loop

Optical loop data NON funziona piu'....

Prendiamo un loop per stimare il seeing= 2.5" (airmass 2)

AO74

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph SR band exp #frames disturb notes
20101126_051543 AO74 8.0 69 13 NaN 1.07 092604 1 400 990 0.6 1.1 3 361 -1.0 ? -1 -1 ONSKY  
20101126_051600 AO74 8.0 69 16 NaN 1.01 092604 1 400 990 0.6 1.1 3 367 29.5 H 25 200 ONSKY  
20101126_051626 AO74 8.1 69 15 NaN 1.00 092604 1 400 990 0.6 1.1 3 355 16.3 H 25 400 ONSKY  
20101126_051706 AO74 8.1 69 15 NaN 1.12 092604 1 400 990 0.6 1.1 3 339 11.3 H 25 400 ONSKY  
20101126_051745 AO74 8.2 69 15 NaN 1.23 092604 1 400 990 0.6 1.1 3 305 8.3 H 25 400 ONSKY  
20101126_052040 AO74 8.0 69 13 NaN 0.99 092604 1 400 990 0.6 1.1 3 362 18.4 H 25 400 ONSKY  
20101126_052119 AO74 8.1 69 15 NaN 1.15 092604 1 400 990 0.6 1.1 3 351 6.6 H 25 400 ONSKY  
20101126_052208 AO74 8.0 70 15 NaN 0.92 092604 1 400 990 0.6 1.1 3 378 19.6 H 25 400 ONSKY - long stop of 177 frames at frame 1190
20101126_052405 AO74 8.0 70 13 NaN 1.13 092604 1 400 990 1.4 1.5 3 368 53.8 H 10 400 ONSKY  
20101126_052441 AO74 8.1 70 16 NaN 1.34 092604 1 400 990 1.4 1.5 3 346 28.4 H 10 1000 ONSKY  
20101126_052602 AO74 8.0 70 16 NaN 1.16 092604 1 400 990 1.4 1.5 3 371 35.6 H 10 1000 ONSKY  
20101126_052743 AO74 8.0 70 11 NaN 1.16 092604 1 400 990 1.4 1.5 3 368 38.2 H 10 1000 ONSKY  
20101126_054041 AO74 8.1 71 14 NaN 1.33 092604 1 400 990 1.1 1.3 3 331 19.2 H 10 1000 ONSKY  
20101126_054205 AO74 8.0 71 14 NaN 0.98 092604 1 400 990 1.1 1.3 3 384 42.8 H 10 1000 ONSKY - long stop of 26 frames at frame 3964
20101126_054332 AO74 8.0 71 16 NaN 1.18 092604 1 400 990 1.1 1.3 3 363 25.5 H 10 1000 ONSKY  
20101126_054530 AO74 8.0 71 16 NaN 1.07 092604 1 400 990 1.1 1.3 3 379 40.9 H 10 1000 ONSKY  
20101126_054828 AO74 8.0 72 14 NaN 1.30 092604 1 400 990 1.4 1.4 3 358 22.3 H 10 1000 ONSKY  
20101126_054949 AO74 8.1 72 14 NaN 1.35 092604 1 400 990 1.4 1.4 3 344 23.2 H 10 1000 ONSKY  
20101126_055109 AO74 8.1 72 15 NaN 1.40 092604 1 400 990 1.4 1.4 3 329 29.1 H 10 1000 ONSKY  
20101126_060157 AO74 8.3 72 13 NaN 0.06 092604 1 400 990 0.0 0.0 3 289 0.4 H 1000 30 ONSKY  
20101126_060240 AO74 8.3 72 13 NaN 0.05 092604 1 400 990 0.0 0.0 3 281 0.4 H 1000 30 ONSKY  
20101126_060317 AO74 8.4 72 14 NaN 0.05 092604 1 400 990 0.0 0.0 3 255 0.2 H 1000 30 ONSKY  
20101126_060849 AO74 8.1 72 14 NaN 1.33 092604 1 400 990 1.4 1.4 3 336 -1.0 ? -1 -1 ONSKY  
20101126_060913 AO74 8.0 72 14 NaN 1.21 092604 1 400 990 1.4 1.4 3 361 -1.0 ? -1 -1 ONSKY  
20101126_060935 AO74 8.1 72 13 NaN 1.26 092604 1 400 990 1.4 1.4 3 354 -1.0 ? -1 -1 ONSKY  
20101126_060955 AO74 8.1 72 14 NaN 1.37 092604 1 400 990 1.4 1.4 3 331 27.2 H 10 1000 ONSKY  
20101126_061116 AO74 8.0 72 13 NaN 1.06 092604 1 400 990 1.4 1.4 3 382 48.5 H 10 1000 ONSKY  
20101126_061834 AO74 7.9 72 13 NaN 0.87 092604 1 400 990 1.2 1.9 3 400 54.0 H 10 1000 ONSKY  
20101126_061957 AO74 7.9 71 13 NaN 0.85 092604 1 400 990 1.2 1.9 3 404 69.2 H 10 1000 ONSKY  
20101126_062116 AO74 8.0 71 13 NaN 1.08 092604 1 400 990 1.2 1.9 3 376 43.9 H 10 1000 ONSKY  
20101126_062520 AO74 7.9 71 12 NaN 0.87 092604 1 400 990 1.1 1.4 3 403 57.7 H 10 1000 ONSKY  
20101126_062644 AO74 7.9 71 13 NaN 0.88 092604 1 400 990 1.1 1.4 3 400 60.8 H 10 1000 ONSKY  
20101126_062802 AO74 7.9 71 12 NaN 0.80 092604 1 400 990 1.1 1.4 3 410 73.0 H 10 1000 ONSKY  
20101126_063301 AO74 8.0 71 13 NaN 0.05 092604 1 400 990 0.0 0.0 3 380 0.3 H 1000 30 ONSKY  
20101126_063346 AO74 8.0 71 13 NaN 0.05 092604 1 400 990 0.0 0.0 3 373 0.3 H 1000 30 ONSKY  
20101126_063423 AO74 8.0 71 13 NaN 0.04 092604 1 400 990 0.0 0.0 3 368 0.3 H 1000 30 ONSKY - long stop of 50 frames at frame 3797
20101126_065210 AO74 7.9 69 14 NaN 0.81 092604 1 400 990 1.0 1.4 3 393 66.6 H 10 1000 ONSKY  
20101126_065330 AO74 8.0 69 12 NaN 0.97 092604 1 400 990 1.0 1.4 3 379 51.0 H 10 1000 ONSKY  
20101126_065450 AO74 8.0 68 14 NaN 1.08 092604 1 400 990 1.0 1.4 3 367 48.9 H 10 1000 ONSKY  

