Test SW tabella automatica

TrackNo RefStar Mag El Wind DIMM Rec bin #mod freq gain mod nph SR band exp #frames disturb notes
20101120_184651 ??? 12.1 90 14 NaN 071604 2 153 804 0.1 0.6 3 45 73.1 H 200 50 OFF  
20101120_184716 ??? 12.1 90 17 NaN 071604 2 153 804 0.1 0.6 3 45 74.3 H 200 50 OFF  
20101120_184740 ??? 12.1 90 17 NaN 071604 2 153 804 0.1 0.6 3 45 74.2 H 200 50 OFF  
20101120_185011 ??? 12.1 90 15 NaN 071604 2 153 804 0.3 0.6 3 45 71.3 H 200 50 OFF  
20101120_185035 ??? 12.1 90 17 NaN 071604 2 153 804 0.3 0.6 3 45 70.3 H 200 50 OFF  
20101120_185054 ??? 12.1 90 18 NaN 071604 2 153 804 0.3 0.6 3 44 69.6 H 200 50 OFF  
20101120_185116 ??? 12.1 90 17 NaN 071604 2 153 804 0.5 0.6 3 44 64.3 H 200 50 OFF  
20101120_185133 ??? 12.1 90 17 NaN 071604 2 153 804 0.5 0.6 3 43 65.2 H 200 50 OFF  
20101120_185748 ??? 12.1 90 20 NaN 071604 2 153 804 0.4 1.0 3 44 44.1 H 200 50 ON  
20101120_185807 ??? 12.1 90 18 NaN 071604 2 153 804 0.4 1.0 3 44 41.1 H 200 50 ON  
20101120_185826 ??? 12.1 90 18 NaN 071604 2 153 804 0.4 1.0 3 45 37.7 H 200 50 ON  
20101120_190445 ??? 12.1 90 17 NaN 071604 2 153 804 0.4 1.0 3 44 42.7 H 200 50 ON  
20101120_190523 ??? 12.1 90 17 NaN 071604 2 153 804 0.4 1.0 3 44 40.6 H 200 50 ON  
20101120_190541 ??? 12.1 90 16 NaN 071604 2 153 804 0.4 1.0 3 44 44.0 H 200 50 ON  
20101120_190900 ??? 12.1 90 8 NaN 180534 2 150 804 0.4 1.0 3 45 45.8 H 200 50 ON  
20101120_190918 ??? 12.1 90 10 NaN 180534 2 150 804 0.4 1.0 3 44 45.1 H 200 50 ON  
20101120_190937 ??? 12.1 90 10 NaN 180534 2 150 804 0.4 1.0 3 44 47.5 H 200 50 ON  
20101120_191252 ??? 12.1 90 13 NaN 180534 2 150 804 0.3 1.0 3 43 46.5 H 200 50 ON  

SW per aggiustamento automatico del clock della pup

test ok

Mettiamo la densita'

Sembra che atttenui solamente un fattore 30, ovvero 3.7 mag. Avevamo 1550 phot/sub a bin 1 @1kHz e 200 a bin2 @1kHz con la lampada allo stesso livello.

Cerchiamo di vedere le performance a mag 12 ma le vibrazioni sembrano dominare le performances

