Led On

Dome Light off

Dave and Marco in control room

Enrico and Carmelo in "control room" Arcetri

Simone videoconferencing with control room LBT and carefully maniging the operations

Adjusting Little Joe temperatures to have a correc set of the voltages

Taking a dark

BOARD SETUP first_star_light2:

-75. +35.47, checked

100Hz

Positiioning cube in home position

Switching off the flower pot

Now we can see LED

Taking a new dark for CCD39

Waiting for a second dark

Warning in the DARK procedure: cannot communicate with lamp

Switching on the lamp..

Taking a new dark for CCD39

Warning again

Saving a configuration board setup: first_star_light3

Non ci piace che spegnendo la flower pot e riaccendendo

il sistema non comunica piĆ¹ con gli elementi all'interno della flower pot stessa

But the peak controller was bad and now is good

Now is loading the board configuration correctly.

In principle would be enough to restart the process of the peack flower pot.

When we switched off the flower pot this process was down correctly, but switching on the flower pot this process didn't restart.

We turn off the lamp.

On the BoardGui the modulation shown is wrong!

Camera Lens to Y=-12 and X = -24

DeRotator 173.1, Rotator 0.

Correcting camera lens position.

New camera lens positions:

Y=-12 , X = +20

Commento: the gui was better with VNC

Checking LED position with respect to the reference pupil mask.

Taking a new dark

Taking Frames:

Now everything is on.

We adjust from the arbitrator window the loop parameters.

BINNING 1

Freq 100

Modulatio 2 lambda su D

ZENIT POSITION (ALT = 90 DEG): 20100430_

091030 AGW ROTATOR 0 DEG 0ARCSEC

091246 AGW ROTATOR 20 DEG 72000ARCSEC

091410 AGW ROTATOR 40 DEG 144000ARCSEC

091509 AGW ROTATOR 60 DEG ARCSEC (led verticals!)

091620 AGW ROTATOR 80 DEG 288000ARCSEC

091708 AGW ROTATOR 100 DEG 360000ARCSEC

091850 AGW ROTATOR 120 DEG

RIPRENDIAMO UN DARK. THERE WAS A DRIFT OF -50.

092110 AGW ROTATOR 140 DEG (504000 ARCSEC)

092217 AGW ROTATOR 160 DEG

092338 AGW ROTATOR 180 DEG

092502 AGW ROTATOR 200 DEG

RIPRENDIAMO UN DARK. THERE WAS A DRIFT OF -25.

092654 AGW ROTATOR 220 DEG

092814 AGW ROTATOR 240 DEG

RIPRENDIAMO UN DARK. THERE WAS A POSITIVE DRIFT OF 30.

092953 AGW ROTATOR 260 DEG

093033 AGW ROTATOR 280 DEG

093205 AGW ROTATOR 300 DEG

093341 AGW ROTATOR 320 DEG

093424 AGW ROTATOR 340 DEG

093501 AGW ROTATOR 360 DEG


FW1 = mirror

Mirror in front of the incoming light as filter

093501 agw rotator off

MOVING from 360 to 0 the AGW ROTATOR

093753 moving agw rotator

093804 moving agw rotator

093816 moving agw rotator

093834 moving agw rotator

093846 moving agw rotator

093858 moving agw rotator

AGW ROTATOR at 0!

Moving the telescope at 60 Altitude

Filter wheel: empty

AGW Rotator at 0!

094219 AGW ROTATOR 0 DEG 0ARCSEC

094308 AGW ROTATOR 20 DEG 72000ARCSEC

094417 AGW ROTATOR 40 DEG

094523 AGW ROTATOR 60 DEG 216000Arcsec

094615 AGW ROTATOR 80 DEG

094708 AGW ROTATOR 100 DEG

094800 AGW ROTATOR 120 DEG

094845 AGW ROTATOR 140 DEG

094932 AGW ROTATOR 160 DEG

095023 AGW ROTATOR 180 DEG

095124 AGW ROTATOR 200 DEG

095222 AGW ROTATOR 220 DEG

095319 AGW ROTATOR 240 DEG

095445 AGW ROTATOR 260 DEG

095524 AGW ROTATOR 280 DEG

095614 AGW ROTATOR 280 DEG

095711 AGW ROTATOR 300 DEG

095802 AGW ROTATOR 320 DEG

095850 AGW ROTATOR 340 DEG

095946 AGW ROTATOR 360 DEG

Rotator is going to 0, noise measurements

Filter Wheel: Mirror

100108 moving agw rotator (PS: MISSING FILES, CARMELO)

PIC RESET after 180deg (probably) towards 0...

