Bin1 per riscaldamento

TrackNo RefStar Mag El Wind Rec bin #mod freq gain mod nph SR band exp #frames disturb notes
20101015_165405 rr 6.5 90 0 214405 1 399 1000 0.3 0.3 3 1516 74.9 H 15 1000 OFF  
20101015_170003 rr 6.4 90 0 214405 1 399 1000 0.3 0.3 3 1693 70.0 H 15 1000 OFF  
20101015_170143 rr 6.4 90 0 214405 1 399 1000 0.3 0.3 3 1608 75.6 H 15 1000 OFF  

OK

Bin3

TrackNo RefStar Mag El Wind Rec bin #mod freq gain mod nph SR band exp #frames disturb notes
20101015_172015 rr 8.4 90 0 212832 3 65 900 0.2 0.3 5 2628 66.0 H 40 200 OFF  
20101015_172046 rr 8.5 90 0 212832 3 65 900 0.2 0.3 5 2625 64.3 H 40 200 OFF  
20101015_172137 rr 8.5 90 0 212832 3 65 900 0.2 0.3 5 2621 66.0 H 40 200 OFF  

Con disturbo

TrackNo RefStar Mag El Wind Rec bin #mod freq gain mod nph SR band exp #frames disturb notes
20101015_173208 rr 7.9 90 0 212832 3 65 900 0.4 0.7 5 4340 25.8 H 40 200 ON  
20101015_173249 rr 7.9 90 0 212832 3 65 900 0.4 0.7 5 4339 25.5 H 40 200 ON  
20101015_173323 rr 7.9 90 0 212832 3 65 900 0.4 0.7 5 4337 24.7 H 40 200 ON  
20101015_173348 rr 7.9 90 0 212832 3 65 900 0.4 0.7 5 4336 25.6 H 40 200 ON  
20101015_173421 rr 7.9 90 0 212832 3 65 900 0.4 0.7 5 4332 25.2 H 40 200 ON  
20101015_173448 rr 7.9 90 0 212832 3 65 900 0.4 0.7 5 4331 24.8 H 40 200 ON  
20101015_173553 rr 7.9 90 0 212832 3 65 900 0.0 0.0 5 4426 3.7 H 40 200 ON Open loop per TF
20101015_173619 rr 7.9 90 0 212832 3 65 900 0.0 0.0 5 4423 3.8 H 40 200 ON  
20101015_173643 rr 7.9 90 0 212832 3 65 900 0.0 0.0 5 4424 4.9 H 40 200 ON  

Sembra tutto ok. Il 28/09 erano fatti a 700 Hz, si riprova per confronto

TrackNo RefStar Mag El Wind Rec bin #mod freq gain mod nph SR band exp #frames disturb notes
20101015_174955 rr 7.6 90 0 212832 3 65 699 0.6 0.9 6 7717 34.2 H 40 200 ON Disturbo sbagliato 1000Hz
20101015_175020 rr 7.6 90 0 212832 3 65 699 0.6 0.9 6 7722 33.9 H 40 200 ON Disturbo sbagliato 1000Hz
20101015_175045 rr 7.6 90 0 212832 3 65 699 0.6 0.9 6 7720 33.1 H 40 200 ON Disturbo sbagliato 1000Hz

Pure meglio che a 900Hz e meglio che il 28/09. Nota del 22 oct: c'era il disturbo sbagliato, che andava a solo 10 m/s.

Bin4

TrackNo RefStar Mag El Wind Rec bin #mod freq gain mod nph SR band exp #frames disturb notes
20101015_180237 rr 9.5 90 0 224817 4 36 701 0.4 0.6 6 2597 74.8 H 40 200 OFF  
20101015_180310 rr 9.5 90 0 224817 4 36 701 0.4 0.6 6 2592 72.7 H 40 200 OFF  
20101015_180335 rr 9.5 90 0 224817 4 36 701 0.4 0.6 6 2592 69.7 H 40 200 OFF  

Con disturbo a 700 Hz

TrackNo RefStar Mag El Wind Rec bin #mod freq gain mod nph SR band exp #frames disturb notes
20101015_181239 rr 9.3 90 0 224817 4 36 701 0.6 1.1 6 3173 17.9 H 80 200 ON  
20101015_181328 rr 9.3 90 0 224817 4 36 701 0.6 1.1 6 3172 17.9 H 80 200 ON  
20101015_181405 rr 9.3 90 0 224817 4 36 701 0.6 1.1 6 3168 16.5 H 80 200 ON  
20101015_181448 rr 9.3 90 0 224817 4 36 701 0.6 1.1 6 3162 16.5 H 80 200 ON  