TrackNo RefStar Mag El Wind DIMM Rec bin #mod freq gain mod nph SR band exp #frames disturb notes
20101120_201921 ??? 7.4 90 16 NaN 092604 1 400 990 0.4 0.5 3 640 75.2 H 30 300 ON  
20101120_201951 ??? 7.4 90 13 NaN 092604 1 400 990 0.4 0.5 3 639 72.5 H 30 300 ON  
20101120_202020 ??? 7.4 90 17 NaN 092604 1 400 990 0.4 0.5 3 639 75.0 H 30 300 ON  
20101120_202050 ??? 7.4 90 15 NaN 092604 1 400 990 0.4 0.5 3 639 72.3 H 30 300 ON  
20101120_202238 ??? 7.4 90 17 NaN 092604 1 400 990 0.4 0.5 3 647 71.0 H 30 300 ON  
20101120_202309 ??? 7.4 90 18 NaN 092604 1 400 990 0.4 0.5 3 647 76.1 H 30 300 ON  
20101120_202338 ??? 7.4 90 14 NaN 092604 1 400 990 0.4 0.5 3 647 73.7 H 30 300 ON - long stop of 17 frames at frame 755
20101120_202521 ??? 7.4 90 14 NaN 092604 1 400 990 0.4 0.4 3 647 67.8 H 30 300 ON  
20101120_202551 ??? 7.4 90 14 NaN 092604 1 400 990 0.4 0.4 3 647 70.7 H 30 300 ON  
20101120_203554 ??? 7.4 90 14 NaN 092604 1 400 990 0.4 0.6 3 645 75.3 H 30 300 ON  
20101120_203625 ??? 7.4 90 13 NaN 092604 1 400 990 0.4 0.6 3 644 72.2 H 30 300 ON  
20101120_203655 ??? 7.4 90 16 NaN 092604 1 400 990 0.4 0.6 3 642 74.1 H 30 300 ON  
20101120_203816 ??? 7.4 90 17 NaN 092604 1 400 990 0.4 0.6 3 644 73.1 H 30 300 ON  
20101120_203845 ??? 7.4 90 18 NaN 092604 1 400 990 0.4 0.6 3 645 72.1 H 30 300 ON  
20101120_203917 ??? 7.4 90 16 NaN 092604 1 400 990 0.4 0.6 3 645 73.2 H 30 300 ON  
20101120_222950 ??? 12.6 90 18 NaN 180534 2 150 608 0.4 1.4 3 38 -1.0 ? -1 -1 ON  
20101120_223008 ??? 12.6 90 17 NaN 180534 2 150 608 0.4 1.4 3 38 30.5 H 50 200 ON  
20101120_223033 ??? 12.6 90 14 NaN 180534 2 150 608 0.4 1.4 3 38 32.9 H 50 200 ON  
20101120_223058 ??? 12.6 90 17 NaN 180534 2 150 608 0.4 1.4 3 37 31.8 H 50 200 ON  
20101120_223523 ??? 12.6 90 16 NaN 180534 2 150 608 0.4 0.8 3 37 -1.0 ? -1 -1 ON  
20101120_223542 ??? 12.6 90 11 NaN 180534 2 150 608 0.4 0.8 3 37 28.6 H 50 200 ON  
20101120_223610 ??? 12.6 90 16 NaN 180534 2 150 608 0.4 0.8 3 37 28.2 H 50 200 ON  
20101120_223637 ??? 12.6 90 16 NaN 180534 2 150 608 0.4 0.8 3 37 28.1 H 50 200 ON  
20101120_224545 ??? 12.6 90 23 NaN 180534 2 150 801 0.3 1.0 3 29 31.9 H 50 200 ON  
20101120_224616 ??? 12.6 90 19 NaN 180534 2 150 801 0.3 1.0 3 29 31.2 H 50 200 ON  
20101120_224641 ??? 12.6 90 19 NaN 180534 2 150 801 0.3 1.0 3 29 32.0 H 50 200 ON  
20101120_225331 ??? 12.1 90 12 NaN 180534 2 150 991 0.3 0.9 3 37 36.9 H 50 200 ON  
20101120_225400 ??? 12.1 90 15 NaN 180534 2 150 991 0.3 0.9 3 37 37.6 H 50 200 ON  
20101120_225425 ??? 12.1 90 8 NaN 180534 2 150 991 0.3 0.9 3 37 38.8 H 50 200 ON  
20101120_225452 ??? 12.1 90 16 NaN 180534 2 150 991 0.3 0.9 3 37 37.8 H 50 200 ON  
20101120_230714 ??? 12.0 90 13 NaN 180534 2 150 991 0.2 0.4 3 40 60.5 H 50 200 OFF  
20101120_230739 ??? 12.0 90 13 NaN 180534 2 150 991 0.2 0.4 3 40 59.5 H 50 200 OFF  
20101120_230806 ??? 12.0 90 13 NaN 180534 2 150 991 0.2 0.4 3 41 56.6 H 50 200 OFF  
20101120_231013 ??? 11.9 90 18 NaN 180534 2 150 991 0.2 0.4 3 43 58.5 H 10 1000 OFF  
20101120_231605 ??? 12.1 90 14 NaN 180534 2 150 991 0.2 0.8 3 36 56.4 H 50 1000 OFF  
20101120_232015 ??? 12.3 90 16 NaN 180534 2 150 991 0.2 0.3 3 29 57.6 H 50 200 OFF  
20101120_232043 ??? 12.4 90 13 NaN 180534 2 150 991 0.2 0.3 3 29 57.5 H 50 200 OFF  
20101120_232108 ??? 12.3 90 17 NaN 180534 2 150 991 0.2 0.3 3 29 57.4 H 50 200 OFF  
20101120_232230 ??? 12.3 90 13 NaN 180534 2 150 991 0.2 0.3 3 29 -1.0 ? -1 -1 OFF  
20101120_232248 ??? 12.3 90 12 NaN 180534 2 150 991 0.2 0.3 3 29 56.6 H 50 200 OFF  
20101120_232315 ??? 12.3 90 13 NaN 180534 2 150 991 0.2 0.3 3 29 56.1 H 50 200 OFF - long stop of 17 frames at frame 1774
20101120_232347 ??? 12.3 90 17 NaN 180534 2 150 991 0.2 0.3 3 29 56.6 H 50 200 OFF  
20101120_233713 ??? 13.4 90 16 NaN 180534 2 150 487 0.3 1.0 3 23 46.0 H 50 200 OFF  
20101120_233744 ??? 13.4 90 13 NaN 180534 2 150 487 0.3 1.0 3 23 44.5 H 50 200 OFF  
20101120_233810 ??? 13.4 90 15 NaN 180534 2 150 487 0.3 1.0 3 23 45.5 H 50 200 OFF  
20101121_191101 ??? 10.5 90 16 NaN 180534 2 150 991 0.3 0.5 3 163 -1.0 ? -1 -1 ON  
20101121_191234 ??? 10.1 90 15 NaN 180534 2 150 991 0.3 0.5 3 236 38.6 H 30 300 ON  

Topic revision: r4 - 11 Sep 2012, EnricoPinna
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding Foswiki? Send feedback