You are here: Foswiki>FLAO Web>LbtTel>LabLog20100623 (23 Jun 2010, EnricoPinna)Edit Attach

Montato retroreflector

Acquisizione IM 500modi 2l/D

=======================================

DISTURBOIM 20100623_045228
type = push-pull / sinusoidal /...>
Frames per mov = 3
Cycle = 1
Modes = KLv2
#Modes = 500
Amp = optimize_2lambda_630.fits
Note = <..............>

=======================================

=======================================

INTMATACQ 20100623_045644
Pup = 20100525_171742
Dist = 20100623_045228
Iteration = 24
Loop speed = 600
bin 1
Modul = 2l/D
Rec.Close loop
= 185716
Gain vector close loop = 0.05

=======================================

REC 20100623_050509
Modal Basis:Modes = KLv2
intmatacq = 20100623_045644
n modes = 500
cutted = 0
Note:con Tilt removal

=======================================

Ora proviamo ad abbassare le ampiezze

=======================================

DISTURBOIM 20100623_051201
type = push-pull / sinusoidal /...>
Frames per mov = 3
Cycle = 1
Modes = KLv2
#Modes = 500
Amp = optimize_amano6l_div1.5.fits
Note = <..............>

=======================================

INTMATACQ 20100623_051734
Pup = 20100525_171742
Dist = 20100623_051201
Iteration = 24
Loop speed = 600
bin 1
Modul = 2l/D
Rec.Close loop = 185716
Gain vector close loop = 0.05
Note: i rumori sono peggiorati e anche i modi sembrano peggiori
Le saturazioni sono peggio in questa, quindi le saturazioni sono dominate dalle

=======================================

REC 20100623_052423
Modal Basis:Modes = KLv2
intmatacq = 20100623_051734
n modes = 500
cutted = 0
Note:con Tilt remova, Non sembra buono

=======================================

Test del REC 20100623_050509

Senza disturbo

TrackNo RefStar Mag El Wind Rec bin #mod freq gain mod nph SR band exp #frames notes
20100623_053609 ??? 6.5 90 0 050509 1 500 1000 0.3 0.6 2 1498 60.9 H 20 500  
20100623_053705 ??? 6.5 90 0 050509 1 500 1000 0.3 0.6 2 1495 62.3 H 20 500  
20100623_053756 ??? 6.5 90 0 050509 1 500 1000 0.3 0.6 2 1500 61.3 H 20 500  
20100623_054038 ??? 6.5 90 0 050509 1 500 1000 0.3 0.6 2 1509 61.4 H 20 500  
20100623_054147 ??? 6.5 90 0 050509 1 500 1000 0.3 0.6 2 1509 60.4 H 20 500  
20100623_054238 ??? 6.5 90 0 050509 1 500 1000 0.3 0.6 2 1509 60.1 H 20 500  

Con disturbo 0.8"

TrackNo RefStar Mag El Wind Rec bin #mod freq gain mod nph SR band exp #frames notes
20100623_054455 ??? 6.5 90 0 050509 1 500 1000 0.4 0.6 2 1535 56.5 H 20 500  
20100623_054549 ??? 6.5 90 0 050509 1 500 1000 0.4 0.6 2 1533 56.4 H 20 500  
20100623_054644 ??? 6.5 90 0 050509 1 500 1000 0.4 0.6 2 1532 58.3 H 20 500  
20100623_054759 ??? 6.5 90 0 050509 1 500 1000 0.4 0.6 2 1531 55.9 H 20 500  

Per confronto proviamo con il vecchio REC 3l/d a 400modi 185716

Dobbiamo abbassare il gain
TrackNo RefStar Mag El Wind Rec bin #mod freq gain mod nph SR band exp #frames notes
20100623_055238 ??? 6.4 90 0 185716 1 400 1000 0.3 0.5 3 1551 64.8 H 20 500  
20100623_055342 ??? 6.4 90 0 185716 1 400 1000 0.3 0.5 3 1551 64.1 H 20 500  
20100623_055436 ??? 6.4 90 0 185716 1 400 1000 0.3 0.5 3 1551 65.2 H 20 500  
20100623_055533 ??? 6.4 90 0 185716 1 400 1000 0.3 0.5 3 1551 64.7 H 20 500  

Proviamo un KLv4 vecchio REC 221016

TrackNo RefStar Mag El Wind Rec bin #mod freq gain mod nph SR band exp #frames notes
20100623_055836 ??? 6.4 90 0 221016 1 400 1000 0.4 0.7 3 1553 58.4 H 20 500  
20100623_055948 ??? 6.4 90 0 221016 1 400 1000 0.4 0.7 3 1556 60.5 H 20 500  
20100623_060045 ??? 6.4 90 0 221016 1 400 1000 0.4 0.7 3 1557 59.7 H 20 500  
20100623_060159 ??? 6.4 90 0 221016 1 400 1000 0.4 0.7 3 1557 56.7 H 20 500  
20100623_060159 ??? 6.4 90 0 221016 1 400 1000 0.4 0.7 3 1557 56.7 H 20 500  