AO78 R=8.5

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph SR band exp #frames disturb notes
20101126_073042 AO78 9.4 67 12 NaN 1.29 092604 1 400 990 1.3 1.5 3 107 -1.0 ? -1 -1 ONSKY  
20101126_073100 AO78 9.4 67 9 NaN 1.34 092604 1 400 990 1.3 1.5 3 105 30.3 H 50 200 ONSKY  
20101126_073128 AO78 9.5 67 12 NaN 1.58 092604 1 400 990 1.3 1.5 3 92 23.2 H 50 200 ONSKY  
20101126_073157 AO78 9.4 67 12 NaN 1.40 092604 1 400 990 1.3 1.5 3 99 23.7 H 50 200 ONSKY  
20101126_074135 AO78 9.9 65 11 NaN 0.05 092604 1 400 990 0.0 0.0 3 66 0.2 H 2000 15 ONSKY  
20101126_074231 AO78 9.9 65 11 NaN 0.05 092604 1 400 990 0.0 0.0 3 62 0.5 H 2000 15 ONSKY  
20101126_074311 AO78 10.0 65 11 NaN 0.05 092604 1 400 990 0.0 0.0 3 60 0.4 H 2000 15 ONSKY  
20101126_075053 AO78 9.3 64 11 NaN 1.07 092604 1 400 990 0.9 2.1 3 111 45.4 H 30 300 ONSKY  
20101126_075126 AO78 9.3 63 12 NaN 1.07 092604 1 400 990 0.9 2.1 3 110 40.1 H 30 300 ONSKY - long stop of 82 frames at frame 136
20101126_075157 AO78 9.3 63 12 NaN 1.03 092604 1 400 990 0.9 2.1 3 115 49.1 H 30 300 ONSKY  

