Stella AO_04P000M08_2 R=6.8, H=4.7

C'e' un seeing molto alto >2", si tiene con difficolta' la stella

REC Base IM bin mod #modes TTrem cutted notes
20101026_094431 KL_v6 20101021_082657 1 3 400 ON 0  

TrackNo RefStar Mag El Wind DIMM Rec bin #mod freq gain mod nph SR band exp #frames disturb notes
20101026_103141 AO_04P000M08_2 7.4 69 10 1.86 214405 1 399 1000 0.8 0.9 3 616 -1.0 ? -1 -1 ONSKY  
20101026_103158 AO_04P000M08_2 7.4 69 14 1.67 214405 1 399 1000 0.8 0.9 3 619 25.4 H 5 500 ONSKY  
20101026_103241 AO_04P000M08_2 7.4 69 12 1.61 214405 1 399 1000 0.8 0.9 3 642 50.4 H 5 500 ONSKY  
20101026_103322 AO_04P000M08_2 7.4 69 14 1.57 214405 1 399 1000 0.8 0.9 3 617 23.7 H 5 500 ONSKY  
20101026_103821 AO_04P000M08_2 7.5 68 12 1.86 214405 1 399 1000 0.8 0.9 3 579 26.9 H 5 500 ONSKY  
20101026_103906 AO_04P000M08_2 7.4 68 9 1.63 214405 1 399 1000 0.8 0.9 3 642 48.1 H 5 500 ONSKY  
20101026_103957 AO_04P000M08_2 7.5 68 11 1.55 214405 1 399 1000 0.8 0.9 3 588 22.6 H 5 500 ONSKY  
20101026_110320 AO_04P000M08_2 7.5 63 12 1.50 092604 1 400 1000 0.5 0.7 3 610 -1.0 ? -1 -1 ONSKY  
20101026_110334 AO_04P000M08_2 7.4 63 13 1.57 092604 1 400 1000 0.5 0.7 3 637 -1.0 ? -1 -1 ONSKY  
20101026_110351 AO_04P000M08_2 7.4 63 13 1.62 092604 1 400 1000 0.5 0.7 3 630 -1.0 ? -1 -1 ONSKY  
20101026_110409 AO_04P000M08_2 7.4 63 11 1.30 092604 1 400 1000 0.5 0.7 3 636 27.2 H 5 500 ONSKY  
20101026_110500 AO_04P000M08_2 7.4 63 9 1.44 092604 1 400 1000 0.5 0.7 3 637 19.1 H 5 500 ONSKY  
20101026_110544 AO_04P000M08_2 7.4 63 6 1.49 092604 1 400 1000 0.5 0.7 3 629 13.4 H 5 500 ONSKY  
20101026_110919 AO_04P000M08_2 7.4 62 11 1.45 092604 1 400 1000 0.5 0.7 3 623 -1.0 ? -1 -1 ONSKY  
20101026_110944 AO_04P000M08_2 7.5 62 11 1.52 092604 1 400 1000 0.5 0.7 3 589 6.4 H 5 500 ONSKY  
20101026_111030 AO_04P000M08_2 7.4 62 4 1.58 092604 1 400 1000 0.5 0.7 3 622 15.2 H 5 500 ONSKY  
20101026_111116 AO_04P000M08_2 7.4 62 9 1.34 092604 1 400 1000 0.5 0.7 3 643 24.4 H 5 500 ONSKY  
20101026_111309 AO_04P000M08_2 7.4 61 6 1.28 092604 1 400 1000 0.8 0.9 3 653 44.9 H 5 500 ONSKY  
20101026_111351 AO_04P000M08_2 7.5 61 8 1.30 092604 1 400 1000 0.8 0.9 3 613 28.8 H 5 500 ONSKY  
20101026_111432 AO_04P000M08_2 7.5 61 7 1.49 092604 1 400 1000 0.8 0.9 3 599 31.4 H 5 500 ONSKY  
20101026_111618 AO_04P000M08_2 7.4 61 9 1.41 092604 1 400 1000 0.8 0.9 3 617 32.0 H 5 500 ONSKY  
20101026_111702 AO_04P000M08_2 7.4 61 9 1.42 092604 1 400 1000 0.8 0.9 3 629 34.4 H 5 500 ONSKY  
20101026_112610 AO_04P000M08_2 7.4 59 6 1.29 092604 1 400 1000 0.8 0.9 3 653 47.1 H 5 500 ONSKY  
20101026_112722 AO_04P000M08_2 7.4 59 6 1.25 092604 1 400 1000 0.8 0.9 3 645 49.4 H 5 500 ONSKY  
20101026_112925 AO_04P000M08_2 7.4 58 5 1.43 092604 1 400 1000 0.8 0.9 3 640 35.8 H 5 500 ONSKY  

Dice five

Visto che il seeing continua a fare schifo ci mettiamo a fare il dice five. Testiamo la ripetibilità dell'offset delle slitte facendo avanti e indietro su una serie punti posizionati a croce, con una distanza dal centro di circa 1 arcsec (l'offset viene diviso in due parti dall'AOArb perché supera l'offset singolo che è possibile fare).

From: 20101026_114141 To: 20101026_121549

Test ripetibilità misura centroide (senza muovere): 121549, 121614, 121639

La ripetibilità della misura viene fuori circa 4 mas La ripetibilità degli offset viene uguale o minore a quella della misura, tranne il movimento X negativo che su 3 punti ha un picco valle di 23 mas.