Il bug del giorno e' la BCU39 incastrata che non manda slopes al secondario.

Si vede con il test_skip_frame() con WFSFrameCounter che sta fisso. La soluzione e' spengere tutto il W e ripartire.

Dobbiamo risolvere il problema della scarse performance a bin1.

TrackNo RefStar Mag El Wind Rec bin #mod freq gain mod nph SR band exp #frames notes
20101014_181004 rr 6.4 90 0 214405 1 399 1000 0.3 0.4 3 1630 -1.0 ? -1 -1  
20101014_181023 rr 6.4 90 0 214405 1 399 1000 0.3 0.4 3 1628 56.3 H 15 1000  
20101014_181304 rr 6.4 90 0 214405 1 399 1000 0.3 0.4 3 1611 56.2 H 15 1000  
20101014_181442 rr 6.4 90 0 214405 1 399 1000 0.3 0.4 3 1642 58.2 H 15 1000  
20101014_182123 rr 6.3 90 0 214405 1 399 1000 0.3 0.3 3 1728 61.6 H 15 1000  

Si decide di spengere la ventilazione nella tree house

TrackNo RefStar Mag El Wind Rec bin #mod freq gain mod nph SR band exp #frames notes
20101014_183819 rr 6.4 90 0 214405 1 399 1000 0.3 0.3 3 1646 75.9 H 15 1000  
20101014_183949 rr 6.4 90 0 214405 1 399 1000 0.3 0.3 3 1679 75.8 H 15 1000  
20101014_184157 rr 6.4 90 0 214405 1 399 1000 0.3 0.3 3 1668 77.0 H 15 1000  
20101014_184916 rr 6.4 90 0 214405 1 399 1000 0.1 0.1 3 1672 42.0 H 15 1000  
20101014_185145 rr 6.4 90 0 214405 1 399 1000 0.1 0.1 3 1637 45.4 H 15 1000  
20101014_185326 rr 6.4 90 0 214405 1 399 1000 0.3 0.3 3 1623 74.7 H 15 1000  
20101014_185459 rr 6.4 90 0 214405 1 399 1000 0.3 0.3 3 1588 75.3 H 15 1000  
20101014_190141 rr 6.4 90 0 214405 1 399 1000 0.3 0.3 3 1601 75.0 H 15 1000  

Problema risolto: queste sono le performance di giugno.

Ora si prova con il disturbo

Si carica il disturb /adopt_data/towerdata/adsec_calib/CMD/disturb/dist_atm_s0.8_L040.0_v15.0_ovfreq1000.00_sd829.fits

TrackNo RefStar Mag El Wind Rec bin #mod freq gain mod nph SR band exp #frames notes
20101014_193057 rr 6.4 90 0 214405 1 399 1000 0.4 0.4 3 1642 67.8 H 15 1000  
20101014_193224 rr 6.3 90 0 214405 1 399 1000 0.4 0.4 3 1729 68.4 H 15 1000  
20101014_193352 rr 6.4 90 0 214405 1 399 1000 0.4 0.4 3 1663 68.0 H 15 1000  

Anche qui le performance sono quelle di giugno

Bin2

TrackNo RefStar Mag El Wind Rec bin #mod freq gain mod nph SR band exp #frames notes
20101014_200649 rr 7.1 90 0 233633 2 153 991 0.3 0.4 3 3752 -1.0 ? -1 -1  
20101014_200706 rr 7.1 90 0 233633 2 153 991 0.3 0.4 3 3752 78.4 H 15 1000  
20101014_200830 rr 7.1 90 0 233633 2 153 991 0.3 0.4 3 3750 79.8 H 15 1000  
20101014_200951 rr 7.1 90 0 233633 2 153 991 0.3 0.4 3 3748 79.9 H 15 1000  

Con disturbo

Si carica il disturb /adopt_data/towerdata/adsec_calib/CMD/disturb/dist_atm_s0.8_L040.0_v15.0_ovfreq1000.00_sd829.fits

TrackNo RefStar Mag El Wind Rec bin #mod freq gain mod nph SR band exp #frames notes
20101014_202245 rr 7.0 90 0 233633 2 153 991 0.4 0.7 3 4090 47.0 H 15 1000  
20101014_202421 rr 7.0 90 0 233633 2 153 991 0.4 0.7 3 4084 48.1 H 15 1000  
20101014_202718 rr 7.0 90 0 233633 2 153 991 0.4 0.7 3 4073 46.4 H 15 1000  

Qui si fa un po' peggio

TrackNo RefStar Mag El Wind Rec bin #mod freq gain mod nph SR band exp #frames notes
20101014_204439 rr 7.0 90 0 233633 2 153 991 0.5 0.7 3 4021 49.8 H 15 1000  
20101014_204604 rr 7.0 90 0 233633 2 153 991 0.5 0.7 3 4015 51.1 H 15 1000  

Si abbassa la lampada perche' il 20100926_235114 fa il 55% e ha meno flusso

20101014_213545 rr 8.0 90 0 233633 2 153 991 0.4 0.7 3 1624 52.5 H 40 1000  
20101014_214526 rr 8.2 90 0 233633 2 153 991 0.4 0.7 3 1386 54.0 H 40 1000  
20101014_214725 rr 8.2 90 0 233633 2 153 991 0.4 0.7 3 1379 55.5 H 40 1000  

Ma la riprova non funziona!!

TrackNo RefStar Mag El Wind Rec bin #mod freq gain mod nph SR band exp #frames notes
20101014_215143 rr 6.8 90 0 233633 2 153 991 0.4 0.7 3 4946 55.3 H 15 1000  
20101014_220423 rr 6.7 90 0 233633 2 153 991 0.4 0.7 3 5176 51.1 H 15 1000  
20101014_220555 rr 6.7 90 0 233633 2 153 991 0.4 0.7 3 5166 51.6 H 15 1000  
20101014_220851 rr 6.7 90 0 233633 2 153 991 0.4 0.7 3 5150 52.7 H 15 1000  
20101014_221232 rr 6.7 90 0 233633 2 153 991 0.4 0.7 3 5130 52.9 H 15 1000  

Bin 3

Senza disturbo

TrackNo RefStar Mag El Wind Rec bin #mod freq gain mod nph SR band exp #frames notes
20101014_222521 rr 8.8 90 0 212832 3 65 900 0.3 0.3 5 1905 62.6 H 45 200  
20101014_222609 rr 8.8 90 0 212832 3 65 900 0.3 0.3 5 1920 60.1 H 45 200  