LKHA330

075600 puntamento

<pre>

Primo giro OB, filtro H: funziona fino al primo offset lungo che da' errore perche' l'aos ritorna sempre un timeout. Di conseguenza non ci sono sky background



.[AOeng@wfsdx GUI]$ ./acq LKha330_H
Resmsg[0]  = SetIRParams command result: OK
Resmsg[1]  = New Integration time [microsec]: 100000
Resmsg[2]  = New Frame Rate [Hz]: 100000
----------------------------------------------
Set IRTC params: exptime=100000 microsec, framerate=100000 hz
Saved tracknum: 20101126_082043  (irtc=600 frames  ccd47=0 frames optical loop data=4000 frames)
Resmsg[0]  = SetIRParams command result: OK
Resmsg[1]  = New Integration time [microsec]: 1000000
Resmsg[2]  = New Frame Rate [Hz]: 100000
----------------------------------------------
Set IRTC params: exptime=1000000 microsec, framerate=100000 hz
Saved tracknum: 20101126_082221  (irtc=60 frames  ccd47=0 frames optical loop data=4000 frames)
Resmsg[0]  = OffsetXYAO result status: OK
Resmsg[1]  = [131]
----------------------------------------------
Executed offset : x=0.120 y=0.000 (mm)
Current position: x=0.200 y=0.000 (arcsec)
Saved tracknum: 20101126_082330  (irtc=60 frames  ccd47=0 frames optical loop data=4000 frames)
Resmsg[0]  = OffsetXYAO result status: OK
Resmsg[1]  = [132]
----------------------------------------------
Executed offset : x=-0.240 y=0.000 (mm)
Current position: x=-0.200 y=0.000 (arcsec)
Saved tracknum: 20101126_082438  (irtc=60 frames  ccd47=0 frames optical loop data=4000 frames)
Resmsg[0]  = OffsetXYAO result status: OK
Resmsg[1]  = [133]
----------------------------------------------
Executed offset : x=0.120 y=0.120 (mm)
Current position: x=0.000 y=0.200 (arcsec)
Saved tracknum: 20101126_082546  (irtc=60 frames  ccd47=0 frames optical loop data=4000 frames)
Resmsg[0]  = OffsetXYAO result status: OK
Resmsg[1]  = [134]
----------------------------------------------
Executed offset : x=0.000 y=-0.240 (mm)
Current position: x=0.000 y=-0.200 (arcsec)
Saved tracknum: 20101126_082654  (irtc=60 frames  ccd47=0 frames optical loop data=4000 frames)
Resmsg[0]  = OffsetXYAO result status: Error
Resmsg[1]  =  [135] - Command timeout - -13107: Arbitrator interface generic error----------------------------------------------

Exit 1
Error: pos command exited with status 256
Saved tracknum: 20101126_082811  (irtc=60 frames  ccd47=0 frames optical loop data=4000 frames)
----------------------------------------------
Resmsg[0]  = OffsetXYAO result status: Error
Resmsg[1]  =  [136] - Command timeout - -13107: Arbitrator interface generic error

Secondo giro OB, stavolta in J. C'e' ancora qualche problema con l'offset ma gli sky background sono stati presi tutti, probabilmente in posizioni un po' diverse da quelle attese ma sempre con la sorgente fuori campo. PERO'...... si scopre che la camera non era raffreddata! (T=270K)