PROBLEM: WFS arbitrator doesn't start
Alfio identified the problem

Test Rerotator (on board W) with ADSEC LEDs

Test con muovileggirotatore 20100430_102910
Telescope 30deg form Zenith
AGW Derotator = 0deg

Test con muovileggirotatore 20100430_104603
Telescope 45deg form Zenith
AGW Derotator = 0deg

DARK CCD39 ACQUIRED

Test con muovileggirotatore 20100430_105120
Telescope 15deg form Zenith
AGW Derotator = 0deg

Test con muovileggirotatore 20100430_105504
Telescope 0deg form Zenith
AGW Derotator = 0deg

DARK CCD39 ACQUIRED

Test con muovileggirotatore 20100430_110731
Telescope 0deg form Zenith
AGW Derotator = 180deg

DARK CCD39 ACQUIRED

Test con muovileggirotatore 20100430_111540
Telescope 30deg form Zenith
AGW Derotator = 180deg

CCD39 RON WHILE TELESCOPE TRACKING

Telescope 30deg form Zenith
AGW Derotator = 270deg + tracking
Hexapod: 2.5 -3.6 1.77 -360 -120 0

ccd39 frames @100Hz 20100430_112357

ccd39 frames @1000Hz 20100430_112529

ccd39 frames @1000Hz 20100430_112607

TEST REROTATION WITH LEDs WHILE Tacking

ELEVATION 75.1

AZIMUTH 161.9

114158 AGW ROTATOR 197 REROTATOR 261

114523 AGW ROTATOR 195.1 REROTATOR 262

114727 RON MEASUREMENTS 1000frames

114759 RON MEASUREMENTS 1000frames

114858 RON MEASUREMENTS 1000frames

115015 AGW ROTATOR 191 REROTATOR 264

115210 AGW ROTATOR 189 REROTATOR

115444 AGW ROTATOR 187 REROTATOR

ELEVATION 75.48

AZIMUTH 175.16

115731 AGW ROTATOR 185 REROTATOR

ccd39DARK

120050 AGW ROTATOR 182 REROTATOR 269

120313 RON test in condizioni di tracking: AGW in tracking e pupil rerotator che insegue. (PS: MISSING FILES, CARMELO)

120732 RON test con FW off, flowerpot OFF, LJ47 OFF.(PS: MISSING FILES, CARMELO)

121132 AGW ROTATOR 173 REROTATOR 273

-- Main.mrEnricoPinna - 30 Apr 2010

I Attachment Action Size Date Who CommentSorted ascending
Trackinga.epseps Trackinga.eps manage 18 K 03 May 2010 - 16:44 CarmeloArcidiacono  
Trackingb.epseps Trackingb.eps manage 19 K 03 May 2010 - 16:44 CarmeloArcidiacono  
Z0deg.Wrot0degb.epseps Z0deg.Wrot0degb.eps manage 28 K 04 May 2010 - 16:33 CarmeloArcidiacono  
Z0deg.Wrot180degb.epseps Z0deg.Wrot180degb.eps manage 28 K 04 May 2010 - 16:34 CarmeloArcidiacono  
Z15deg.Wrot0degb.epseps Z15deg.Wrot0degb.eps manage 28 K 04 May 2010 - 16:33 CarmeloArcidiacono  
Z30deg.Wrot0degb.epseps Z30deg.Wrot0degb.eps manage 28 K 04 May 2010 - 16:33 CarmeloArcidiacono  
Z30deg.Wrot180degb.epseps Z30deg.Wrot180degb.eps manage 29 K 04 May 2010 - 16:34 CarmeloArcidiacono  
Z45deg.Wrot0degb.epseps Z45deg.Wrot0degb.eps manage 29 K 05 May 2010 - 14:50 CarmeloArcidiacono  
Z45deg.Wrot0degbNEW.epseps Z45deg.Wrot0degbNEW.eps manage 29 K 05 May 2010 - 14:52 CarmeloArcidiacono  
Zen0a.epseps Zen0a.eps manage 17 K 03 May 2010 - 16:33 CarmeloArcidiacono  
Zen0b.epseps Zen0b.eps manage 26 K 03 May 2010 - 16:33 CarmeloArcidiacono  
Zen30a.epseps Zen30a.eps manage 19 K 03 May 2010 - 16:33 CarmeloArcidiacono  
Zen30b.epseps Zen30b.eps manage 26 K 03 May 2010 - 16:33 CarmeloArcidiacono  
centers_rotator.epseps centers_rotator.eps manage 23 K 04 May 2010 - 16:36 CarmeloArcidiacono  
centers_rotatorNEW.epseps centers_rotatorNEW.eps manage 23 K 05 May 2010 - 14:52 CarmeloArcidiacono  
FLAO_on_sky_test_report_for_observing_nights_28th.rtfrtf FLAO_on_sky_test_report_for_observing_nights_28th.rtf manage 3 MB 07 May 2010 - 16:30 CarmeloArcidiacono Bozza!
Tracking.epseps Tracking.eps manage 112 K 03 May 2010 - 16:44 CarmeloArcidiacono Done By circle Fitting
Zen0.epseps Zen0.eps manage 247 K 03 May 2010 - 16:32 CarmeloArcidiacono Done By circle Fitting
Zen30.epseps Zen30.eps manage 259 K 03 May 2010 - 16:33 CarmeloArcidiacono Done By circle Fitting
Topic revision: r8 - 07 May 2010, CarmeloArcidiacono
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding Foswiki? Send feedback