Proviamo piu' lentamente per vedere il prodotto banda-gaudagno vs SR

TrackNo RefStar Mag El Wind Rec bin #mod freq gain mod nph SR band exp #frames disturb notes
20101015_182657 rr 9.1 90 0 224817 4 36 501 0.8 1.6 6 5021 19.8 H 80 200 ON  
20101015_182744 rr 9.1 90 0 224817 4 36 501 0.8 1.6 6 5012 19.4 H 80 200 ON  
20101015_182817 rr 9.1 90 0 224817 4 36 501 0.8 1.6 6 5007 19.2 H 80 200 ON  
20101015_182850 rr 9.1 90 0 224817 4 36 501 0.8 1.6 6 5002 19.6 H 80 200 ON  
20101015_183238 rr 9.1 90 0 224817 4 36 501 0.0 0.0 6 5112 3.8 H 80 200 ON  
20101015_183314 rr 9.1 90 0 224817 4 36 501 0.0 0.0 6 5108 4.4 H 80 200 ON  
20101015_183351 rr 9.1 90 0 224817 4 36 501 0.0 0.0 6 5088 4.1 H 80 200 ON  

500Hz * [1.6, 0.8] = [900, 450] => SR = 19.5

700Hz * [1.1, 0.6] = [770, 420] => SR = 17.5

Ricostruttore a 500 modi a bin1 KL_v6

Intmat 550 modi: 20101015_192237

Poi ci sono 2 Recs che non hanno funzionato (20101015_202814 e 20101015_195912).

Il terzo 20101015_203420 e' fatto con skip 2 e average 2 (???? bug ????) con tilt removed. Questo funziona bene.

TrackNo RefStar Mag El Wind Rec bin #mod freq gain mod nph SR band exp #frames disturb notes
20101015_204330 rr 6.5 90 0 203420 1 500 600 0.5 0.9 3 2555 72.9 H 15 1000 OFF  
20101015_204528 rr 6.5 90 0 203420 1 500 600 0.5 0.9 3 2533 72.7 H 15 1000 OFF  
20101015_204700 rr 6.5 90 0 203420 1 500 600 0.5 0.9 3 2542 72.3 H 15 1000 OFF  
20101015_205057 rr 6.5 90 0 203420 1 500 1000 0.4 0.4 3 1415 77.7 H 15 1000 OFF  
20101015_205227 rr 6.5 90 0 203420 1 500 1000 0.4 0.4 3 1421 78.5 H 15 1000 OFF  
20101015_205359 rr 6.5 90 0 203420 1 500 1000 0.4 0.4 3 1420 78.4 H 15 1000 OFF  

Con disturbo si fa meglio di prima

TrackNo RefStar Mag El Wind Rec bin #mod freq gain mod nph SR band exp #frames disturb notes
20101015_221733 rr 6.4 90 0 203420 1 500 1000 0.5 0.5 3 1674 73.7 H 15 1000 ON  
20101015_221902 rr 6.4 90 0 203420 1 500 1000 0.5 0.5 3 1643 74.4 H 15 1000 ON  
20101015_222040 rr 6.4 90 0 203420 1 500 1000 0.5 0.5 3 1633 74.6 H 15 1000 ON  
20101015_222259 rr 6.3 90 0 203420 1 500 1000 0.0 0.0 3 1821 2.3 H 15 1000 ON OL per TF
20101015_222520 rr 6.3 90 0 203420 1 500 1000 0.0 0.0 3 1764 2.8 H 15 1000 ON  

KL_v7

La migliore base modale di sempre (FQP)

Ricostruttore a 500 modi a bin1, 3 lambda/D

Nuovo disturbo 201015_223914 550 modi, 3 frames, 1 ciclo, amp a mano 6 lambda div 1.5

Acquisizione intmat 3 lambda/D 48 iterazioni con loop chiuso 203420 (500modi, KL_v6), g=0.05 20101015_224425

Ricostruttore a 500 modi, skip 2, frame average 2, tilt removed 20101015_225912

TrackNo RefStar Mag El Wind Rec bin #mod freq gain mod nph SR band exp #frames disturb notes
20101015_230753 rr 6.5 90 0 225912 1 500 1000 0.3 0.4 3 1493 79.4 H 15 1000 OFF  
20101015_230930 rr 6.5 90 0 225912 1 500 1000 0.3 0.4 3 1513 79.4 H 15 1000 OFF  
20101015_231059 rr 6.5 90 0 225912 1 500 1000 0.3 0.4 3 1500 78.3 H 15 1000 OFF  

Caro FQP non e' meglio della v6!!! E perdi la scommessa, vegetali al manor house per te!

TrackNo RefStar Mag El Wind Rec bin #mod freq gain mod nph SR band exp #frames disturb notes
20101015_231655 rr 6.4 90 0 225912 1 500 1000 0.4 0.5 3 1634 71.6 H 15 1000 ON  
20101015_231830 rr 6.4 90 0 225912 1 500 1000 0.4 0.5 3 1636 71.9 H 15 1000 ON  
20101015_232106 rr 6.4 90 0 225912 1 500 1000 0.4 0.5 3 1617 73.6 H 15 1000 ON  

E con il disturbo mi fai pure quasi peggio.....

Ricostruttore a 500 modi a bin1, 2 lambda/D

Acquisizione intmat 2 lambda/D 48 iterazioni con loop chiuso 203420 (500modi, KL_v6), g=0.05 20101015_232754