[AOeng@wfsdx GUI]$ ./acq LKha330_H 
Resmsg[0]  = SetIRParams command result: OK
Resmsg[1]  = New Integration time [microsec]: 100000
Resmsg[2]  = New Frame Rate [Hz]: 100000
----------------------------------------------
Set IRTC params: exptime=100000 microsec, framerate=100000 hz
Saved tracknum: 20101126_085359  (irtc=600 frames  ccd47=0 frames optical loop data=4000 frames)
Resmsg[0]  = SetIRParams command result: OK
Resmsg[1]  = New Integration time [microsec]: 1000000
Resmsg[2]  = New Frame Rate [Hz]: 100000
----------------------------------------------
Set IRTC params: exptime=1000000 microsec, framerate=100000 hz
Saved tracknum: 20101126_085536  (irtc=60 frames  ccd47=0 frames optical loop data=4000 frames)
Resmsg[0]  = OffsetXYAO result status: OK
Resmsg[1]  = [156]
----------------------------------------------
Executed offset : x=0.120 y=0.000 (mm)
Current position: x=0.200 y=0.000 (arcsec)
Saved tracknum: 20101126_085644  (irtc=60 frames  ccd47=0 frames optical loop data=4000 frames)
Resmsg[0]  = OffsetXYAO result status: OK
Resmsg[1]  = [157]
----------------------------------------------
Executed offset : x=-0.240 y=0.000 (mm)
Current position: x=-0.200 y=0.000 (arcsec)
Saved tracknum: 20101126_085752  (irtc=60 frames  ccd47=0 frames optical loop data=4000 frames)
Resmsg[0]  = OffsetXYAO result status: OK
Resmsg[1]  = [158]
----------------------------------------------
Executed offset : x=0.120 y=0.120 (mm)
Current position: x=0.000 y=0.200 (arcsec)
Saved tracknum: 20101126_085902  (irtc=60 frames  ccd47=0 frames optical loop data=4000 frames)
Resmsg[0]  = OffsetXYAO result status: OK
Resmsg[1]  = [159]
----------------------------------------------
Executed offset : x=0.000 y=-0.240 (mm)
Current position: x=0.000 y=-0.200 (arcsec)
Saved tracknum: 20101126_090011  (irtc=60 frames  ccd47=0 frames optical loop data=4000 frames)
----------------------------------------------
Resmsg[0]  = OffsetXYAO result status: Error
Resmsg[1]  =  [160] - Command timeout - -13107: Arbitrator interface generic error
Exit 1
Executed offset : x=3.600 y=0.120 (mm)
Current position: x=6.000 y=0.000 (arcsec)
Saved tracknum: 20101126_090155  (irtc=60 frames  ccd47=0 frames optical loop data=4000 frames)
----------------------------------------------
Resmsg[0]  = OffsetXYAO result status: Error
Resmsg[1]  =  [161] - Command timeout - -13107: Arbitrator interface generic error
Exit 1
Error: pos command exited with status 256
Saved tracknum: 20101126_090311  (irtc=60 frames  ccd47=0 frames optical loop data=4000 frames)
----------------------------------------------
Resmsg[0]  = OffsetXYAO result status: Error
Resmsg[1]  =  [162] - Command timeout - -13107: Arbitrator interface generic error
Exit 1
Error: pos command exited with status 256
Saved tracknum: 20101126_090427  (irtc=60 frames  ccd47=0 frames optical loop data=4000 frames)
Resmsg[0]  = SetIRParams command result: OK
Resmsg[1]  = New Integration time [microsec]: 100000
Resmsg[2]  = New Frame Rate [Hz]: 100000
----------------------------------------------
Set IRTC params: exptime=100000 microsec, framerate=100000 hz
Saved tracknum: 20101126_090535  (irtc=600 frames  ccd47=0 frames optical loop data=4000 frames)
Resmsg[0]  = OffsetXYAO result status: Error
Resmsg[1]  = Illegal command for state Ready
Resmsg[2]  =  [163] - Illegal command for state Ready----------------------------------------------