Proviamo un giuntato vecchio REC 013554

TrackNo RefStar Mag El Wind Rec bin #mod freq gain mod nph SR band exp #frames notes
20100623_060622 ??? 6.4 90 0 013554 1 400 1000 0.3 0.5 3 1556 66.7 H 20 500  
20100623_060739 ??? 6.4 90 0 013554 1 400 1000 0.3 0.5 3 1556 67.6 H 20 500  
20100623_060914 ??? 6.4 90 0 013554 1 400 1000 0.3 0.5 3 1556 66.6 H 20 500  
20100623_061011 ??? 6.4 90 0 013554 1 400 1000 0.3 0.5 3 1556 66.7 H 20 500  

Acquisiamo una matrice da 10 modi molto medita perche' il problema del 500 modi sembra nel TT

=======================================

DISTURBOIM 20100623_062144
type = push-pull
Frames per mov = 3
Cycle = 66
Modes = KLv2
#Modes = 10
Amp = optimize_2lambda_630.fits
Note = <..............>

=======================================

=======================================

INTMATACQ 20100623_062200
Pup = 20100525_171742
Dist = 20100623_062144
Iteration = 24
Loop speed = 600
bin 1
Modul = 2l/D
Rec.Close loop = 185716
Gain vector close loop = 0.05
Note:

=======================================

REC 20100623_062333
Modal Basis:Modes = KLv2
intmatacq = 20100623_051734
n modes = 10
cutted = 0
Note:

=======================================

REC 20100623_062438
Modal Basis:Modes = KLv2
intmatacq = 20100623_051734
n modes = 2
cutted = 0
Note:

=======================================

Ora giuntiamo le matrici

=======================================

REC 20100623_062825
Modal Basis:Modes = KLv2
intmatacq = 20100623_051734
n modes = 10+490
cutted = 0
Note: giuntato 20100623_050509+ 20100623_062333
problema di clocking fra 10 e 490, sono stati oresi cin differenza di 0.4deg

=======================================

Test del loop
TrackNo RefStar Mag El Wind Rec bin #mod freq gain mod nph SR band exp #frames notes
20100623_063307 ??? 6.5 90 0 062825 1 500 1000 0.3 0.6 2 1540 64.7 H 20 500  
20100623_063358 ??? 6.5 90 0 062825 1 500 1000 0.3 0.6 2 1540 67.9 H 20 500  
20100623_063454 ??? 6.5 90 0 062825 1 500 1000 0.3 0.6 2 1540 64.6 H 20 500  
20100623_063550 ??? 6.5 90 0 062825 1 500 1000 0.3 0.6 2 1540 64.4 H 20 500  
20100623_063749 ??? 6.5 90 0 062825 1 500 1000 0.3 0.6 2 1537 62.4 H 20 500 correzione clocking di 0.4deg
20100623_063847 ??? 6.5 90 0 062825 1 500 1000 0.3 0.6 2 1537 63.9 H 20 500 correzione clocking di 0.4deg
20100623_063939 ??? 6.5 90 0 062825 1 500 1000 0.3 0.6 2 1537 67.1 H 20 500 correzione clocking di 0.4deg
20100623_064224 ??? 6.4 90 0 062825 1 500 1000 0.3 0.6 2 1546 70.1 H 20 500 correzione clocking di 0.4deg

=======================================

REC 20100623_0629180
Modal Basis:Modes = KLv2
intmatacq = 20100623_051734
n modes = 2+498
cutted = 0
Note: giuntato 20100623_050509 +20100623_062438

=======================================
TrackNo RefStar Mag El Wind Rec bin #mod freq gain mod nph SR band exp #frames notes
20100623_064516 ??? 6.5 90 0 062918 1 500 1000 0.4 0.6 2 1535 -1.0 ? -1 -1  
20100623_064536 ??? 6.5 90 0 062918 1 500 1000 0.4 0.6 2 1535 -1.0 ? -1 -1  
20100623_064605 ??? 6.5 90 0 062918 1 500 1000 0.4 0.6 2 1535 -1.0 ? -1 -1  
20100623_064627 ??? 6.5 90 0 062918 1 500 1000 0.4 0.6 2 1535 64.8 H 20 500  
20100623_064724 ??? 6.5 90 0 062918 1 500 1000 0.4 0.6 2 1535 65.8 H 20 500  
20100623_064822 ??? 6.5 90 0 062918 1 500 1000 0.4 0.6 2 1534 69.5 H 20 500  
20100623_064941 ??? 6.5 90 0 062918 1 500 1000 0.4 0.6 2 1532 66.6 H 20 500  
20100623_065042 ??? 6.5 90 0 062918 1 500 1000 0.4 0.6 2 1533 68.8 H 20 500  

Acquisiamo IM 500 modi a 3 l/D

=======================================

DISTURBOIM 20100623_074229
type = push-pull / sinusoidal /...>
Frames per mov = 3
Cycle = 1
Modes = KLv2
#Modes = 500
Amp = optimize_amano6l.fits
Note = <..............>