Exit 1
Error: pos command exited with status 256
[AOeng@wfsdx GUI]$ 

Terzo giro OB, filltro J. Questa volta sembra andata bene! Camera T=240K


eng@wfsdx GUI]$ ./acq LKha330_H 
Resmsg[0]  = SetIRParams command result: OK
Resmsg[1]  = New Integration time [microsec]: 100000
Resmsg[2]  = New Frame Rate [Hz]: 100000
----------------------------------------------
Set IRTC params: exptime=100000 microsec, framerate=100000 hz
Saved tracknum: 20101126_091447  (irtc=600 frames  ccd47=0 frames optical loop data=4000 frames)
Resmsg[0]  = SetIRParams command result: OK
Resmsg[1]  = New Integration time [microsec]: 1000000
Resmsg[2]  = New Frame Rate [Hz]: 100000
----------------------------------------------
Set IRTC params: exptime=1000000 microsec, framerate=100000 hz
Saved tracknum: 20101126_091625  (irtc=60 frames  ccd47=0 frames optical loop data=4000 frames)
Resmsg[0]  = OffsetXYAO result status: OK
Resmsg[1]  = [168]
----------------------------------------------
Executed offset : x=0.120 y=0.000 (mm)
Current position: x=0.200 y=0.000 (arcsec)
Saved tracknum: 20101126_091734  (irtc=60 frames  ccd47=0 frames optical loop data=4000 frames)
Resmsg[0]  = OffsetXYAO result status: OK
Resmsg[1]  = [169]
----------------------------------------------
Executed offset : x=-0.240 y=0.000 (mm)
Current position: x=-0.200 y=0.000 (arcsec)
Saved tracknum: 20101126_091842  (irtc=60 frames  ccd47=0 frames optical loop data=4000 frames)
Resmsg[0]  = OffsetXYAO result status: OK
Resmsg[1]  = [170]
----------------------------------------------
Executed offset : x=0.120 y=0.120 (mm)
Current position: x=0.000 y=0.200 (arcsec)
Saved tracknum: 20101126_091950  (irtc=60 frames  ccd47=0 frames optical loop data=4000 frames)
Resmsg[0]  = OffsetXYAO result status: OK
Resmsg[1]  = [171]
----------------------------------------------
Executed offset : x=0.000 y=-0.240 (mm)
Current position: x=0.000 y=-0.200 (arcsec)
Saved tracknum: 20101126_092058  (irtc=60 frames  ccd47=0 frames optical loop data=4000 frames)
----------------------------------------------
Resmsg[0]  = OffsetXYAO result status: Error
Resmsg[1]  =  [172] - Command timeout - -13107: Arbitrator interface generic error
Exit 1
Executed offset : x=3.600 y=0.120 (mm)
Current position: x=6.000 y=0.000 (arcsec)
Saved tracknum: 20101126_092306  (irtc=60 frames  ccd47=0 frames optical loop data=4000 frames)
Resmsg[0]  = OffsetXYAO result status: OK
Resmsg[1]  = [173]
----------------------------------------------
Executed offset : x=0.300 y=0.000 (mm)
Current position: x=6.500 y=0.000 (arcsec)
Saved tracknum: 20101126_092415  (irtc=60 frames  ccd47=0 frames optical loop data=4000 frames)
Resmsg[0]  = OffsetXYAO result status: OK
Resmsg[1]  = [174]
----------------------------------------------
Executed offset : x=-0.600 y=0.000 (mm)
Current position: x=5.500 y=0.000 (arcsec)
Saved tracknum: 20101126_092527  (irtc=60 frames  ccd47=0 frames optical loop data=4000 frames)
Resmsg[0]  = SetIRParams command result: OK
Resmsg[1]  = New Integration time [microsec]: 100000
Resmsg[2]  = New Frame Rate [Hz]: 100000
----------------------------------------------
Set IRTC params: exptime=100000 microsec, framerate=100000 hz
Saved tracknum: 20101126_092633  (irtc=600 frames  ccd47=0 frames optical loop data=4000 frames)
----------------------------------------------
Resmsg[0]  = OffsetXYAO result status: Error
Resmsg[1]  =  [175] - Command timeout - -13107: Arbitrator interface generic error
Exit 1
Error: pos command exited with status 256
[AOeng@wfsdx GUI]$ 

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph SR band exp #frames disturb notes
20101126_082021 LKHA330 11.8 70 10 NaN 1.32 180534 2 150 991 0.9 2.5 3 48 -1.0 ? -1 -1 ONSKY  
20101126_082043 LKHA330 12.0 70 11 NaN 1.64 180534 2 150 991 0.9 2.5 3 39 5.4 H 100 600 ONSKY  
20101126_082221 LKHA330 11.7 70 11 NaN 1.14 180534 2 150 991 0.9 2.5 3 52 5.5 H 1000 60 ONSKY  
20101126_082330 LKHA330 11.7 69 11 NaN 1.20 180534 2 150 991 0.9 2.5 3 51 5.7 H 1000 60 ONSKY  
20101126_082438 LKHA330 11.7 69 11 NaN 1.03 180534 2 150 991 0.9 2.5 3 53 5.7 H 1000 60 ONSKY  
20101126_082546 LKHA330 11.6 69 12 NaN 0.93 180534 2 150 991 0.9 2.5 3 57 6.6 H 1000 60 ONSKY  
20101126_082654 LKHA330 11.7 69 11 NaN 0.96 180534 2 150 991 0.9 2.5 3 55 6.2 H 1000 60 ONSKY  
20101126_082811 LKHA330 11.6 68 12 NaN 0.77 180534 2 150 991 0.9 2.5 3 56 6.0 H 1000 60 ONSKY  
20101126_082929 LKHA330 11.7 68 11 NaN 0.79 180534 2 150 991 0.9 2.4 3 55 -1.0 ? -1 -1 ONSKY  
20101126_085257 LKHA330 11.4 63 9 NaN 0.73 180534 2 150 991 0.8 1.9 3 70 -1.0 ? -1 -1 ONSKY  
20101126_085310 LKHA330 11.4 63 11 NaN 0.74 180534 2 150 991 0.8 1.9 3 69 43.3 J 1000 29 ONSKY  
20101126_085343 LKHA330 11.4 63 9 NaN 0.85 180534 2 150 991 0.8 1.9 3 67 43.6 J 1000 7 ONSKY  
20101126_085359 LKHA330 11.4 63 10 NaN 0.79 180534 2 150 991 0.8 1.9 3 68 ** J 100 600 ONSKY  
20101126_085536 LKHA330 11.5 63 9 NaN 0.90 180534 2 150 991 0.8 1.9 3 65 44.1 J 1000 60 ONSKY  
20101126_085644 LKHA330 11.5 62 11 NaN 0.85 180534 2 150 991 0.8 1.9 3 63 ** J 1000 60 ONSKY  
20101126_085752 LKHA330 11.5 62 11 NaN 0.82 180534 2 150 991 0.8 1.9 3 62 31.6 J 1000 60 ONSKY  
20101126_085902 LKHA330 11.5 62 10 NaN 0.99 180534 2 150 991 0.8 1.9 3 61 24.9 J 1000 60 ONSKY  
20101126_090011 LKHA330 11.6 62 11 NaN 0.89 180534 2 150 991 0.8 1.9 3 60 54.1 J 1000 60 ONSKY  
20101126_090155 LKHA330 11.5 61 10 NaN 0.75 180534 2 150 991 0.8 1.9 3 62 ** J 1000 60 ONSKY  
20101126_090311 LKHA330 11.6 61 8 NaN 1.09 180534 2 150 991 0.8 1.9 3 56 0.0 J 1000 60 ONSKY  
20101126_090427 LKHA330 11.7 61 10 NaN 1.14 180534 2 150 991 0.8 1.9 3 55 231.7 J 1000 60 ONSKY  
20101126_090535 LKHA330 11.6 61 10 NaN 1.04 180534 2 150 991 0.8 1.9 3 56 ** J 100 600 ONSKY  