=======================================

INTMATACQ 20100623_074241
Pup = 20100525_171742
Dist = 20100623_074229
Iteration = 24
Loop speed = 600
bin 1
Modul = 3l/D
Rec.Close loop = 185716
Gain vector close loop = 0.05
Note:

=======================================

REC 20100623_075152
Modal Basis:Modes = KLv2
intmatacq = 20100623_074241
n modes = 500
cutted = 0
Note:

=======================================

Ora prenidamo i 10 modi per giuntare

=======================================

DISTURBOIM 20100623_075458
type = push-pull / sinusoidal /...>
Frames per mov = 3
Cycle = 66
Modes = KLv2
#Modes = 10
Amp = optimize_amano6l.fits
Note = <..............>

=======================================

INTMATACQ 20100623_075508
Pup = 20100525_171742
Dist = 20100623_075458
Iteration = 4
Loop speed = 600
bin 1
Modul = 3l/D
Rec.Close loop = 185716
Gain vector close loop = 0.05
Note:

=======================================

REC 20100623_075707
Modal Basis:Modes = KLv2
intmatacq = 20100623_074241
n modes = 10
cutted = 0
Note:

=======================================

Calibrazione del TT drizlilng sul CCD47

1kHz

TrackNo RefStar Mag El Wind Rec bin #mod freq gain mod nph SR band exp #frames TTosset
20100623_080838 ??? 6.9 90 0 062918 1 500 1000 0.4 0.6 2 1061 -1.0 ? -1 -1 0
20100623_081112 ??? 6.9 90 0 062918 1 500 1000 0.4 0.6 2 1067 -1.0 ? -1 -1 X=+2V
20100623_081302 ??? 6.9 90 0 062918 1 500 1000 0.4 0.6 2 1063 -1.0 ? -1 -1 X=-2V
20100623_081426 ??? 6.9 90 0 062918 1 500 1000 0.4 0.6 2 1065 -1.0 ? -1 -1 Y+2V
20100623_081537 ??? 6.9 90 0 062918 1 500 1000 0.4 0.6 2 1065 -1.0 ? -1 -1 Y=-2V
20100623_081641 ??? 6.9 90 0 062918 1 500 1000 0.4 0.6 2 1061 -1.0 ? -1 -1 X=+1V

100Hz

TrackNo RefStar Mag El Wind Rec bin #mod freq gain mod nph SR band exp #frames notes
20100623_082140 ??? 9.0 90 0 185716 1 400 100 0.4 2.0 -9999 1414 -1.0 ? -1 -1 0
20100623_082245 ??? 9.0 90 0 185716 1 400 100 0.4 2.0 -9999 1437 -1.0 ? -1 -1 x=+2V
20100623_082341 ??? 9.1 90 0 185716 1 400 100 0.4 2.0 -9999 1392 -1.0 ? -1 -1 x=-2V

Misura della pixelscale del CCD47 con nasello e filtro 850nm

TrackNo RefStar Mag El Wind Rec bin #mod freq gain mod nph SR band exp #frames stage pos(x,y)
20100623_082709 ??? 9.2 90 0 185716 1 400 100 -1.0 -1.0 -9999 1281 -1.0 ? -1 -1 -75.002;35.346
20100623_082933 ??? 9.5 90 0 185716 1 400 100 -1.0 -1.0 -9999 937 -1.0 ? -1 -1 -79.000; 35.346
20100623_083130 ??? 9.5 90 0 185716 1 400 100 -1.0 -1.0 -9999 943 -1.0 ? -1 -1 -72.503;35.346
20100623_083305 ??? 9.5 90 0 185716 1 400 100 -1.0 -1.0 -9999 937 -1.0 ? -1 -1 -75.002;33.013
20100623_083454 ??? 9.5 90 0 185716 1 400 100 -1.0 -1.0 -9999 935 -1.0 ? -1 -1 -75.002;38.514

Test della matrice 3l/Da 500 modi

TrackNo RefStar Mag El Wind Rec bin #mod freq gain mod nph SR band exp #frames notes

20100623_084141 ??? 6.0 90 0 075152 1 500 1000 0.3 0.4 2 2429 64.3 H 20 500  
20100623_084234 ??? 6.0 90 0 075152 1 500 1000 0.3 0.4 2 2402 61.2 H 20 500  
20100623_084328 ??? 6.0 90 0 075152 1 500 1000 0.3 0.4 2 2414 63.9 H 20 500  
20100623_084421 ??? 6.6 90 0 075152 1 500 1000 0.3 0.4 2 1408 66.3 H 20 500  
20100623_084655 ??? 6.5 90 0 075152 1 500 1000 0.3 0.4 2 1432 67.3 H 20 500  
20100623_084750 ??? 6.6 90 0 075152 1 500 1000 0.3 0.4 2 1404 62.5 H 20 500  
20100623_084857 ??? 6.5 90 0 075152 1 500 1000 0.3 0.4 2 1438 65.4 H 20 500  
20100623_085427 ??? 6.5 90 0 075152 1 500 1000 0.4 0.4 2 1477 52.2 H 20 500  

Proviamo con i guadagni modali