20101126_091447 LKHA330 11.4 59 11 NaN 0.83 180534 2 150 991 0.8 2.0 3 71 3.3 J 100 600 ONSKY  
20101126_091625 LKHA330 11.4 58 11 NaN 0.88 180534 2 150 991 0.8 2.0 3 70 5.6 J 1000 60 ONSKY  
20101126_091734 LKHA330 11.4 58 10 NaN 0.95 180534 2 150 991 0.8 2.0 3 68 5.5 J 1000 60 ONSKY  
20101126_091842 LKHA330 11.5 58 11 NaN 1.22 180534 2 150 991 0.8 2.0 3 63 2.5 J 1000 60 ONSKY  
20101126_091950 LKHA330 11.4 58 11 NaN 0.89 180534 2 150 991 0.8 2.0 3 69 3.7 J 1000 60 ONSKY  
20101126_092058 LKHA330 11.4 57 11 NaN 0.85 180534 2 150 991 0.8 2.0 3 68 3.3 J 1000 60 ONSKY  
20101126_092306 LKHA330 11.4 57 11 NaN 0.76 180534 2 150 991 0.8 2.0 3 70 23.9 J 1000 60 ONSKY  
20101126_092415 LKHA330 11.4 57 9 NaN 1.02 180534 2 150 991 0.8 2.0 3 67 20.7 J 1000 60 ONSKY  
20101126_092527 LKHA330 11.6 56 8 NaN 1.31 180534 2 150 991 0.8 2.0 3 60 23.2 J 1000 60 ONSKY  
20101126_092633 LKHA330 11.5 56 11 NaN 1.11 180534 2 150 991 0.8 2.0 3 64 0.0 J 100 600 ONSKY  
20101126_093128 LKHA330 11.4 55 11 NaN 0.86 180534 2 150 991 0.8 2.0 3 67 32.9 H 100 100 ONSKY  
20101126_093156 LKHA330 11.5 55 9 NaN 1.10 180534 2 150 991 0.8 2.0 3 63 20.3 H 100 100 ONSKY  
20101126_093218 LKHA330 11.5 55 9 NaN 0.94 180534 2 150 991 0.8 2.0 3 66 28.0 H 100 100 ONSKY  
20101126_094002 LKHA330 11.4 53 11 NaN 0.94 180534 2 150 991 1.3 2.4 3 67 30.1 H 100 100 ONSKY  
20101126_094023 LKHA330 11.5 53 11 NaN 1.26 180534 2 150 991 1.3 2.4 3 63 18.4 H 100 100 ONSKY  
20101126_094042 LKHA330 11.6 53 11 NaN 1.32 180534 2 150 991 1.3 2.4 3 60 14.0 H 100 100 ONSKY  
20101126_094428 LKHA330 11.6 53 10 NaN 1.39 180534 2 150 991 1.3 2.4 3 59 12.7 H 100 100 ONSKY  
20101126_094446 LKHA330 11.5 52 11 NaN 1.26 180534 2 150 991 1.3 2.4 3 61 19.6 H 100 100 ONSKY  
20101126_094504 LKHA330 11.5 52 11 NaN 1.00 180534 2 150 991 1.3 2.4 3 66 26.4 H 100 100 ONSKY  
20101126_094805 LKHA330 11.6 52 11 NaN 1.44 180534 2 150 991 1.3 2.4 3 58 10.6 H 100 100 ONSKY  
20101126_094823 LKHA330 11.5 52 11 NaN 1.20 180534 2 150 991 1.3 2.4 3 62 15.3 H 100 100 ONSKY  
20101126_094841 LKHA330 11.6 52 11 NaN 1.44 180534 2 150 991 1.3 2.4 3 56 8.2 H 100 100 ONSKY  

Installazione densita'

AO247

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph SR band exp #frames disturb notes
20101126_104557 AO247 12.6 72 10 NaN 1.25 180534 2 150 474 1.5 3.0 3 47 6.1 H 500 20 ONSKY Errore fuoco
20101126_104630 AO247 12.7 72 9 NaN 1.44 180534 2 150 474 1.5 3.0 3 45 3.8 H 500 20 ONSKY Errore fuoco
20101126_104654 AO247 12.6 72 10 NaN 1.37 180534 2 150 474 1.5 3.0 3 47 2.8 H 500 20 ONSKY Errore fuoco
20101126_105624 AO247 13.5 70 10 NaN 0.08 075552 3 66 364 0.0 0.0 6 64 0.2 H 2000 15 ONSKY Errore fuoco OL
20101126_105710 AO247 13.7 70 10 NaN 0.08 075552 3 66 364 0.0 0.0 6 52 0.4 H 2000 15 ONSKY Errore fuoco OL
20101126_105750 AO247 13.8 70 10 NaN 0.08 075552 3 66 364 0.0 0.0 6 49 0.3 H 2000 15 ONSKY Errore fuoco OL

110200 il solito errore di fuoco. tutte le misure fino ad ora sono sbagliate

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph SR band exp #frames disturb notes
20101126_110353 AO247 12.9 68 9 NaN 1.34 075552 3 66 364 2.2 2.5 6 106 3.7 H 200 50 ONSKY - long stop of 60 frames at frame 748
20101126_110438 AO247 12.8 68 10 NaN 1.19 075552 3 66 364 2.2 2.5 6 117 8.2 H 200 50 ONSKY - long stop of 66 frames at frame 2376
20101126_110456 AO247 12.9 68 10 NaN 1.25 075552 3 66 364 2.2 2.5 6 110 3.7 H 200 50 ONSKY - long stop of 80 frames at frame 1840
20101126_110724 AO247 12.7 68 9 NaN 0.92 075552 3 66 364 2.2 2.2 6 125 -1.0 ? -1 -1 ONSKY  
20101126_110743 AO247 12.8 68 9 NaN 1.14 075552 3 66 364 2.2 2.2 6 119 9.0 H 50 200 ONSKY  
20101126_110810 AO247 12.8 67 9 NaN 1.20 075552 3 66 364 2.2 2.2 6 114 5.9 H 50 200 ONSKY  
20101126_110844 AO247 12.9 67 9 NaN 1.26 075552 3 66 364 2.2 2.2 6 109 3.6 H 50 200 ONSKY  

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph SR band exp #frames disturb notes
20101126_120626 AO247 12.4 55 9 NaN 0.85 180534 2 150 495 1.2 3.1 3 54 19.1 H 50 200 ONSKY  
20101126_120703 AO247 12.4 55 9 NaN 0.92 180534 2 150 495 1.2 3.1 3 54 16.2 H 50 200 ONSKY  
20101126_120743 AO247 12.4 55 9 NaN 0.83 180534 2 150 495 1.2 3.1 3 53 20.3 H 50 200 ONSKY  
20101126_121231 AO247 12.4 54 9 NaN 0.95 180534 2 150 495 1.4 3.1 3 55 12.7 H 50 200 ONSKY  
20101126_121258 AO247 12.4 54 9 NaN 0.81 180534 2 150 495 1.4 3.1 3 58 23.5 H 50 200 ONSKY - long stop of 11 frames at frame 2524
20101126_121324 AO247 12.4 54 10 NaN 0.76 180534 2 150 495 1.4 3.1 3 55 29.4 H 50 200 ONSKY  
20101126_121429 AO247 12.5 54 9 NaN 0.05 180534 2 150 495 0.0 0.0 3 53 -1.0 ? -1 -1 ONSKY  
20101126_121452 AO247 12.5 54 9 NaN 0.05 180534 2 150 495 0.0 0.0 3 52 0.4 H 500 60 ONSKY  
20101126_121532 AO247 12.5 53 9 NaN 0.05 180534 2 150 495 0.0 0.0 3 49 0.6 H 500 60 ONSKY  
20101126_121610 AO247 12.8 53 9 NaN 0.04 180534 2 150 495 0.0 0.0 3 40 0.5 H 500 60 ONSKY  
20101126_121701 AO247 13.1 53 9 NaN 0.06 180534 2 150 495 0.0 0.0 3 28 1.3 H 500 60 ONSKY  
20101126_122311 AO247 12.3 52 9 NaN 0.05 180534 2 150 495 0.0 0.0 3 59 0.6 H 500 60 ONSKY  
20101126_122350 AO247 12.3 52 9 NaN 0.05 180534 2 150 495 0.0 0.0 3 58 0.6 H 500 60 ONSKY  

AO327

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph SR band exp #frames disturb notes
20101126_132424 AO327 13.4 60 8 NaN 0.96 075552 3 66 297 2.3 2.4 6 83 8.9 H 200 50 ONSKY  
20101126_132442 AO327 13.4 60 8 NaN 1.00 075552 3 66 297 2.3 2.4 6 81 6.1 H 200 50 ONSKY  
20101126_132459 AO327 13.5 60 7 NaN 1.20 075552 3 66 297 2.3 2.4 6 78 4.4 H 200 50 ONSKY  
20101126_132550 AO327 13.6 60 8 NaN 0.09 075552 3 66 297 0.0 0.0 6 70 0.3 H 2000 15 ONSKY  
20101126_132626 AO327 13.7 60 9 NaN 0.09 075552 3 66 297 0.0 0.0 6 63 0.4 H 2000 15 ONSKY  
20101126_132729 AO327 13.6 60 9 NaN 1.60 075552 3 66 297 2.3 2.5 6 69 1.4 H 200 15 ONSKY  
20101126_132747 AO327 13.7 60 8 NaN 1.64 075552 3 66 297 2.3 2.5 6 64 0.7 H 200 15 ONSKY  